Description

Executing local control logic while maintaining high-speed fieldbus communications, the BECKHOFF BC7300 serves as a decentralized programmable controller that seamlessly bridges serial Modbus networks and modular I/O terminals. This compact controller integrates a complete PLC runtime system conforming to IEC 61131-3, allowing local preprocessing of signals independent of the master control system. Capable of hosting up to 64 Bus Terminals, the device optimizes distributed topologies by managing up to 256 digital or 128 analog inputs and outputs directly on the K-bus assembly.

The integrated RS485 D-sub interface supports both Modbus RTU and ASCII protocols, facilitating straightforward integration into legacy SCADA, DCS, or third-party PLC architectures. Configured using TwinCAT programming environments, the device features robust electrical isolation and a dedicated internal power supply to drive connected terminal modules reliably under harsh industrial conditions.

Features

  • Local Intelligence: Built-in PLC runtime system executes 1 PLC task with a cycle time of approximately 3 ms per 1,000 instructions.
  • Flexible Address Configuration: Address settings and operating modes can be adjusted directly via integrated rotary switches or KS2000 software.
  • High I/O Capacity: Supports direct connection of up to 64 Beckhoff Bus Terminals (K-bus expansion).
  • Dual Protocol Support: Configurable for either Modbus RTU or Modbus ASCII serial communication protocols.
  • Substantial Local Memory: Equipped with 32/96 KB of program memory and 32/64 KB of data memory, alongside 512 bytes of remanent data storage.
  • Industrial Protection: Features 500 V electrical isolation between the power contacts, supply voltage, and the fieldbus interface.

Applications

  • Decentralized manufacturing automation lines requiring local preprocessing.
  • Remote Terminal Unit (RTU) deployments in infrastructure, water, and wastewater systems.
  • HVAC and building automation networks utilizing serial Modbus RTU protocols.
  • Substation monitor systems requiring localized signal conditioning and processing.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model Number BC7300
Fieldbus Interface D-sub 9-pin, RS485
Supported Protocols Modbus RTU, Modbus ASCII (Default: RTU)
Data Transfer Rates 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 baud
Programming Software TwinCAT (via programming interface or fieldbus)
Program Memory 32 / 96 kbytes
Data Memory 32 / 64 kbytes
Remanent Data 512 bytes
K-Bus Current Supply 1750 mA
Power Contacts Max. 24 V DC / Max. 10 A
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
ATEX Ex Marking II 3 G Ex nA IIC T4 Gc
Physical Dimensions 51 mm x 100 mm x 69 mm
Product Weight 170 g
Shipping Weight (Calculated) 3.0 kg (with heavy-duty industrial protective packaging)

Connections and Interfaces

D-sub 9-Pin Pinout Signal Designation Description
Pin 3 RxD/TxD-B (+) Transmit / Receive Data (Positive)
Pin 8 RxD/TxD-A (-) Transmit / Receive Data (Negative)
Pin 5 GND Signal Ground Reference
Pin 1 Shield Functional Earth / Shield Connection

Empirical Engineering Insights

Alternative Models & Compatibility

While the BC7300 targets serial Modbus RTU/ASCII applications, systems transitioning to Ethernet infrastructures should consider the BC9000 (Modbus/TCP). When upgrading legacy setups, ensure that the TwinCAT target system configuration matches the target BC architecture, as compiling for BK-type couplers is incompatible with BC programmable controllers.

Application Pitfalls & Engineering Notes

The BC7300 features a maximum K-Bus current supply capacity of 1750 mA. When configuring a dense physical node with multiple analog or special function terminals, calculate the cumulative current consumption of all modules. If the requirements exceed 1750 mA, you must integrate intermediate power feed terminals (such as the KL9110 or KL9210) to prevent dropouts on the internal bus.

Commissioning & Wiring Tips

Always verify that the termination resistor on the Modbus RS485 physical line is correctly switched or wired. Because the BC7300 reads rotary switch station addresses only during its initial boot phase, any physical modifications made to the node address while powered will not take effect until the device undergoes a complete power cycle.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate all electrical power sources before initiating hardware installation, wire termination, or terminal block removal. Failure to de-energize primary supply circuits and physical contacts can result in permanent equipment damage, short circuits, or electrical shock hazards to commissioning engineers.

1 Mount the BC7300 controller firmly onto a standard 35 mm DIN rail (conforming to EN 60715) until the rear locking mechanism fully engages.
2 Slide adjacent Beckhoff Bus Terminals onto the rail from right to left, utilizing the integrated double slot and key connection for reliable structural alignment.
3 Terminate field wiring into the cage clamp terminals using a flat-head screwdriver to actuate the spring tension mechanism. Strip conductors strictly to 8–9 mm.
4 Connect the RS485 Modbus serial line via the D-sub 9-pin interface. Ensure that proper shielding is maintained and grounded at a single, centralized earth point.
Loading product navigation…

What software is required to program the BC7300?

The BC7300 is programmed using TwinCAT 2 in compliance with the IEC 61131-3 standard. Programming can be done through the serial configuration interface or over the fieldbus network.

What is the maximum K-bus current supplied by the controller?

The BC7300 supplies up to 1750 mA to the connected Bus Terminals. If your specific I/O configuration requires more current, you must insert a power feed terminal such as the KL9110 or KL9210.

How do you set the station address on the BC7300?

The Modbus station address is configured via the integrated rotary address switches on the controller housing, or it can be configured via the KS2000 configuration software. Address modifications require a power cycle to take effect.

Does the BC7300 support Modbus RTU and ASCII protocols?

Yes. The controller supports both Modbus RTU and Modbus ASCII. Modbus RTU is the factory default protocol.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...