BECKHOFF KL1889 Bus Terminal Series HD Bus Terminal

BECKHOFF KL1889 Bus Terminal Series HD Bus Terminal

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: KL1889

  • Negara asal:Jerman

  • Jenis Produk: HD Bus Terminals

  • Pembayaran: T/T, Western Union

  • Berat: 55g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered for high-density space conservation in control cabinets, the BECKHOFF KL1889 is a High-Density (HD) Bus Terminal featuring sixteen digital inputs in a compact 12 mm housing width. Operating with negative switching (sink) logic, this module incorporates 1-wire connection technology, allowing direct connection of sensors and signals to the process image without excessive terminal blocks. Designed for seamless integration into K-bus networks, the KL1889 enables efficient signal acquisition in restricted spaces while simplifying wiring and minimizing hardware requirements.

Features

  • Provides 16 digital inputs within a compact 12 mm mechanical footprint.
  • Utilizes negative switching (sink) logic configuration.
  • Employs 1-wire connection technology with direct plug-in connection for solid conductors.
  • Tool-free termination for solid conductors; simple spring actuation by screwdriver for stranded wires and ferrules.
  • Integrated hardware input filter (typ. 3.0 ms) to suppress line bounce and noise.
  • Complete 500 V galvanic isolation between the internal K-bus and the field potential.
  • Address-free configuration for immediate plug-and-play installation within the Bus Coupler process image.

Applications

  • Space-constrained decentralized control systems and distribution cabinets.
  • Automated assembly systems, packaging machinery, and material handling lines.
  • Sensor signal concentration in industrial process automation.
  • General manufacturing and PLC I/O expansion environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model KL1889
Connection Technology 1-wire
Specification Negative switching (sink)
Number of Inputs 16
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage 18 to 30 V
"1" Signal Voltage 0 to 7 V
Input Filter typ. 3.0 ms
Input Current typ. 3 mA
Current Consumption (K-bus) typ. 20 mA
Current Consumption (Power Contacts) typ. 4 mA + load
Electrical Isolation 500 V (K-bus to field potential)
Bit Width in Process Image 16 inputs
Conductor Connection (Solid) Direct plug-in technique (0.08 to 1.5 mm²)
Conductor Connection (Stranded) Spring actuation by screwdriver (0.25 to 1.5 mm²)
Conductor Connection (Ferrule) Spring actuation by screwdriver (0.14 to 0.75 mm²)
Weight approx. 55 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Class IP20

Connections and Interfaces

Connection Type Conductor Type Cross-section Range
Direct Plug-In Solid Wire 0.08 to 1.5 mm²
Screwdriver Spring Actuation Stranded Wire 0.25 to 1.5 mm²
Screwdriver Spring Actuation Ferrule 0.14 to 0.75 mm²

Installation Guidelines

  • Ensure the system power supply is completely disconnected before mounting or removing the terminal.
  • Mount the module onto a standard 35 mm DIN rail (EN 60715) with vertical or horizontal mounting orientation as required.
  • Ensure the side locking mechanism of the bus terminal engages correctly with adjacent terminals to secure reliable K-bus and power contact transmission.
  • Utilize appropriate shielding and grounding procedures for sensor lines to prevent electromagnetic interference from distorting input signals.

Compliance and Certifications

  • CE
  • UL
  • Ex
  • GL
Loading product navigation…

What is the signal logic used by the BECKHOFF KL1889?

The KL1889 uses negative switching (sink) logic with 16 digital inputs.

What type of connection technology does the KL1889 support?

The module utilizes 1-wire connection technology, allowing direct conductor routing for digital signals with minimal wiring overhead.

Does the KL1889 require software addressing during setup?

No, the KL1889 is address-free and does not require software configuration; it integrates automatically into the K-bus process image.

What are the allowed conductor types and sizes for connection?

It supports solid wire (0.08 to 1.5 mm²), stranded wire (0.25 to 1.5 mm²), and ferrules (0.14 to 0.75 mm²).

What is the IP rating of the KL1889 housing?

The KL1889 has an IP20 protection class and must be installed within an appropriate control cabinet or enclosure.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...