1 daripada 1

Beckhoff IP2001-B518 Fieldbus Box 8-Channel Digital Output Module

Beckhoff IP2001-B518 Fieldbus Box 8-Channel Digital Output Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: IP2001-B518

  • Negara asal:Jerman

  • Jenis Produk: Fieldbus I/O Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 30 mm x 210 mm x 26.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered for decentralized automation architectures, the Beckhoff IP2001-B518 establishes direct, field-level digital actuation via the CANopen protocol. This high-density, IP67-rated Fieldbus Box permits the direct connection of up to eight digital actuators to a high-speed CAN network, negating the need for protective electrical enclosures. Each of the eight outputs delivers up to 0.5 A at 24 V DC, making it suitable for driving solenoid valves, contactors, indicators, and small DC motors under demanding ambient environments.

Features

  • 8 Digital Outputs: Standard 24 V DC switching logic with individual short-circuit protection.
  • Direct CANopen Integration: Built-in node management supporting life/node guarding, emergency objects, and variable PDO mapping.
  • Integrated T-Connector: Dual M12 fieldbus interfaces simplify daisy-chaining without external junction blocks.
  • Submersible Enclosure: Encapsulated PA6 polyamide housing rated for IP65, IP66, and IP67 protection zones.
  • Compact M8 Actuator Ports: Space-optimized termination for industrial sensors and actuator cables.

Applications

  • Machine-mount control systems omitting local terminal boxes.
  • Material handling systems and modular conveyor networks.
  • Pneumatic valve manifold control in food processing and packaging machinery.
  • Mobile equipment and material transport systems utilizing CANopen system buses.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation GmbH & Co. KG
Model Number IP2001-B518
Fieldbus Protocol CANopen (up to 16 send/receive PDOs)
Baud Rate Detection Automatic: 10 kbaud to 1 Mbaud
Number of Outputs 8 digital outputs
Output Voltage 24 V DC (-15% / +20%)
Maximum Output Current 0.5 A per channel (individually short-circuit proof)
Short-Circuit Current Limit Typical 1.5 A
Bus Interface Connectors 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) integrated T-connector
Power Supply Connection Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Internal Current Consumption 45 mA from Us + sensor load (max 0.5 A)
Isolation Voltage 500 V (Control voltage to fieldbus logic)
Ingress Protection Rating IP65 / IP66 / IP67 (conforming to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Housing Material PA6 Polyamide
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Connector Type Pin Allocation Signal Assignment
M12 CANopen Bus (Plug/Socket) Pin 1 CAN Shield / PE
Pin 2 V+ (CAN Bus Power Supply)
Pin 3 V- (CAN Bus Reference Ground)
Pin 4 CAN_H (Signal High)
Pin 5 CAN_L (Signal Low)
M8 Power Feed (4-Pin Male) Pin 1 +24 V DC Control Voltage (Us)
Pin 2 +24 V DC Load Voltage (Up)
Pin 3 GND Control (GNDs)
Pin 4 GND Load (GNDp)

Alternative Models & Compatibility

The IP2001-B518 is fully compatible with the Beckhoff KS2000 configuration software for parameterization and monitoring. When replacing legacy IP2001-B510 modules, verify standard network address switch settings and register maps, as the B518's integrated T-connector structure limits the need for external network splitting hardware.

Application Pitfalls & Engineering Notes

While the module features a total load-handling capacity of up to 4 A across all 8 channels, total heat dissipation within highly confined non-ventilated spaces must be modeled carefully. Additionally, when switching highly inductive loads, such as large pneumatic solenoid coils, external suppressor circuits or free-wheeling diodes should be placed at the load to protect the internal short-circuit monitoring circuitry from inductive kickback transients.

Commissioning & Wiring Tips

Always ensure that the CANopen network is terminated with 120-Ohm resistors at both physical endpoints of the trunk line. Use high-quality, shielded copper twisted-pair cabling for connection to the integrated M12 T-connector interface to avoid data frame corruption in environments with heavy variable frequency drive (VFD) interference.

Installation Guidelines

CRITICAL WARNING:

De-energize all primary system power loops (Us and Up) before inserting, removing, or wiring the Fieldbus Box. Failure to remove supply lines can trigger catastrophic bus controller faults or damage the short-circuit protection profiles of the outputs.

1

Mount the housing to a rigid surface using the two integrated 3.5 mm diameter fixing holes designed for M3 screws.

2

Route the CANopen bus topology through the integrated M12 T-connector, confirming secure hand-tightening of mating connectors to preserve the IP67 seal rating.

3

Connect the 4-pin M8 power feed cable. Ensure separation of control logic voltage (Us) and output load voltage (Up) lines if diagnostic separation is required.

Loading product navigation…

Can the outputs of the IP2001-B518 be connected in parallel to increase drive current?

No, connecting output channels in parallel to drive larger loads is not supported. The internal short-circuit and overload protection algorithms monitor individual channel profiles and will trip due to unequal load balancing.

What is the purpose of the integrated T-connector on the CANopen interface?

The integrated M12 T-connector allows fieldbus cabling to daisy-chain directly into and out of the module without requiring external multi-port junctions, maintaining physical topology continuity even if a drop cable is disconnected.

Does this module require a separate configuration file for deployment?

Yes, network integration inside a CANopen master configuration tool requires the matching EDS (Electronic Data Sheet) file provided by Beckhoff for the IP2001-B518 series.

How does the short-circuit protection operate on the outputs?

Each output is individually protected. If a short-circuit occurs, the output current is limited to approximately 1.5 A. The module logs the diagnostic event and safely disables the faulted channel while other outputs remain operational.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...