Description

Engineered for direct field deployment without an electrical cabinet, the Beckhoff EP3174-0002 provides highly precise acquisition of analog industrial signals over EtherCAT. This rugged IP67-rated module features four individually parameterizable differential inputs, allowing seamless software configuration between voltage (-10 to +10 V) and current (0/4 to 20 mA) measurement modes per channel. By combining high-speed 16-bit analog-to-digital conversion with Distributed Clocks capability, it guarantees synchronized, low-latency data acquisition across decentralized network architectures.

Product Features

  • Four Parameterizable Channels: Individually configurable for -10/0...+10 V or 0/4...20 mA signals via TwinCAT software.
  • Rugged IP67 Protection: Fully sealed housing enables direct machine mounting under harsh environmental conditions.
  • High-Resolution Digitization: 16-bit analog-to-digital converter (including sign) delivers precise process values.
  • Distributed Clocks (DC): Supports microsecond-precise synchronization with other EtherCAT network components.
  • Diagnostic Feedback: Integrated status LEDs for EtherCAT network state, channel condition, and auxiliary power.

Applications

  • Automotive assembly lines and decentralized manufacturing cells.
  • Process automation installations requiring field-mounted sensors.
  • Multi-axis motion control synchronization using Distributed Clocks.
  • Wind power plants and heavy machinery tracking in high-vibration zones.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model Number EP3174-0002
Protocol EtherCAT
Number of Inputs 4 differential inputs
Signal Type -10 V to +10 V | 0 mA to 20 mA | 4 mA to 20 mA (configurable per channel)
Resolution 16-bit (including sign)
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Common-Mode Voltage (U_CM) Max. 35 V
Measurement Error < +-0.3% (relative to full scale value)
Conversion Time approx. 100 microseconds
Input Filter Limit Frequency 5 kHz (configurable filter)
Nominal Power Supply 24 V DC (-15% / +20%)
Current Consumption from U_S 120 mA
Electrical Isolation 500 V (functional isolation)
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Ex Marking II 3 G Ex nA IIC T4 Gc (ATEX Zone 2)
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Net Weight approx. 165 g
Shipping Weight (Calculated) 2.0 kg (including protective packaging)

Connections and Interfaces

Connection Port Connector Type Signal Assignment
EtherCAT Bus (In/Out) 2 x M8 socket, shielded, screw type EtherCAT transmit and receive pairs
Analog Inputs (Channels 1-4) 4 x M12 female connector, 5-pin, A-coded Differential Input +, Differential Input -, Sensor Supply (+24V UP), Ground (GND), Shield
Power Feed 1 x M8 male socket, 4-pin Control voltage U_S (24V DC), Load voltage U_P (24V DC)
Power Downstream 1 x M8 female socket, 4-pin Loop-through of U_S and U_P to downstream modules

Empirical Engineering Insights

Alternative Models & Compatibility

The EP3174-0002 serves as the IP67 field-mounted equivalent of the Beckhoff EL3174 EtherCAT Terminal. While they share identical TwinCAT process image structures and parameterization objects (CoE index 0x8000), note that physical fieldbus routing differs: the EP module requires M8 cabling rather than terminal blocks. Ensure TwinCAT 3 version 3.1.4024 or higher is deployed to take full advantage of the advanced diagnostic indices.

Application Pitfalls & Engineering Notes

The common-mode voltage limit (U_CM) is rated at a maximum of 35 V. If your differential signals are referenced to a ground potential that floats beyond this limit relative to the module's supply ground, measurement saturation or analog front-end damage can occur. Always verify that a low-impedance ground connection is maintained between decoupled power domains. When operating in current mode, the module presents an internal resistance of approximately 85 Ohms plus a diode voltage drop; ensure your field transmitters have sufficient compliance voltage to drive this combined load.

Commissioning & Wiring Tips

By default, channels may initialize in voltage mode. To parameterize a channel to current mode (e.g., 4 to 20 mA), navigate to the TwinCAT System Manager, select the EP3174-0002 module, go to the CoE - Online tab, and modify the "Presentation" and "Range" indices inside the 0x80n0 object directory (where n corresponds to the channel index 0 to 3). For maximum high-frequency noise immunity, construct a 360-degree shield termination on the M12 mating connector backshell to ground electromagnetic interference directly to the module's integrated mounting plate.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Ensure all power supplies (U_S and U_P) are physically isolated and locked out before initiating mounting, wiring, or maintenance on this EtherCAT Box. Failure to de-energize the fieldbus line can lead to sudden electrical arcs, damage to high-sensitivity internal conversion components, or unexpected machinery behavior.

1

Mount the module onto a flat, grounded metallic surface using two M3 screws through the mounting holes. Ensure the metal plate has a low-impedance connection to the machine chassis ground.

2

Connect the incoming EtherCAT network cable to the top-left M8 socket (marked as IN) and the downstream line to the OUT socket. Securely hand-tighten the M8 threaded collars to achieve IP67 protection.

3

Wire the analog field sensors to the respective M12 (Channels 1 to 4) sockets using shielded, twisted-pair cables. Use torque wrenches calibrated for M12 connectors (typically 0.6 Nm) to seal the interface.

4

Apply 24V DC auxiliary power to the M8 power feed socket. Verify that the "Us" (Logic Power) and "Up" (Peripheral Power) LED indicators glow solid green prior to starting the EtherCAT master network scan.

Loading product navigation…

How do I switch the EP3174-0002 channels between current and voltage mode?

Channel modes must be parameterized in TwinCAT using the CoE (CANopen-over-EtherCAT) online interface. Locate the module, access the 0x80n0 index (where 'n' is the zero-indexed channel number), and configure the range and signal type parameters accordingly.

What is the maximum common-mode voltage supported by this module?

The module supports a maximum common-mode voltage (U_CM) of 35 V. Exceeding this limit relative to the module ground will result in saturation of measurements or structural damage to the analog inputs.

Does this module require an enclosure or cabinet for field installation?

No. The EP3174-0002 features a fully encapsulated IP65/IP66/IP67 rated plastic housing, meaning it can be mounted directly onto machinery in wet, dusty, or high-vibration environments.

What software version is required to program and integrate this unit?

The module requires a TwinCAT runtime/system manager configuration setup. We recommend utilizing TwinCAT 3 (v3.1.4024 or higher) for full access to standard diagnostic parameters and precise Distributed Clock settings.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...