1 daripada 3

Honeywell MC-TAMT04 (51305890-175) Experion PKS LLMUX2 Thermocouple Field Termination Assembly

Honeywell MC-TAMT04 (51305890-175) Experion PKS LLMUX2 Thermocouple Field Termination Assembly

Hanya 5 item tinggal dalam stok
  • Pengilang: Honeywell

  • No. Produk: MC-TAMT04 51305890-175

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Thermocouple Field Termination Assembly

  • Kod Bar: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 850g

  • Dimensi: 360 mm x 180 mm x 100 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

The Honeywell MC-TAMT04 (Part Number 51305890-175) is a high-reliability, 16-channel LLMUX2 Thermocouple Field Termination Assembly (FTA) engineered for integration with Honeywell Experion PKS, xPM, and Experion PMIO architectures. Utilizing advanced solid-state technology, this module replaces legacy mercury-wetted relays, eliminating environmental hazards while drastically improving loop resistance tolerances to allow longer field thermocouple wiring runs. The assembly is equipped with an integrated local Cold Junction Reference (CJR), high-performance compression terminals, a single Input/Output Processor (IOP) interface, and a robust conformal coating for continuous duty in harsh, corrosive industrial environments.

Features

  • Per-Channel Isolation: 16 fully-isolated channels providing robust channel-to-channel, channel-to-PM, and channel-to-power supply common separation.
  • Solid-State Relay Architecture: Replaces traditional mercury-wetted components to provide enhanced stability and long-term operating life.
  • Dedicated A/D Per Channel: High-performance analog-to-digital conversion circuits per channel ensure precise signal tracking.
  • Fast Open-Thermocouple Detection: Built-in advanced diagnostics identify open-circuit faults within a fixed 1-second interval.
  • Dual-Purpose Design: The same underlying 51305890-175 hardware handles both local and remote cold junction tracking through an on-board jumper configuration.
  • Corrosive Environment Protection: Factory conformally coated to meet stringent industrial atmospheric standards and maintain CE compliance.

Applications

  • Experion PKS distributed control systems (DCS) process monitoring.
  • High-density temperature acquisition loops in hydrocarbon processing and petrochemical facilities.
  • Thermal monitoring and profiling inside gas turbines, boilers, and heavy industrial furnaces.
  • Corrosive chemical processing plants requiring conformally coated process interface equipment.

Technical Specifications Table

Parameter Specification
Manufacturer Honeywell
Model Number MC-TAMT04
Base FTA Part Number 51305890-175
Input Channels 16 channels (fully-isolated)
Input Scan Rate 1 Second fixed by IOLP
Channel Bandwidth 0 to 4.7 Hz (-3 dB)
Nominal Input Range -20 to +100 millivolts
Maximum Input (Non-Damaging) -10 to +10 volts continuous
Gain Error 0.050% full scale maximum (-20 to +100 millivolt range)
Resolution of Reading 2 microvolt per bit
Temperature Stability +/-20 ppm per degC maximum
Long Term Drift 500 ppm
Input Impedance 1 megohm at dc
Common Mode Voltage (CMV) +/-250 Vdc or Vac rms (channel-to-channel and channel-to-PM common)
CMRR (50 or 60 Hz) 120 dB minimum (with 1000 ohms source impedance maximum)
NMRR (50 or 60 Hz) 60 dB minimum
Supported Thermocouple Types Type J (-200 to +1200 Celsius), Type K (-100 to +1370 Celsius), Type E (-200 to +1000 Celsius), Type T (-230 to +400 Celsius), Type B (+100 to +1820 Celsius), Type S (0 to +1700 Celsius), Type R (0 to +1700 Celsius), Japan Type R' (0 to +1770 Celsius)
Cold Junction Compensation Range -20 to +60 degC
CJR Compensation Accuracy +/-0.5 degC typical
Surge Protection IEEE SWC 472-1974 certified at sensor terminals
Power Dissipation 2.25 watts maximum
Thermal Dissipation 7.68 Btu per hour maximum
Supply Voltage Range 15 to 30 Vdc (24 Vdc nominal)
Supply Current 160 milliamps at 15 Vdc
Operating Environmental Limits 0 to 50 degC; 10 to 90% non-condensing relative humidity (derated to max 40 degC)
Storage Environmental Limits -40 to 80 degC
Agency Certifications CSA Certified Class 1, Division 2, Groups A, B, C, D; UL listed; CE Compliant
Dimensions (H x W x D) 307.34 mm L x 124.46 mm W x 63.5 mm D (12.1 x 4.9 x 2.5 inches)
Country of Origin United States
Shipping Weight (Calculated) 1.25 kg (2.75 lbs)
Package Dimensions (Calculated) 360 mm x 180 mm x 100 mm

