Description

Designed for decentralized automation setups, the Beckhoff EP1518-0002 serves as an IP67-rated EtherCAT Box that integrates eight digital inputs into a rugged, cabinet-free housing. This compact module is optimized for direct machine mounting, eliminating the need for protective enclosures. Two of the eight inputs are highly versatile, supporting configuration as 32-bit up/down counters to handle pulse processing. The module fully integrates with EtherCAT networks, using Distributed Clocks (DC) to ensure high-precision temporal synchronization across the plant floor.

Features

  • Digital Inputs: 8 digital inputs with adjustable filter times from 0 to 100 ms to eliminate signal noise.
  • Counter Functionality: 2 inputs configurable as 32-bit up/down counters with a maximum input frequency of 1 kHz.
  • Precise Synchronization: Built-in Distributed Clocks (DC) support for deterministic network timing.
  • Robust Protection: Fully encapsulated IP65/66/67-rated housing resistant to moisture, dust, and vibration.
  • Integrated Sensor Supply: Short-circuit-proof sensor power supply, delivering up to 0.5 A per group of 4 sensors.
  • Standardized Connections: Standardized M12 and M8 connections simplify field wiring.

Applications

  • High-speed packaging and sorting machinery
  • Automotive assembly lines and robotic work cells
  • Decentralized material handling and conveyor installations
  • Wet and washdown environments requiring ingress protection

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EP1518-0002
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw type
Specification EN 61131-2, type 1/3
Number of Inputs 8 (2 usable as 32-bit up/down counters)
Input Connections M12 x 1, 5-pin, A-coded
Counting Frequency Max. 1 kHz
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Adjustable 0 to 100 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current Typ. 3 mA (EN 61131-2, type 3)
Distributed Clocks Yes
Sensor Supply From control voltage, max. 0.5 A per 4 sensors, short-circuit proof
Power Supply Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
Current Consumption from Us 120 mA
Electrical Isolation 500 V
Weight Approx. 165 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)

Connections and Interfaces

Interface Type Connection Standard Description
EtherCAT Bus 2 x M8 socket, shielded, screw type Incoming and outgoing EtherCAT lines for daisy-chain topology.
Digital Inputs 4 x M12 x 1, 5-pin, A-coded sockets Connects up to 8 sensors (2 inputs per socket).
Power Supply Feed 1 x M8 male socket, 4-pin Feeds system and sensor supply voltage (Us).
Power Supply Downstream 1 x M8 female socket, 4-pin Passes power through to the next EtherCAT Box module.

Installation Guidelines

To ensure trouble-free operation and maintain the rated IP67 protection, observe the following field installation guidelines:

  • Torque Requirements: All M8 and M12 connectors must be tightened to their specified torque values to ensure an airtight, moisture-proof seal. Unused sockets must be sealed with protective caps.
  • Grounding and Shielding: Ensure the EtherCAT Box is securely mounted to a grounded metallic surface or bracket. Use shielded Ethernet cables with proper termination at the M8 bus connectors.
  • Cable Routing: Avoid routing signal and sensor lines adjacent to high-power motor cables or variable frequency drive (VFD) wiring to prevent electromagnetic interference.
  • Power Distribution: Respect the maximum current carrying capacities of the M8 power connectors when daisy-chaining modules to avoid voltage drops across the segment.

Compliance and Certifications

  • CE
  • UL
  • ATEX

Can the EP1518-0002 handle high-speed signal processing?

Yes. The EP1518-0002 features eight digital inputs, two of which can be configured as 32-bit up/down counters with a maximum counting frequency of 1 kHz.

What is the environmental protection rating of this module?

When properly mated with all connectors and caps secured, the EP1518-0002 complies with IP65, IP66, and IP67 standards, allowing direct machine mounting in harsh industrial environments.

How is the sensor power managed on the EP1518-0002?

The sensor supply is derived from the control voltage (Us), providing a maximum current of 0.5 A per group of four sensors with built-in short-circuit protection.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...