1 daripada 1

BECKHOFF ERI2338-0001 IO-Link Box

BECKHOFF ERI2338-0001 IO-Link Box

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: ERI2338-0001

  • Negara asal:Jerman

  • Jenis Produk: IO-Link Modules

  • Pembayaran: T/T, Western Union

  • Berat: 265g

  • Dimensi: 30 mm x 126 mm x 26.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed for decentralized signal routing in demanding environments, the BECKHOFF ERI2338-0001 IO-Link box provides a highly adaptable interface for digital field devices. This robust module features eight digital channels that can be individually parameterized as inputs or outputs, allowing versatile configuration tailored to sensor or actuator requirements. Operating on the IO-Link V1.1 Class B specification, the unit transmits data at high-speed COM 3 rates of 230.4 kbaud.

Housed in a rugged, zinc die-cast enclosure, the module achieves ingress protection ratings of IP65, IP66, and IP67, enabling direct machine-mount installation without control cabinets. Complete electrical isolation between the logic supply (L+) and the actuator load power (P24) ensures system-wide signal integrity and fault isolation in high-noise industrial networks.

Features

  • Configurable 8-channel digital interface operating as inputs or outputs.
  • Robust zinc die-cast housing designed for high-stress industrial applications.
  • Supports IO-Link V1.1 Class B with a COM 3 transmission rate of 230.4 kbaud.
  • M8 screw-type connectors for reliable field device attachment.
  • Individually short-circuit proof outputs rated at 0.5 A per channel.
  • Adjustable input filtering range from 0 to 20 ms.
  • Complete galvanic isolation between L+ control power and P24 load voltage.

Applications

  • Decentralized assembly lines and robotics.
  • Automotive manufacturing and body shop applications.
  • Material handling systems and packaging machinery.
  • Field-level sensor/actuator integration in harsh physical environments.

Technical Specifications

ManufacturerPart Number / ModelCommunication ProtocolData Transfer RateNumber of ChannelsInput Filter TimeInput Voltage TypeInput CurrentSensor Supply VoltageLoad TypesRated Load VoltageMax. Output CurrentShort-Circuit CurrentCurrent Consumption (L+)Auxiliary Power CurrentElectrical IsolationHousing MaterialWeightDimensions (W x H x D)Operating TemperatureStorage TemperatureProtection RatingVibration / Shock ResistanceEMC Immunity / Emission
BECKHOFF
ERI2338-0001
IO-Link V1.1, Class B
230.4 kbaud (COM 3)
8 digital inputs or outputs (individually configurable)
3.0 ms (default), adjustable from 0 to 20 ms
"0" signal: -3 to +5 V, "1" signal: 11 to 30 V (EN 61131-2, type 3)
Typ. 3 mA (EN 61131-2, type 3)
From P24, max. 0.5 A total, short-circuit proof
Ohmic, inductive, lamp load
24 V DC (-15% / +20%)
0.5 A per channel from P24, individually short-circuit proof
Max. 1.5 A
Typ. 100 mA from L+
Typ. 20 mA + load
Yes (between L+ and P24)
Zinc die-cast
Approx. 265 g
30 mm x 126 mm x 26.5 mm
-25 to +60 degC
-40 to +85 degC
IP65, IP66, IP67 (conforms to EN 60529)
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Interface Type Connector Configuration Function
IO-Link Interface 1 x M12 plug, A-coded System integration and master-level communication
I/O Connections 8 x M8, screw type Digital sensor/actuator channel wiring

Installation Guidelines

  • Mount the unit directly onto a flat, rigid machine frame or profile using the two 3.5 mm diameter fixing holes designed for M3 screws.
  • Ensure all M8 and M12 mating cable connections are screwed tight to ensure the IP65/66/67 ingress protection remains fully intact.
  • Seal all unused M8 and M12 ports with certified protective caps to prevent dust and water entry.
  • Ensure proper system grounding paths in compliance with EN 61000-6-2 guidelines to guarantee optimal electromagnetic compatibility.

Compliance and Certifications

  • CE
  • UL

What is the primary communication standard of the Beckhoff ERI2338-0001?

The ERI2338-0001 complies with the IO-Link V1.1 Class B specification and supports communication speeds up to 230.4 kbaud (COM 3).

Are the channels on the ERI2338-0001 fixed or configurable?

The module contains 8 digital channels that can be individually configured as either inputs or outputs based on operational demands.

What protection rating does this IO-Link box offer?

It is constructed with a rugged zinc die-cast housing and is rated IP65, IP66, and IP67, making it suitable for direct mounting in harsh wet or dusty machine environments.

Is there electrical isolation in the ERI2338-0001?

Yes, there is full galvanic electrical isolation between the L+ logic supply and the P24 load voltage path.

What type of physical connectors are used for digital I/O?

The digital inputs and outputs use standard M8 screw-type connectors, while the IO-Link interface uses a 1 x M12 A-coded plug.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...