Alternative Models & Compatibility

The MC-TAMT04 serves as a direct form, fit, and functional replacement for legacy, obsolete LLMUX TC FTA variants. It seamlessly replaces non-CE compliant boards MU-TAMT02 (51401491-100) and MC-TAMT02 (51401491-150), alongside older CE-compliant models MU-TAMT03 (51309223-125) and MC-TAMT03 (51309223-175). Notably, the base board assembly (51305890-175) is identical to the one used in the remote cold junction reference model, MC-TAMT14.

Application Pitfalls & Engineering Notes

When evaluating field thermocouple loop resistances, the solid-state architecture of the LLMUX2 provides an expanded loop driving capability compared to old mercury systems, enabling longer field cable boundaries without signaling loss. However, engineers must carefully manage enclosure thermal metrics. The assembly dissipates up to 2.25 watts continuously, yielding a heat load of 7.68 Btu per hour. Ensure proper panel venting if multiple assemblies are grouped in dense Marshalling racks to avoid crossing the maximum 40 degC operational limit under high-humidity environments.

Commissioning & Wiring Tips

The unit utilizes a 6-pin compression plug for connection at the J6 port located at the top of the board assembly. If upgrading an older non-CE legacy cabinet setup that features a 4-pin plug, the internal wires must be extracted and reworked into the 6-pin connector provided in the MC-TAMT04 shipping container. Additionally, ensure the address jumper designated as "UNIT" is set correctly to '0' or '1' to mirror the address scheme of the existing system before connecting the 50-pin J1 cable interface to the Power Adapter.

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTRICAL SHOCK. Up to 250 Volts AC RMS or Vdc common mode voltage may be present underneath the primary protective plastic cover arising from external field process instrumentation loops. Disconnect all process control loop power and ensure proper lock-out/tag-out safety boundaries are fully enforced before removing the board cover or loosening field terminal connections.
1

Record the PV measurements of all active process loops from the central operations console to ensure validation benchmarks are available post-installation.

2

Unplug the primary 50-pin ribbon connector (J1) at the Power Adapter to fully decouple the LLMUX IOP from the local link system.

3

Loosen the retention screws on 8-pin terminal plug headers J1, J2, J3, and J4 to slide them away from the assembly without disconnecting field wiring leads.

4

Verify that the JMP2 jumper is set to the 'LOC' position on the replacement card to correctly engage the on-board Local Cold Junction Reference sensor circuit.

5

Mount the board into the standard enclosure tracking channel, secure the 4 corner retention standoffs, re-engage terminal headers, and reinstall the plastic safety cover.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell MC-TAMT04 (51305890-175) Experion PKS LLMUX2 Thermocouple Field Termination Assembly

Loading PDF, please wait…

How is the MC-TAMT04 module configured for local versus remote cold junction compensation?

The base Field Termination Assembly utilizes a dedicated onboard hardware jumper designated as JMP2. Setting this jumper to the LOC position activates the local cold junction reference sensor circuit populated directly on the board. Setting it to REM configures the assembly to receive compensation data from an external remote assembly.

What modifications are needed when replacing an older non-CE LLMUX card with this assembly?

Legacy non-CE assemblies often used a 4-pin plug at the J6 termination header. The newer module utilizes a 6-pin compression terminal design. Installers must extract the four wires from the legacy terminal plug and wire them into the new 6-pin compression block included with the module container.

Does the assembly support absolute ground referencing across all 16 channels?

No. The assembly features comprehensive galvanic separation up to +/-250 Vdc or Vac rms. Every input channel is isolated from adjacent channels, the power supply commons, and the primary Process Manager controller common bus to prevent field ground loops.

What is the fixed scan interval for thermocouple data acquisition through this unit?

The analog-to-digital conversion sampling sequence and input diagnostic processing loop run on a fixed scan timing interval of exactly 1 second, managed natively by the coupled Input/Output Link Processor.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Kelabu Hijau
Country of origin
Amerika Syarikat
Power source
Kuasa DC

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...