Siemens

Siemens SITRANS FM MAG 1100 F Flow Sensor (7ME6140-2DA22-2AA1)

SKU 7ME6140-2DA22-2AA1

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Siemens
  • Product No.: 7ME6140-2DA22-2AA1
  • Origin Germany
  • Product Type: Flow Sensors
  • Barcode: 85389091
  • Payment: T/T, Western Union
  • Weight: 5.2 kg
  • Dimensions: 30.50cm x 26.50cm x 21.00cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

The SITRANS FM MAG 1100 F is a full-bore electromagnetic flow sensor specifically engineered for the food, beverage, and pharmaceutical industries. This 7ME6140-2DA22-2AA1 model features a robust sanitary design suitable for measuring the volume flow of conductive liquids. It is built with a ceramic liner and Platinum electrodes, ensuring exceptional chemical resistance and durability in clean-in-place (CIP) and steam-in-place (SIP) processes. As a sensor designed for remote mounting, it provides high-precision measurement while allowing the transmitter to be located in a separate, more accessible area.

Features

  • Sanitary Construction: Designed for high-hygiene applications in F&B and pharmaceutical sectors.
  • Material Integrity: Ceramic liner with FDA-compliant FPM/FKM gaskets and Platinum electrodes for superior resistance to aggressive media.
  • Full-Bore Design: No moving parts, minimizing pressure loss and maintenance requirements.
  • Remote Compatibility: Optimized for use with remote SITRANS FM transmitters.
  • Operational Versatility: Suitable for DN25 (1 inch) piping systems.

Applications

  • Food and beverage production (e.g., dairy, juice, beverage bottling)
  • Pharmaceutical manufacturing (e.g., batch processing, dosing)
  • High-hygiene chemical processing
  • Conductive liquid flow measurement

Technical Specifications

Attribute Specification
Manufacturer Siemens
Range SITRANS
Model 7ME6140-2DA22-2AA1
Diameter DN25 (1 inch)
Liner Material Ceramic
Electrode Material Platinum
Seal Material FPM/FKM (FDA compliant)
Weight 5.20kg
Dimensions 30.50 x 26.50 x 21.00 cm
PLM Product Phase Active

Installation Guidelines

  • Mounting: Ensure the sensor is installed in a pipeline section where the pipe is always completely filled with the liquid to prevent measurement errors.
  • Orientation: Install the sensor in a vibration-free location, ideally with a straight pipe run of at least 3x the diameter upstream and 2x downstream.
  • Grounding: Proper grounding is critical for electromagnetic flowmeters; ensure grounding rings or electrodes are used if the piping material is non-conductive.
  • Hygiene Compliance: Since this model is "not 3A approved," verify it meets the specific sanitary requirements and local regulations for your process environment before installation.
  • Remote Integration: Mount the remote transmitter within the cable length limitations specified for the sensor to maintain signal integrity.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What industries is the MAG 1100 F sensor designed for?
It is specifically designed for the food, beverage, and pharmaceutical industries where sanitary conditions are required.
Is this a compact or remote-style sensor?
This is a sensor for a remote transmitter; the transmitter must be ordered separately.
What are the electrode and liner materials?
The sensor uses Platinum electrodes and a Ceramic liner.
Does this model carry 3A approval?
No, this specific configuration is not 3A approved.
Reviews

7ME6140-2DA22-2AA1

Stock & lead time on request

Call
1 su 1

Siemens SITRANS FM MAG 1100 F Flow Sensor (7ME6140-2DA22-2AA1)

Only 6 item(s) left in stock
  • Manufacturer: Siemens

  • Product No.: 7ME6140-2DA22-2AA1

  • Country of origin:Germany

  • Product Type: Flow Sensors

  • Barcode: 85389091

  • Payment: T/T, Western Union

  • Weight: 5200g

  • Dimensions: 30.50cm x 26.50cm x 21.00cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The SITRANS FM MAG 1100 F is a full-bore electromagnetic flow sensor specifically engineered for the food, beverage, and pharmaceutical industries. This 7ME6140-2DA22-2AA1 model features a robust sanitary design suitable for measuring the volume flow of conductive liquids. It is built with a ceramic liner and Platinum electrodes, ensuring exceptional chemical resistance and durability in clean-in-place (CIP) and steam-in-place (SIP) processes. As a sensor designed for remote mounting, it provides high-precision measurement while allowing the transmitter to be located in a separate, more accessible area.

Features

  • Sanitary Construction: Designed for high-hygiene applications in F&B and pharmaceutical sectors.
  • Material Integrity: Ceramic liner with FDA-compliant FPM/FKM gaskets and Platinum electrodes for superior resistance to aggressive media.
  • Full-Bore Design: No moving parts, minimizing pressure loss and maintenance requirements.
  • Remote Compatibility: Optimized for use with remote SITRANS FM transmitters.
  • Operational Versatility: Suitable for DN25 (1 inch) piping systems.

Applications

  • Food and beverage production (e.g., dairy, juice, beverage bottling)
  • Pharmaceutical manufacturing (e.g., batch processing, dosing)
  • High-hygiene chemical processing
  • Conductive liquid flow measurement

Technical Specifications

Attribute Specification
Manufacturer Siemens
Range SITRANS
Model 7ME6140-2DA22-2AA1
Diameter DN25 (1 inch)
Liner Material Ceramic
Electrode Material Platinum
Seal Material FPM/FKM (FDA compliant)
Weight 5.20kg
Dimensions 30.50 x 26.50 x 21.00 cm
PLM Product Phase Active

Installation Guidelines

  • Mounting: Ensure the sensor is installed in a pipeline section where the pipe is always completely filled with the liquid to prevent measurement errors.
  • Orientation: Install the sensor in a vibration-free location, ideally with a straight pipe run of at least 3x the diameter upstream and 2x downstream.
  • Grounding: Proper grounding is critical for electromagnetic flowmeters; ensure grounding rings or electrodes are used if the piping material is non-conductive.
  • Hygiene Compliance: Since this model is "not 3A approved," verify it meets the specific sanitary requirements and local regulations for your process environment before installation.
  • Remote Integration: Mount the remote transmitter within the cable length limitations specified for the sensor to maintain signal integrity.

What industries is the MAG 1100 F sensor designed for?

It is specifically designed for the food, beverage, and pharmaceutical industries where sanitary conditions are required.

Is this a compact or remote-style sensor?

This is a sensor for a remote transmitter; the transmitter must be ordered separately.

What are the electrode and liner materials?

The sensor uses Platinum electrodes and a Ceramic liner.

Does this model carry 3A approval?

No, this specific configuration is not 3A approved.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...