1 daripada 1

Mitsubishi Electric FR-A740-3.7K-CHT FR-A700 Series Inverter

Mitsubishi Electric FR-A740-3.7K-CHT FR-A700 Series Inverter

Hanya 10 item tinggal dalam stok
  • Pengilang: Mitsubishi Electric

  • No. Produk: FR-A740-3.7K-CHT

  • Negara asal:Amerika Syarikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 4000g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Engineered for high-demand industrial applications, the FR-A740-3.7K-CHT is a high-performance variable frequency drive (VFD) from the esteemed FR-A700 Series by Mitsubishi Electric. Designed to operate on a 3-phase 400V class power supply, this drive provides precise speed and torque control for motors up to 3.7 kW. It utilizes advanced vector control algorithms to achieve excellent dynamic response and accuracy, making it suitable for both simple speed control and highly complex torque-matching applications.

This unit is widely utilized as a core speed control component in heavy industries and manufacturing lines. For facilities undergoing modernization or system upgrades, please note that the FR-A740-3.7K-CHT legacy model has been succeeded by the FR-A840-00126-2-60 drive, though it remains highly sought after as an exact-fit replacement spare part to prevent costly system re-engineering.

Features

  • Real Sensorless Vector Control: Achieves high starting torque of 200% at ultra-low speeds (0.3 Hz) without requiring an encoder.
  • Adaptive Tuning: Automatically measures and adapts to motor parameters to optimize performance across varying motor brands.
  • Built-in PLC Functionality: Allows users to program custom operational sequences and internal logic directly within the drive.
  • Long-Life Component Design: Equipped with cooling fans and capacitors designed for an estimated service life of up to 10 years under standard operating conditions.
  • Integrated EMC Filter: Reduces electromagnetic interference to simplify compliance with noise regulations.

Applications

  • Material handling systems, conveyors, and overhead gantry cranes.
  • Centrifugal pumps, industrial fans, and localized ventilation blowers.
  • Extruders, mixers, and high-torque processing machinery.
  • Machine tool spindles and automated positioning systems.

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FR-A740-3.7K-CHT
Product Series FR-A700 Series
Input Voltage Class Three-phase 380 to 480 V AC (50Hz / 60Hz)
Applicable Motor Capacity 3.7 kW
Output Voltage Three-phase 380 to 480 V AC (Cannot exceed input voltage)
Control Method V/F Control, Advanced Magnetic Flux Vector Control, Real Sensorless Vector Control, Vector Control (with optional feedback card)
Cooling Method Forced Air Cooling
Enclosure Protection Rating IP20
Estimated Shipping Weight 4.0 kg

Connections and Interfaces

Terminal Symbol Terminal Name Description
R/L1, S/L2, T/L3 AC Power Input Connects to the three-phase AC mains power supply.
U, V, W Inverter Output Connects to the three-phase AC induction motor.
P/+, N/- DC Link Terminals Connection point for optional brake units or shared DC bus configurations.
PR, PX Brake Resistor Terminals Used for connecting an external discharge resistor for dynamic braking.
Earth / Ground Protective Earth (PE) Must be connected to a secure local ground to prevent electrical noise and ensure safety.

Installation Guidelines

  • Mounting Orientation: Install the drive vertically on a flat, non-flammable surface (such as a metal panel) to ensure proper natural convection and cooling.
  • Clearance Requirements: Maintain a minimum clearance of 50 mm on both left/right sides and 100 mm above/below the unit for unrestricted airflow.
  • Wiring Isolation: Separate power supply lines (R/L1, S/L2, T/L3) and motor output lines (U, V, W) from control signal cables to avoid electromagnetic cross-talk.
  • Grounding: Always ground the inverter and the motor securely. Ensure the ground resistance is 10 Ohms or less for 400V class equipment.
  • Ambient Temperature: Ensure the installation enclosure operates within an ambient temperature range of -10 degC to 50 degC (non-freezing).
Loading product navigation…

What is the rated input voltage and capacity of the FR-A740-3.7K-CHT?

The FR-A740-3.7K-CHT operates on a three-phase 380 to 480 V AC input at 50/60 Hz, and is designed for motors with a capacity of up to 3.7 kW.

Which current-generation model replaces the legacy FR-A740-3.7K-CHT?

Mitsubishi Electric lists the FR-A840-00126-2-60 as the modern functional replacement for the FR-A740-3.7K-CHT inverter.

Can this drive run in closed-loop vector control?

Yes, while it supports Real Sensorless Vector Control out of the box, it can perform full closed-loop vector control when fitted with an optional encoder feedback plug-in card.

What is the enclosure protection rating for this model?

This inverter features an IP20 open-type rating, suitable for installation inside a clean, protective electrical control panel.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Syarikat

Produk yang Baru Dilihat

Pengetahuan teknikal

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke gerabak lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...