1 daripada 1

Bently Nevada 3500/32-01-00 3500 Series 4-Channel Relay Module

Bently Nevada 3500/32-01-00 3500 Series 4-Channel Relay Module

Hanya 3 item tinggal dalam stok
  • Pengilang: Bently Nevada

  • No. Produk: 3500/32-01-00 (125712-01 + 125720-01)

  • Negara asal:Amerika Syarikat

  • Jenis Produk: 4-Channel Relay Modules

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Dimensi: 29.2 cm x 15.4 cm x 10.2 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Providing programmable alarm relay outputs within the machinery protection framework, the Bently Nevada 3500/32-01-00 functions as a highly reliable 4-channel relay interface for the 3500 Machinery Protection System. This configuration comprises the 149986-02 spare control module and the 125720-02 spare relay output module. Each channel can be independently programmed with logic equations to trigger shutdowns or alert sequences based on status inputs from adjacent monitoring modules in the rack. The system relies on its integrated backplane connectivity to bypass external communication latencies, executing safety-critical operations with deterministic accuracy.

Key Features

  • Four fully independent, software-programmable Single Pole Double Throw (SPDT) relay outputs.
  • Modular design dividing logic processing (control module) and physical connection interfaces (I/O module).
  • Highly configurable voting logic (AND, OR, and notary combinations) defined via the 3500 Rack Configuration Software.
  • Onboard LED indicators on the front panel display real-time OK and individual relay actuation statuses.
  • Supports normally energized (de-energize-to-trip) or normally de-energized (energize-to-trip) wiring configurations.

Industrial Applications

  • Turbine emergency trip and overspeed shutdown systems.
  • Reciprocating and centrifugal compressor safety interlocks.
  • Large industrial fan and blower auxiliary control loops.
  • Generator and motor winding temperature alarm management.

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada
Model Number 3500/32-01-00
Component Cards 149986-02 (Control Module) + 125720-02 (I/O Module)
Number of Channels 4 SPDT Relays
Relay Contact Rating (Resistive) 5 A @ 240 VAC (50/60 Hz) / 5 A @ 30 VDC
Power Consumption 5.8 Watts (typical)
Agency Approvals Option -00 (None)
Relay Life Expectancy 100,000 cycles at rated load
Operating Temperature -30 degC to +65 degC
Country of Origin USA
Shipping Weight (Calculated) 2.20 kg
Package Dimensions (Calculated) 29.2 cm x 15.4 cm x 10.2 cm

Wiring Connection and Terminal Assignments

Terminal Designation Relay Channel Function Assignment
Ch 1 - NC / COM / NO Relay 1 Normally Closed / Common / Normally Open Contacts
Ch 2 - NC / COM / NO Relay 2 Normally Closed / Common / Normally Open Contacts
Ch 3 - NC / COM / NO Relay 3 Normally Closed / Common / Normally Open Contacts
Ch 4 - NC / COM / NO Relay 4 Normally Closed / Common / Normally Open Contacts

Empirical Engineering Insights

Alternative Models & Compatibility

The 149986-02 is the modernized, direct functional replacement for older legacy control card revisions such as the 125712-01. When swapping individual components rather than the entire 3500/32 assembly, confirm that the firmware version programmed in the 149986-02 is compatible with the existing rack backplane and the version of your 3500 System Configuration Software.

Application Pitfalls & Engineering Notes

When switching inductive loads (such as heavy-duty interlock solenoids or intermediate auxiliary contactors), contact arc discharge can lead to contact welding or EMI generation that disrupts adjacent monitoring channels. Systems engineers must install external RC snubbers or flyback diodes across the inductive load to protect the relay contacts from high-voltage transient spikes.

Commissioning & Wiring Tips

Ensure to carefully audit the state of the relays during rack boot-up sequence. Configured as "Normally Energized," these relays will transition states momentarily when power is applied to the rack. Critical shutdown lines must be interlocked or temporarily bypassed during power cycling to prevent spurious machinery trips.

Installation Guidelines

CRITICAL WARNING

Do not hot-swap the 125720-02 I/O module if high voltage is present on any field terminals. Fully isolate and de-energize all connected relay lines before removing the I/O module from the rear of the rack to avoid hazardous arcing or catastrophic personnel injury.

1
Power down the 3500 rack and disconnect all field power connections linked to the 125720-02 terminal blocks.
2
Slide the 149986-02 control card into the designated slot from the front of the rack until the ejector levers snap shut.
3
Align and slide the 125720-02 I/O module into the corresponding slot on the rear of the rack, tightening both securing screws securely.
4
Connect to the system using the 3500 Rack Configuration Software to assign channels and upload the logic validation profile.
Loading product navigation…

Can the 3500/32-01-00 module be used in any slot in the 3500 rack?

No. The 3500/32 4-Channel Relay Module can be installed in any slot except for slots 1 and 2, which are strictly reserved for the Rack Interface Module (RIM) and the Power Supply.

What is the key difference between the 149986-02 and the older 125712-01 control cards?

The 149986-02 is a newer, fully functional replacement card. It features updated hardware components to improve thermal efficiency and long-term reliability while maintaining complete functional compatibility with legacy backplanes.

Does this specific -01-00 option configuration support functional safety or hazardous area zones?

The -00 agency approval code indicates no specific explosion-proof or hazardous area certifications are applied to this configuration. For systems requiring functional safety or ATEX/IECEx compliance, look for hazardous area-rated suffixes.

How do you switch highly inductive loads with this module safely?

To prevent relay contacts from welding due to voltage spikes when inductive loads are switched off, you must install external RC suppression networks for AC circuits or flyback diodes for DC circuits across the load.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Aktuator Elektrik Direka untuk Menggantikan Cecair: Tutorial Praktikal

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...