1 daripada 1

Beckhoff IP1002-B810 Fieldbus Box 8-channel Digital Input Module

Beckhoff IP1002-B810 Fieldbus Box 8-channel Digital Input Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP1002-B810

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 30 mm x 175 mm x 26.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Decentralized signal acquisition on machine frames and production lines is executed reliably by the Beckhoff IP1002-B810 Fieldbus Box. This device gathers binary control signals from up to eight digital sensors and transmits them over a point-to-point RS232 interface to the master controller. Housed in a robust, fully-sealed polyamide shell, the IP1002-B810 does not require a protective sub-cabinet, enabling direct machine-mount installation in heavy industrial settings. Key features include an integrated 3.0 ms input filter to prevent contact bounce and standard M12 screw-type connection points for rugged sensor field-wiring.

Features

  • 8 Digital Inputs: Supports direct connection of standard 24 V DC binary sensors.
  • RS232 Serial Interface: Peer-to-peer communication protocol with selectable data transfer rates up to 38.4 kbaud.
  • Rugged Sealed Housing: Highly durable PA6 polyamide design conforms to IP65, IP66, and IP67 protection classes.
  • Input Filtering: Integrated 3.0 ms hardware filter to suppress signal noise and contact chatter.
  • Flexible Mounting: Two pre-drilled 3.5 mm structural fixing holes for direct M3 screw attachment to machinery.

Applications

  • Distributed packaging machine automation systems.
  • Conveyor and material handling control networks.
  • Wet process areas requiring high ingress protection ratings.
  • Dedicated serial peer-to-peer data logging configurations.

Technical Specifications Table

Parameter Specification
Manufacturer Beckhoff Automation
Model Reference IP1002-B810
Product Type Fieldbus Box Digital Input Module
Number of Inputs 8 digital inputs
Interface Protocol RS232 (open, documented protocol)
Data Transfer Rates 9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default)
Nominal Input Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 2)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 2)
Input Filter Time 3.0 ms
Box Current Consumption 45 mA + sensor current (max 0.5 A total)
Power Supply Connections Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Bus Interface Connection 1 x M12 socket, 5-pin, B-coded
Sensor Connections M12, screw-type connection
Housing Material PA6 (Polyamide)
Ingress Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Approvals CE, UL
Dimensions (W x H x D) 30 mm x 175 mm x 26.5 mm
Net Weight Approx. 210 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector/Terminal Function / Pin Assignment
M8 Power Feed (Male) Pin 1: +24 V DC Control Voltage (US), Pin 2: +24 V DC Load Voltage (UP), Pin 3: GND (US), Pin 4: GND (UP)
M8 Downstream (Female) Daisy-chain connection to downstream modules (US, UP, GND US, GND UP)
M12 Bus Interface (B-coded) RS232 Serial communication lines (RXD, TXD, GND interface connections)

Empirical Engineering Insights

Alternative Models & Compatibility

The IP1002-B810 model relies on a standard RS232 peer-to-peer connection, which is distinct from the fieldbus-specific IP1002 network modules (such as CANopen or PROFIBUS variants). When configuring the serial link, ensure the controller's serial port parameters match the module's default baud rate of 38.4 kbaud. Standard configuration tasks can be managed directly using Beckhoff's KS2000 software interface via the specified programming adapters.

Application Pitfalls & Engineering Notes

Because RS232 is an unbalanced communication interface, the maximum length of the serial connection cable is strictly limited to 15 meters. Exceeding this distance or using low-grade unshielded cables in high-interference environments (e.g., adjacent to variable frequency drives) will lead to transmission errors and module timeouts. Ensure that the total current draw of connected sensors does not exceed the short-circuit protected limit of 0.5 A across the module.

Commissioning & Wiring Tips

When routing the control cables, use shielded copper wiring (2 x 0.25 mm²) specifically rated for RS232 transmissions. Ensure the shield is grounded properly on the host controller side. For the M8 power distribution daisy chain, verify that the cumulative control voltage (US) draw of all downstream modules does not exceed the contact rating of the feed connectors, which is typically capped at 4 A.

Installation Guidelines

CRITICAL WARNING: Prior to mounting or performing any wiring work on the Fieldbus Box, ensure all power sources—both control voltage (US) and auxiliary load voltage (UP)—are fully de-energized. Failure to isolate power can result in terminal damage, sensor damage, or unexpected system state transitions.
1
Mechanical Mounting: Secure the IP1002-B810 to a flat machine surface using two M3 screws through the 3.5 mm diameter mounting holes. Tighten to the recommended torque spec for your mounting substrate.
2
RS232 Bus Connection: Insert the B-coded 5-pin M12 bus cable into the communication port. Hand-tighten the screw coupling to secure the IP67-rated seal.
3
Power Feed Integration: Connect the incoming 24 V DC power source to the 4-pin M8 male connector. If daisy-chaining, run an M8 cable from the female downstream port to the next fieldbus module.
4
I/O Sensor Termination: Connect the 8 digital sensors to the respective M12 peripheral connections. Seal all unused ports with M12 protective caps to prevent fluid ingress and maintain the IP67 rating.
Loading product navigation…

What is the primary communication protocol used by the IP1002-B810?

This module utilizes a point-to-point RS232 serial interface with selectable baud rates of 9.6 kbaud, 19.2 kbaud, and 38.4 kbaud (default).

What is the maximum allowed cable distance for the RS232 connection?

The maximum recommended transmission cable length for the RS232 connection is 15 meters using high-quality shielded copper cable.

How do you configure the configuration parameters of this Fieldbus Box?

Configuration parameters and communication settings for the module can be adjusted through the Beckhoff KS2000 software environment.

Does the module require a separate protective electrical enclosure?

No, the IP1002-B810 features an IP65/66/67-rated polyamide housing that is fully sealed against moisture, dust, and direct liquid washdowns.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...