The Bently Nevada 136719-01 (part of the 3500/04-01 assembly) is an Earthing I/O Module designed for intrinsically safe (IS) ground reference management within the 3500 Machinery Protection System. Installed directly into the rear of the 3500 system rack, the 136719-01 provides the essential intrinsically safe earth connection through the 3500 system backplane to interface with internal barrier monitor I/O modules. This configuration enables safe, direct interconnection with approved field transducers—such as 3300 XL Proximitor sensors, Velomitor sensors, thermocouples, and RTDs—operating in hazardous environments without requiring external barriers or compromising system performance.

Features

  • Provides the intrinsically safe ground connection for internal barrier I/O modules via the 3500 system backplane.
  • Installs in a dedicated monitor position within the standard 3500 Machinery Protection System rack.
  • Fully integrated backplane routing eliminates the need for external zener or galvanic isolation barrier units.
  • Supports combined rack layouts hosting both internal barrier modules and standard I/O modules.

Applications

  • Intrinsically safe field wiring grounding for 3500 Machinery Protection Systems in hazardous industrial areas.
  • Turbomachinery vibration, speed, position, and temperature monitoring systems requiring IS loop protection.

Ordering Information

Part Number / Option Code Description
3500/04-AA-BB 3500/04 Internal Barrier System
A: I/O Module Type 01 Earthing I/O Module
B: Agency Approval

00 None

01 North American Hazloc

02 Multi (CSA, ATEX, IECEx)

136719-01 Earthing I/O Module (Spare Part)
138257-01 Earthing Module Front Panel (Spare Part)

Technical Specifications

Specification Category Parameter / Value
Manufacturer Bently Nevada
Module Type Earthing I/O Module (3500/04 IS Earthing Module)
Dimensions (H x W x D) 241 mm x 24.4 mm x 103.1 mm (9.50 in. x 0.96 in. x 4.06 in.)
Weight 0.201 kg (0.443 lb.)

Installation Guidelines

  • Rack Slot Allocation: The 136719-01 IS Earthing Module requires a dedicated monitor position in the rack, which limits a standard 19-inch rack to 13 monitor positions.
  • Positioning: Locate the IS Earthing Module in a rack position that allows easy access for routine online maintenance. When positioned between internal barrier I/O modules, allow a minimum of two rack positions to facilitate online access.
  • Requirement: Any 3500 rack containing internal barrier I/O modules must be equipped with a 3500/04-01 IS Earthing Module to provide the backplane IS earth path.
  • Wiring Separation: Route hazardous area field wiring above the 3500 rack and safe area wiring below to maintain a minimum physical separation of 50 mm (2 in).

Compliance and Certifications

Standard / Approval Type Certificate / Standard Level
FCC Complies with Part 15 of FCC Rules
EMC Directive European Community Directive 2014/30/EU; EN 61000-6-2, EN 61000-6-4
Electrical Safety European Community Directive 2014/35/EU; EN 61010-1
Marine Classification DNV GL rules for classification; ABS Rules Part 1
cNRTLus Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, D; T4 @ Ta = -20 degC to +65 degC
ATEX / IECEx II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 3500/04-01 136719-01 Earthing I/O Module

Which chassis slot does the earthing module occupy in the rack?

The module installs into a dedicated monitor position on the 3500 rack backplane, reducing available monitor slots to 13.

Does the earthing module require software configuration?

The module acts as a passive backplane ground reference interface and does not require independent software programming.

Can standard and internal barrier modules coexist in the same chassis?

Standard and internal barrier modules can reside in the same chassis provided the earthing module establishes backplane IS ground.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Perak
Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

What Is a PLC? The Controllers That Still Run the Plant Floor

PLCs still run the plant floor: scan cycles, I/O, and IEC 61131-3 languages decide whether machines stay deterministic. Here is how controllers work, where they win, and where they strain.

What It Really Takes to Learn Industrial Automation in 2026

Learning industrial automation now means mastering PLCs, networks, and protection systems—not just robots. This guide maps skills, pitfalls, and career paths for engineers entering control-heavy...

Memodenkan HMI Bailey INFI 90 Symphony yang Beroperasi pada OpenVMS Alpha

Panduan praktikal untuk menggantikan stesen pengendali Bailey Symphony yang sudah berusia dan berjalan pada OpenVMS Alpha. Panduan ini membandingkan emulasi Alpha, migrasi OpenVMS x86, pemindahan...

Mengapa Data Penyelenggaraan Penting untuk Kebolehpercayaan Industri

Data penyelenggaraan menghubungkan perintah kerja, isyarat penderia, sejarah aset, kos dan pengetahuan juruteknik. Jika digunakan dengan baik, data ini meningkatkan perancangan, kebolehpercayaan,...

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Bendalir: Panduan Praktikal Automasi Industri

Artikel ini menerangkan cara penggerak elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Artikel ini...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan cara sistem PLC melaksanakan operasi matematik asas seperti penambahan, penolakan, pendaraban, pembahagian, modulo dan pengkuasaan dalam automasi industri. Artikel ini...