1 daripada 1

Delta Electronics VFD1100C43A-00 VFD-C2000 Series Variable Frequency Drive

Delta Electronics VFD1100C43A-00 VFD-C2000 Series Variable Frequency Drive

Hanya 10 item tinggal dalam stok
  • Pengilang: Delta Electronics

  • No. Produk: VFD1100C43A-00

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 2500g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

High-power industrial motor control applications require precise torque and speed management, which is delivered efficiently by the Delta Electronics VFD1100C43A-00 adjustable frequency AC drive. Engineered as part of the high-performance VFD-C2000 series, this three-phase variable frequency drive offers advanced field-oriented control (FOC) for optimal versatility across induction and permanent magnet synchronous motors. Operating within the 460V class, this robust power modulator supports heavy-duty operations while maintaining exceptional energy efficiency and dynamic response.

The Delta Electronics VFD1100C43A-00 is configured within a Frame E physical layout and features an IP00/Open Type enclosure design. This setup makes the drive ideal for integration inside specialized industrial control panels, safeguarding it against challenging environmental conditions while facilitating streamlined thermal management. Built-in PLC functionality and integrated communication protocols allow seamless automation integration with DCS, PLC, and SCADA architectures.

Features

  • Advanced Field Oriented Control (FOC) and sensorless vector algorithms for highly accurate motor shaft control.
  • Built-in PLC functionality for localized execution of custom control logic and sequence programs.
  • Heavy-duty and normal-duty dual rating options to match specific torque characteristics.
  • Modbus communication integrated as standard to simplify network configuration.
  • Chassis-optimized Frame E design with IP00 protection rating for neat panel installation.

Applications

  • Municipal and industrial water treatment pumping stations.
  • Heavy material handling, conveying systems, and mechanical lifters.
  • Large-scale HVAC fans, industrial blowers, and air handling systems.
  • Extruders, mixers, and processing equipment in chemical or plastic manufacturing.

Technical Specifications

Manufacturer Delta Electronics
Model / Part Number VFD1100C43A-00
Series VFD-C2000
Product Type Variable Frequency Drive (VFD)
Applicable Motor Capacity (kW) 110 kW
Applicable Motor Capacity (HP) 150 HP
Rated Output Current 220 A
Input Voltage Rating 460 V AC (3-Phase)
Input Frequency Range 50 / 60 Hz
Enclosure Protection Rating IP00 / Open Type
Frame Size Frame E
Mounting Configuration Wall Mount (Internal Panel Cabinet Mount)
Control Methods FOC, Sensorless Vector, V/f Control, PM Sensorless Control

Connections and Interfaces

Terminal Name Functional Assignment
R/L1, S/L2, T/L3 3-Phase AC Line Input Connections
U/T1, V/T2, W/T3 3-Phase AC Output Connections to Motor
+1, +2 DC Reactor Connection Terminals
PE Protective Earth / Ground Terminal

Installation Guidelines

  • Panel Enclosure: Because this unit features an IP00 protection rating, it must be mounted inside a closed, protective control cabinet (minimum IP20/NEMA 1 or higher) to avoid accidental contact and limit particulate exposure.
  • Thermal Considerations: Install vertically on a flat, non-combustible surface. Maintain recommended physical clearance around the Frame E chassis to ensure unobstructed cooling airflow.
  • Grounding & Shielding: Connect the dedicated PE grounding terminal directly to the main system earth. Utilize shielded motor cables to mitigate high-frequency electromagnetic interference (EMI).

Compliance and Certifications

  • CE Compliant
  • UL / cUL Listed
  • RoHS Directive Compliant
Loading product navigation…

What is the power and current output of the Delta VFD1100C43A-00?

The Delta VFD1100C43A-00 has an applicable motor capacity of 110 kW (150 HP) with a rated continuous output current of 220 Amperes.

What does the IP00 protection rating indicate?

IP00 indicates that the unit is an open-frame type drive with no specific ingress protection. It is designed to be installed inside an appropriate, protected industrial control cabinet.

What motor types are compatible with this VFD-C2000 series drive?

The drive supports both standard induction motors and permanent magnet (PM) synchronous motors using high-precision field-oriented control (FOC) algorithms.

Does the VFD1100C43A-00 include integrated communication options?

Yes, standard Modbus communication protocol is built-in. Additional protocols can be utilized by installing optional network cards.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...