Mitsubishi Electric LJ71E71-100-CM MELSEC L Series Ethernet Interface Module

Mitsubishi Electric LJ71E71-100-CM MELSEC L Series Ethernet Interface Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: LJ71E71-100-CM

  • Country of origin:United States

  • Product Type: PLC Communication Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 130 mm x 110 mm x 45 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Providing high-speed Ethernet connectivity directly to MELSEC L Series architectures, the Mitsubishi Electric LJ71E71-100-CM manages robust plant-level data transmission and programming tasks. This module enables fast, reliable industrial network communications by acting as a gateway between the processor unit and supervisor-level SCADA systems, HMIs, or other controllers. Featuring dual-rate physical media support for 100BASE-TX and 10BASE-T networks, the module seamlessly processes intensive data payloads while maintaining low internal bus current draw. Built-in system functions allow for easy remote maintenance, diagnostic monitoring, and configuration changes directly through the GX Works2 programming software platform.

Features

  • Multi-Protocol Support: Compatible with MELSOFT connection, SLMP (MC protocol), Socket communication, and pre-defined developer protocols.
  • Flexible Network Access: Built-in Web functions and E-mail transmission utilities allow for direct remote troubleshooting and diagnostics.
  • Auto-Negotiation: Built-in transceiver automatically adjusts between 100 Mbps and 10 Mbps operational speeds depending on the network switch environment.
  • Compact L-Series Form Factor: Integrates directly onto the L-Series DIN-rail mount system without requiring a bulky dedicated base unit.

Applications

  • Distributed industrial control networks linking multiple PLC systems across large manufacturing plants.
  • Real-time communication and variables transmission between PLC units and HMI/SCADA management interfaces.
  • Remote programming, diagnostic monitoring, and automated alarm notification via standard email services.

Technical Specifications

Manufacturer Mitsubishi Electric
Model Number LJ71E71-100-CM
Product Series MELSEC L Series
Module Type Ethernet Interface Module
Data Transmission Speed 100 Mbps (100BASE-TX) / 10 Mbps (10BASE-T)
Communication Port Type RJ45 female connector
Internal Current Consumption (5 VDC) 0.60 A
Max Simultaneous Connections 16 connections
Shipping Weight (Calculated) 0.45 kg
Package Dimensions (Calculated) 130 mm x 110 mm x 45 mm

Connections and Interfaces

Connector Pin Function / Assignment
Pin 1 TX+ (Transmit Data +)
Pin 2 TX- (Transmit Data -)
Pin 3 RX+ (Receive Data +)
Pin 6 RX- (Receive Data -)

Empirical Engineering Insights

Alternative Models & Compatibility

The LJ71E71-100-CM is physically and functionally drop-in compatible with standard MELSEC L Series CPU systems. The "-CM" suffix indicates regional industrial standard compliance configurations, though identical Ethernet configurations apply inside GX Works2. In legacy migrations, verify your CPU unit firmware supports multi-connection network interfaces before integrating this module to prevent communication timeout faults.

Application Pitfalls & Engineering Notes

When adding the Ethernet module to an active L-Series CPU stack, recalculate your internal 5 VDC system bus current draw. This unit draws a constant 0.60 A. If combined with multiple positioning modules or high-density digital I/O blocks, you may exceed the current supply limit of standard power modules (such as the L61P or L63P), which can cause random CPU lockups or system reset faults.

Commissioning & Wiring Tips

To prevent high-frequency EMI noise from adjacent high-voltage machinery or VFD cabling from disrupting network communication packets, always use Category 5e (or higher) double-shielded twisted pair (STP) cables. Securely connect the cable shielding mesh directly to the system's protective ground bus and establish a single-point earth ground for the rack assembly.

Installation Guidelines

CRITICAL WARNING

Disconnect all external power sources supplying the PLC system and network interfaces before inserting, removing, or wiring the communication module. Failure to completely de-energize the assembly can cause permanent backplane circuit damage, microprocessor failure, or unpredictable system behavior.

1

Align the module's locking hook with the adjacent CPU module or base unit connector slot on the DIN rail.

2

Press the modules together until they click firmly, and securely engage the mechanical locking levers at the top and bottom of the unit.

3

Insert the RJ45 industrial Ethernet cable into the front communication port, ensuring the locking clip latches securely.

4

Apply power and verify that the front panel LED indicators display "RUN" and the Link/Speed indicators flash on network activity.

Does the LJ71E71-100-CM support MC Protocol?

Yes, it fully supports SLMP (Seamless Message Protocol) and MC Protocol (Format 1C/3C/4C) for communication with host computers, HMI, SCADA systems, and other PLCs.

What is the internal 5 VDC bus power consumption of this module?

The module draws 0.60 A from the internal 5 VDC system bus. Calculate your total power budget to ensure the L-Series power supply module is not overloaded.

Does this communication module require high-speed configuration programs?

No, parameter configuration, routing tables, and email services are parameterized inside GX Works2 software, avoiding complex manual programming.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Сұйықтық қуат жүйелерін ауыстыруға арналған электрлік актуаторлар: Практикалық өнеркәсіптік автоматтандыру нұсқаулығы

Бұл мақала SMC компаниясының e-Actuator сериясы сияқты біріктірілген электрлік актюаторлардың дәстүрлі пневматикалық және гидравликалық жүйелерді ауыстыра отырып, өнеркәсіптік қозғалысты басқаруды...

Өнеркәсіптік автоматтандыру қолданбалары үшін OpenPLC көмегімен математикалық операциялар

Бұл мақалада PLC жүйелерінің өнеркәсіптік автоматтандыруда қосу, алу, көбейту, бөлу, модуль және дәрежелеу сияқты негізгі математикалық операцияларды қалай орындайтыны түсіндіріледі. Онда осы функция...

FBD PLC бағдарламалауындағы жетілдірілген булев логика: Негізгі логикадан тыс практикалық өнеркәсіптік қолданбалар

Мақалада PLC бағдарламалауында негізгі AND, OR және NOT операцияларынан тыс қолданылатын бірнеше күрделі Булев логика функциялары түсіндіріледі. Онда шындық кестелері, мультиплексорлар, импульс...

PLC бағдарламалаудағы логикалық операторлар: FBD логикалық қақпаларын түсіну

Булев логика әрбір ПЛК бағдарламасының негізі болып табылады. Қарапайым машина басқару жүйелерінен күрделі өнеркәсіптік автоматтандыру жүйелеріне дейін, логикалық қақпалар контроллерлердің өзгеретін...