1 daripada 1

BECKHOFF KS3444 Bus Terminal 4-Channel Analog Input Module

BECKHOFF KS3444 Bus Terminal 4-Channel Analog Input Module

Hanya 10 item tinggal dalam stok
  • Pengilang: BECKHOFF

  • No. Produk: KS3444

  • Negara asal:Jerman

  • Jenis Produk: Bus Terminals

  • Pembayaran: T/T, Western Union

  • Berat: 55g

  • Dimensi: 12 mm x 100 mm x 68 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Industrial processing systems utilize the BECKHOFF KS3444 analog input bus terminal to interface standard 0 to 20 mA signals directly from the field level to the higher-level automation controller. This four-channel module features single-ended inputs and provides a highly space-efficient design with a pluggable wiring level, enabling fast, tool-free installation and maintenance. By operating directly through the standard K-bus, the unit transmits digitized process values back to the coupler or controller with a 12-bit resolution. Integrated electrical isolation of 500 V between the K-bus and the signal channels guarantees high noise immunity and signal integrity in demanding electrical environments.

Features

  • Four single-ended analog inputs handling standard 0 to 20 mA current loops.
  • Pluggable connection level (KS-series design) allowing pre-wiring and rapid terminal replacement.
  • Compact 12 mm housing width to optimize control cabinet and DIN rail space.
  • K-bus powered with a typical current consumption of 85 mA.
  • Reliable performance across a broad operating temperature range of 0 to +55 degC.
  • Sturdy design complying with EN 60068-2-6 and EN 60068-2-27 for vibration and shock resistance.

Applications

  • Chemical and petrochemical processing plants.
  • Water and wastewater treatment facilities.
  • Machinery manufacturing and factory automation.
  • HVAC and building automation controls.

Technical Specifications

CategoryTechnical ParameterValue
Manufacturer BECKHOFF KS3444
Product Type Bus Terminal (Pluggable wiring level) 4
Signal Current 0 to 20 mA Single-ended
Internal Resistance < 85 Ohm 12 bit
Conversion Time approx. 2 ms < ±0.3 % (relative to full scale value)
Surge Voltage Resistance 30 V DC 500 V (K-bus/signal voltage)
Current Consumption K-Bus typ. 85 mA Input: 4 x 16 bit data (4 x 8 bit control/status optional)
Housing Material Polycarbonate IP20 / variable
Operating Temperature 0 to +55 degC -25 to +85 degC
Relative Humidity 95 %, non-condensing Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4 35 mm DIN rail (EN 60715) with lock
Connection Cross-section Solid/Stranded: 0.08 to 1.5 mm²; Fine-wire: 0.14 to 1.5 mm² AWG 28 to 16 (Solid/Stranded); AWG 26 to 16 (Fine-wire)
Stripping Length 9 to 10 mm 12 mm x 100 mm x 68 mm
Weight 0.055 kg II 3 G Ex nA IIC T4 Gc

Connections and Interfaces

Connection Point Signal Assignment
Terminal 1 Input 1 (+)
Terminal 2 Input 2 (+)
Terminal 3 Input 3 (+)
Terminal 4 Input 4 (+)
Terminal 5 Input 1 (0 V)
Terminal 6 Input 2 (0 V)
Terminal 7 Input 3 (0 V)
Terminal 8 Input 4 (0 V)

Installation Guidelines

  • Mount the terminal on a standard 35 mm DIN rail conforming to EN 60715. Ensure the locking mechanism is securely engaged.
  • To wire the pluggable KS terminal, use a flat-bladed screwdriver to actuate the integrated tension clamp mechanism.
  • Ensure the system power supply is deactivated before plugging or unplugging the terminal wiring block to prevent damage to the K-bus connections.
  • Observe regional grounding and shielding guidelines for analog signal cables to minimize electromagnetic interference.

Compliance and Certifications

  • CE
  • UL
  • ATEX (II 3 G Ex nA IIC T4 Gc)
  • DNVGL
Loading product navigation…

What is the primary difference between the Beckhoff KL3444 and the KS3444?

The KS3444 features a pluggable wiring level, allowing the terminal block connector to be detached from the main housing without disconnecting individual field wires. The KL3444 has a fixed wiring level.

Does the KS3444 require an external power supply for K-bus communication?

No, the KS3444 is powered directly via the K-bus backplane from the bus coupler or controller, drawing a typical current of 85 mA.

Is the Beckhoff KS3444 suitable for hazardous locations?

Yes, the KS3444 is ATEX certified with Ex marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas when installed in an appropriate enclosure.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...