Distributed control architectures requiring resilient, high-speed fiber-optic communications utilize the IP1001-B200 Lightbus fieldbus box to bridge field-level signals with centralized controllers. Designed by Beckhoff, this rugged I/O module integrates directly into the Lightbus ring topology, providing reliable data rates up to 2.5 Mbaud. Its optical fiber physical layer ensures complete immunity to electromagnetic interference (EMI), making it an excellent choice for environments with high electrical noise, such as welding cells or heavy machinery installations.

The IP1001-B200 is housed in a fully sealed enclosure, allowing direct machine mounting without an additional control cabinet. It features a dual-circuit power system that isolates the sensitive control electronics from the field load voltage. System configuration is executed seamlessly via the Beckhoff KS2000 software tool or directly through the master controller, simplifying deployment and diagnostic routines.

Features

  • High-speed Beckhoff Lightbus interface with 2.5 Mbaud transmission speed.
  • Dual fiber-optic connections utilizing ZS1020-0010 plug systems for optimal signal integrity.
  • Robust IP65/66/67 rating for reliable operation in dust, moisture, and washdown environments.
  • Isolated power supply distribution with dedicated M8 connectors for control voltage feed and downstream forwarding.
  • Flexible, orientation-independent physical installation.

Applications

  • Automotive manufacturing lines and robotic welding systems.
  • Packaging, food processing, and bottling plants requiring washdown protection.
  • Material handling systems and overhead cranes.
  • Heavy industrial machinery requiring distributed, EMI-immune control networks.

Technical Specifications

ManufacturerModel / Part NumberBus InterfaceData Transfer RateControl Voltage Power SupplyLoad Voltage Power SupplyPower Feed ConnectionDownstream Power ConnectionElectrical IsolationWeightOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection ClassInstallation PositionApprovals
Beckhoff Automation
IP1001-B200
2 x fiber-optic socket for plug ZS1020-0010
2.5 Mbaud
24 V DC (-15% / +20%)
Determined by connected I/O configuration
1 x M8 male connector, 4-pin
1 x M8 female connector, 4-pin
Yes (control voltage to fieldbus)
approx. 250 g
0 to +55 degC
-25 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65/66/67 (conforms to EN 60529)
Variable (any mounting orientation)
CE, UL

Connections and Interfaces

M8 Male (4-pin)M8 Female (4-pin)Fiber-Optic RxFiber-Optic Tx
Connection Type Interface Description
Feed: 24 V DC control voltage input
Downstream: 24 V DC power distribution loop
Lightbus optical receiver channel
Lightbus optical transmitter channel

Installation Guidelines

When installing the module, ensure the fiber-optic cables are routed to strictly maintain their minimum specified bend radius to prevent signal attenuation or physical damage. Mount the box securely to a flat surface using the integrated mounting holes. For installations requiring IP67 protection, all unused M8 and fiber-optic ports must be sealed using the appropriate protective caps, and mating connectors must be fully torqued according to manufacturer guidelines.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the primary communication protocol of the IP1001-B200?

The IP1001-B200 communicates using the Beckhoff Lightbus protocol, utilizing optical fibers for high noise immunity at transmission rates up to 2.5 Mbaud.

What power supply connections does this fieldbus box use?

It is equipped with a 4-pin M8 male connector for the main 24 V DC control voltage feed and a 4-pin M8 female connector for looping power downstream.

Is a protective enclosure required for this module?

No, because it features an IP65/66/67 environmental protection rating, the IP1001-B200 can be mounted directly on the machinery or in the field without an enclosure.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...