1 daripada 1

Bently Nevada 3500/15-04-04-00 3500 Series Power Supply Module

Bently Nevada 3500/15-04-04-00 3500 Series Power Supply Module

Hanya 5 item tinggal dalam stok
  • Pengilang: Bently Nevada

  • No. Produk: 3500/15-04-04-00

  • Negara asal:Amerika Syarikat

  • Jenis Produk: PLC Power Supplies

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered to deliver clean, highly stable electrical power to the 3500 machinery protection system rack, the Bently Nevada 3500/15-04-04-00 functions as a high-reliability, low-voltage power supply module. This module accepts low-voltage DC inputs to convert incoming primary power into the regulated voltages required by the monitoring and communications modules housed within the rack. It supports a dual-redundant power configuration to maximize system availability in heavy industrial process plants, petroleum refineries, and power generation facilities where continuous asset monitoring is crucial.

Features

  • Redundant Power Support: Accommodates primary and secondary low-voltage DC feeds to ensure uninterrupted system operations during a single power source failure.
  • Integrated Diagnostics: Front-panel status LEDs indicate 'Power Supply OK' and 'Over-Temperature' conditions for immediate field troubleshooting.
  • Transient Isolation: Built-in internal filters isolate sensitive rack components from electromagnetic interference (EMI) and external line transients.
  • Robust Safety Architecture: Features automatic overcurrent and overvoltage shutdown mechanisms to safeguard installed monitoring modules.

Applications

  • Turbine, generator, and compressor vibration monitoring networks.
  • Oil and gas petrochemical plant machinery protection racks.
  • Critical balance-of-plant rotating machinery assets.
  • Power generation steam and gas turbine systems.

Technical Specifications Table

Parameter Specification Value
Manufacturer Bently Nevada
Model Series 3500 Machinery Protection System
Part Number 3500/15-04-04-00
Primary Supply Option Low Voltage DC (20 to 30 Vdc)
Backup Supply Option Low Voltage DC (20 to 30 Vdc)
Input Voltage Range 20 to 30 Vdc
Agency Approvals None (00 Option)
Country of Origin U.S.A.
Net Weight 1.39 kg
Shipping Weight (Calculated) 2.50 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The 3500/15-04-04-00 model represents an all-low-voltage DC configuration. When replacing older 3500/15 units, ensure that your rack's backplane power terminal input block is designed specifically for 24 Vdc nominal feeds. Installing a DC module into a rack pre-wired for high-voltage AC (such as 3500/15-01-xx options) will damage the internal terminal pins. If migrating from legacy configurations, check physical card guide clearances on early-revision 3500 chassis.

Application Pitfalls & Engineering Notes

Under full rack loads (all 14 monitor slots populated with dual-channel relays or high-draw seismic cards), thermal dissipation within the power supply modules increases. Maintain a clear ventilation path above and below the 3500 enclosure. Avoid combining a low-voltage DC supply and a high-voltage AC supply within the same chassis unless the rack backplane has been explicitly verified for mixed-voltage dual-source layouts, as failure to switch over during a fault can occur with unmatched impedance feeds.

Commissioning & Wiring Tips

Always utilize shielded, twisted pair cables (minimum 12 AWG) for the DC input terminals to protect the backplane from common-mode noise. Ensure the frame ground terminal on the input block is tied back to your instrument clean ground with a low-impedance connection. This prevents ground loops from corrupting the transient monitoring data signals passing through the neighboring monitor cards.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and secondary external DC power feeds before attempting to slide the power supply module into the rack slot. Failing to completely isolate incoming power lines can cause hazardous electric arcing, leading to physical degradation of the backplane contacts and unexpected rack reboots.
1

Isolate and verify that the low-voltage DC supply lines measure below 2 Vdc before connecting any conductors to the rear terminal blocks.

2

Slide the module along the chassis card guides in the designated slot (usually the extreme left of the 3500 rack) until the connectors bottom out firmly.

3

Secure the module's integrated faceplate screws to the frame chassis to ensure robust grounding and vibration-proof mounting.

4

Energize the DC source supply and verify the front faceplate green 'OK' LED is stably illuminated.

Loading product navigation…

What is the input voltage range for this module?

The module operates within a nominal input voltage range of 20 to 30 Vdc for both its primary and backup channels.

Can I mix this low-voltage DC module with an AC module for redundant operation?

No. In redundant systems, both power supply modules installed in the same rack must use identical voltage input types to function correctly.

What does the '04-04-00' suffix indicate?

It specifies that both the primary and backup supply options are configured for low-voltage DC inputs, with no agency approvals selected.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...