Description

Managing signal routing and power levels within decentralized topologies is simplified with this dedicated junction block. The Beckhoff EPP1332-0001 is a specialized EtherCAT P Box designed to branch EtherCAT P networks while simultaneously refreshing the critical system/sensor voltage (Us) and peripheral/actuator voltage (Up). By injecting fresh 24 V DC power, this module counteracts cumulative voltage drops across long daisy chains, ensuring stable operations for downstream nodes. Equipped with robust M8 P-coded connectors, it functions as a 2-port junction that splits a single incoming line into three separate downstream branches, making it ideal for distributed machinery installations.

Key Features

  • Dual Junction & Refresh: Provides network branching while feeding fresh auxiliary power to both Us and Up lines.
  • P-Coded M8 Interfaces: Heavy-duty, screw-type, P-coded connections prevent accidental cross-connection with standard EtherCAT signals.
  • Compact Multi-Branch Topology: Accepts 1 x EtherCAT P input and delivers 3 x EtherCAT P outputs.
  • IP65/66/67 Protection: Fully sealed enclosure protects internal components against water ingress, dust, and heavy industrial washes.
  • Status Diagnostics: Dedicated LED indicators provide instant physical verification of active communications and voltage status.

Industrial Applications

  • Modular Machine Construction: Distributing control and power across independent machinery sections without needing multiple electrical cabinets.
  • Automotive Assembly Lines: Wiring dense arrays of proximity sensors and pneumatic manifolds over long physical distances.
  • Material Handling & Logistics: Conveyor belt networks where modular distribution boxes require localized power replenishment.
  • Robotic End-of-Arm Tooling: Lightweight, decentralized routing of power and control signals on moving mechanical arms.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number EPP1332-0001
Protocol EtherCAT P
Bus Interface M8 socket, shielded, screw-type, P-coded
Number of Channels IN: 1 x EtherCAT P, OUT: 3 x EtherCAT P
Nominal Supply Voltage 24 V DC (-15% / +20%)
Current Consumption from Us Typically 100 mA
Max. Power Pass-Through Current 3 A maximum per Us and Up for all EtherCAT P ports total
Power Feed Connection Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin
Data Transfer Rate 100 Mbit/s (100BASE-TX)
Distributed Clocks No
Max. Station Distance 100 m
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Physical Weight Approx. 165 g
Shipping Weight (Calculated) 0.55 kg (including packaging material)
Dimensions (Calculated) 120 mm x 30 mm x 26.5 mm
Standards & Approvals CE, UL

Connections and Interfaces

Connector / Interface Pin Allocation / Type Functional Assignment
EtherCAT P IN M8 female, 4-pin, P-coded Incoming EtherCAT P network and power line
EtherCAT P OUT (x3) M8 female, 4-pin, P-coded Downstream EtherCAT P branched networks
Power Feed IN M8 male, 4-pin External 24 V DC supply input to refresh Us and Up
Power Feed OUT M8 female, 4-pin Loop-through of auxiliary supply to next junction box

Empirical Engineering Insights

Alternative Models & Compatibility

The EPP1332-0001 is designed strictly for EtherCAT P (integration of data and power on one cable) and cannot be integrated into standard, non-P EtherCAT (EP series) chains without standard-to-P conversion modules (such as EP9128). Attempting to force-fit standard M8 Ethernet cables will fail due to the proprietary, protective keyway layout of the P-coded M8 socket.

Application Pitfalls & Engineering Notes

While the device is physically rated for up to 3 A per Us and Up power paths, continuous execution at or near 3 A inside enclosed, high-ambient spaces will generate thermal stress. Implement dynamic power budget calculations within TwinCAT System Manager to predict line voltage drops. Always account for cable resistance (especially with long ZS2020 series cables) before designating your next refresh node.

Commissioning & Wiring Tips

When running high-noise actuator lines, ensure the ground tab of the EPP1332-0001 housing is directly connected to a low-impedance copper ground bus. For proper ingress prevention, use a calibrated torque wrench on the M8 connections (typically 0.4 Nm). Unused ports must be fitted with certified protective caps to maintain the IP67 rating.

Installation Guidelines

CRITICAL WARNING:

Before mounting or terminating any connectors, ensure all main and auxiliary 24 V DC power sources (Us and Up) are completely de-energized. Do not hot-plug P-coded M8 interfaces; doing so risks contact arcing and can damage sensitive downstream PHY transceiver chips.

1

Securely bolt the EPP1332-0001 to your machine chassis or mounting bracket using the integrated mounting holes. Ensure the surface is flat to prevent mechanical twisting of the housing.

2

Connect the incoming EtherCAT P cable to the EtherCAT P IN M8 port. Tighten the collar to 0.4 Nm.

3

Connect the 24 V DC external refresh power supply to the Power Feed IN socket using standard 4-pin M8 cabling.

4

Attach downstream branch networks to the three OUT ports. Seal any unused ports with protective caps.

5

Energize the system and confirm the status of active power and link synchronization via the module's onboard diagnostics LEDs.

Loading product navigation…

What is the primary function of the EPP1332-0001 junction box?

The EPP1332-0001 acts as a 2-port EtherCAT P junction that splits a single network branch into three directions, while simultaneously allowing the injection of fresh 24 V DC to replenish the Us (system/sensor) and Up (actuator) power rails.

Can I use standard RJ45 or non-P M8 EtherCAT cabling with this device?

No. This module features physical P-coding on its M8 connection ports, which prevents connection with standard EtherCAT M8 cables. You must use dedicated EtherCAT P cables to maintain system integrity.

Is software configuration inside TwinCAT required for this module?

No software configuration is required for the basic network branching and power refresh capabilities of the module, though you can monitor diagnostics in TwinCAT.

What is the maximum current capacity supported by the power refresh lines?

The module supports a maximum of 3 A total current for all EtherCAT P ports combined, applicable to both the Us and Up paths individually.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...