1 daripada 3

Bently Nevada 330750-20 High Temperature Velomitor System

Bently Nevada 330750-20 High Temperature Velomitor System

Hanya 2 item tinggal dalam stok
  • Pengilang: Bently Nevada

  • No. Produk: 330750-20

  • Negara asal:Amerika Syarikat

  • Jenis Produk: High Temperature Velomitor System

  • Kod bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 635g

  • Dimensi: 8.8cm x 3.6cm x 7.1cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Option 20 (2 meters integrated hardline cable length) specifies this High Temperature Velomitor System configuration — 330750-20. This industrial piezoelectric velocity sensor segregates the sensing element from the signal conditioning electronics, enabling reliable machinery casing vibration monitoring in extreme thermal environments. With this design, the sensing head can be mounted on surfaces reaching temperatures up to 400 degC (752 degF).

By using a permanently connected integrated hardline cable, the 330750-20 eliminates intermediate connectors, which are a major source of signal loss and mechanical transducer failures in hot zones. The 2-meter cable allows the signal conditioning electronics to be positioned in a cooler location with operating temperatures from -55 degC to 121 degC (-67 degF to 250 degF) to preserve long-term reliability. This system captures high-quality casing velocity measurements comparable to standard velocity sensors but at significantly higher operating temperatures.

Features

  • Option 20 Cable Length: Includes a 2-meter integrated hardline cable connecting the sensing head directly to the conditioning electronics.
  • Extreme Temperature Support: Sensing head and hardline cable withstand operating surface temperatures up to 400 degC (752 degF).
  • Segregated Transducer Design: Places delicate signal conditioning electronics in a separate housing to run in a cooler zone.
  • Connectorless Sensor Interface: Permanent hardline cable attachment prevents connector fatigue and failure in extreme heat.
  • Nominal Velocity Output: Standard 5.7 mV/mm/s (145 mV/in/s) sensitivity for direct integration with Bently Nevada machinery protection monitors.
  • Hermetically Sealed Head: 300-series stainless steel case protects against moisture and severe industrial environments.

Applications

  • Gas and steam turbine casing vibration monitoring
  • High-temperature exhaust duct and piping analysis
  • Exhaust gas expander casing measurements
  • Boiler feed pumps and extreme-temperature rotating machinery protection

Ordering Information

Option / Segment Code on This SKU Description
Orderable Part Number 330750-20 High Temperature Velomitor System, standard mounting
A - Cable Length 20 2.0 meters (6.6 feet) of integrated hardline cable

Technical Specifications

Manufacturer Bently Nevada
Part Number / Model 330750-20
Product Type High Temperature Velomitor System
Sensitivity 5.7 mV/mm/s (145 mV/in/s) plus or minus 5% at 100 Hz
Frequency Response 15 to 2000 Hz plus or minus 3.0 dB; 20 to 1000 Hz plus or minus 0.9 dB
Sensing Head Temperature Range -55 degC to 400 degC (-67 degF to 752 degF)
Hardline Cable Temperature Range -55 degC to 400 degC (-67 degF to 752 degF)
Electronics Temperature Range -55 degC to 121 degC (-67 degF to 250 degF)
Transverse Sensitivity Less than 5% of sensitivity
Amplitude Linearity plus or minus 2% up to 152 mm/s (6 in/s) peak
Mounted Resonant Frequency Greater than 5 kHz
Output Bias Voltage -12 plus or minus 2.0 VDC nominal
Broadband Noise Floor 0.127 mm/s (0.005 in/s) rms nominal (15 Hz to 2 kHz)
Grounding Case isolated
Maximum Interconnect Cable Length 305 meters (1000 feet) with no signal degradation
Case Material 300 series stainless steel
Connector Type 2-pin Mil-C-5015 receptacle, hermetically-sealed, 304 stainless steel shell
Minimum Cable Bend Radius 51 mm (2.0 in)
Shock Survivability 24,535 m/s2 (2500 g) peak
Relative Humidity Limits To 100% non-submerged (hermetically sealed)
Weight 635 grams (1.40 lb) typical

Connections and Interfaces

Pin Designation Function / Description
Pin A Positive Signal (Velocity Output)
Pin B Signal Common / Return

Installation Guidelines

  • Cable Bend Radius: Maintain a minimum bend radius of 51 mm (2.0 in) for the integrated hardline cable to prevent internal conductor damage.
  • Environmental Protection: Position the signal conditioning electronics inside a weatherproof enclosure with wiring protected in conduit for outdoor installations.
  • Mounting Surface: Secure the sensing head to a flat, smooth, clean surface with correct torque to facilitate high-frequency vibration transfer.
  • Thermal Considerations: Verify that the signal conditioning electronics housing does not exceed its maximum operating limit of 121 degC.

Compliance and Certifications

  • ATEX Directive 2014/34/EU
  • EMC Directive 2014/30/EU
  • RoHS Directive 2011/65/EU
  • Hazardous Area Approvals (with safe barrier): Class I, Division 1, Groups A, B, C, D (T4/T1); Class I, Zone 0, Ex ia IIC T4/T1 Ga; Class I, Division 2, Groups A, B, C, D; Class I, Zone 2, Ex ec IIC T4/T1 Gc
Loading product navigation…
Key Features:

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330750-20 High Temperature Velomitor System

What does the '-20' suffix specify for the Bently Nevada 330750-20 system?

The '-20' option code specifies that this High Temperature Velomitor System is configured with a 2-meter (approx. 6.6 feet) integrated hardline cable connecting the sensing head and electronics.

What is the maximum operating temperature for the sensing head of this system?

The sensing head and the integrated hardline cable can withstand maximum operating surface temperatures of up to 400 degC (752 degF).

Why does this sensor system use a segregated design with an integrated cable?

It isolates the signal conditioning electronics from extreme machine surface temperatures, enabling the electronics to be installed in a cooler area (-55 degC to 121 degC) while eliminating intermediate connectors that often fail.

What is the nominal output sensitivity of the 330750-20?

The system provides a nominal sensitivity of 5.7 mV/mm/s (145 mV/in/s) plus or minus 5% at 100 Hz.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...