1 daripada 1

Honeywell FC-SDOL-0424 Safety Manager Digital Output Module

Honeywell FC-SDOL-0424 Safety Manager Digital Output Module

Hanya 6 item tinggal dalam stok
  • Pengilang: Honeywell

  • No. Produk: FC-SDOL-0424

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Safety Digital Output Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

To manage safety-critical field actuators within Honeywell Safety Manager environments, the FC-SDOL-0424 serves as a ruggedized fail-safe digital output module. This industrial component features four monitored output channels designed to drive 24 Vdc loads such as solenoid valves, indicators, and interposing relays up to 1 A per channel. Built-in short-circuit protection and overload detection mechanisms ensure high system availability and safety integrity in demanding industrial process control topologies. Each channel is monitored for line monitoring capabilities, allowing the safety controller to track field-side wiring integrity in real time.

Features

  • Four independent, short-circuit proof solid-state source output channels operating at 24 Vdc.
  • High-integrity diagnostic functions including overload detection and off-state leakage monitoring.
  • Internal fail-safe architecture designed for high-availability Safety Instrumented Systems (SIS).
  • Compact physical footprint conforming to standard Eurocard dimensions (4 HP width, 3U height).
  • Integrated watchdog (WDG) input verification to align output states with controller commands.

Applications

  • Emergency Shutdown Systems (ESD) in petrochemical plants.
  • Fire and Gas (F&G) mitigation control and alarming networks.
  • Burner Management Systems (BMS) in industrial boilers and power generation facilities.
  • Critical process safety interlocks in water treatment and chemical refineries.

Technical Specifications

Manufacturer Honeywell
Part Number/Model FC-SDOL-0424
Module Type Digital Output Module (Fail-safe)
Number of Channels 4
Output Configuration 24 Vdc solid-state source (short-circuit proof)
Maximum Channel Current 1 A
Maximum Total Module Load 3.6 A (dissipation limit)
Maximum Load Inductance 0.5 H
Maximum Load Capacitance 1 uF
Overload Detection Threshold Greater than 10 Ohm
Cold Lamp Resistance Greater than 20 Ohm
Voltage Drop Less than 1.3 V at 1 A
Off-state Leakage Current Less than 0.1 mA
Current Sense Voltage Drop Less than 1 V at 1 A
Watchdog (WDG) Input Current 4 mA
Power Requirements (5 Vdc) 15 mA
Power Requirements (24 Vdc Internal) 50 mA
Power Requirements (24 Vdc External) 15 mA (without output load)
Space Requirements 4 TE, 3 HE (4 HP, 3U rack space)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Insert the module into an allocated slot within a compatible 3U Safety Manager rack, ensuring secure locking and alignment with backplane connectors.
  • Wiring: Field connection paths must use correctly rated wire gauges to handle continuous 1 A loads. Route low-voltage diagnostic lines separated from high-current AC power cables.
  • Cooling: Maintain clearance margins at the top and bottom of the subrack assembly to allow convective airflow, keeping operating temperatures within specifications.

Compliance and Certifications

  • CE
  • TUV (for safety instrumented functions up to SIL 3)
  • UL Listed
  • CSA Certified
  • FM Approved (Class I, Division 2 Hazardous Locations)
Loading product navigation…

What is the maximum output current capacity per channel for the FC-SDOL-0424?

Each of the 4 channels supports a maximum continuous current of 1 A, with a maximum module-wide load limit of 3.6 A due to thermal dissipation parameters.

Does the FC-SDOL-0424 digital output module support short-circuit protection?

Yes, the module is equipped with solid-state source outputs that are fully short-circuit proof and include overload detection thresholds.

Which safety systems is the FC-SDOL-0424 compatible with?

The module is designed for Honeywell Safety Manager systems and is certified by TUV for use in safety instrumented systems (SIS) up to SIL 3.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...