1 daripada 1

Omron CPM1A-10CDT-A-V1 CPM1A Micro PLC CPU Module

Omron CPM1A-10CDT-A-V1 CPM1A Micro PLC CPU Module

Hanya 3 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: CPM1A-10CDT-A-V1

  • Negara asal:Jepun

  • Jenis Produk: PLC CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 90 mm x 66 mm x 70 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to provide compact and reliable control in localized industrial automation architectures, the Omron CPM1A-10CDT-A-V1 functions as a highly integrated micro-programmable logic controller. This unit combines memory, processing, and localized physical I/O within a single space-saving enclosure. Featuring 6 digital inputs and 4 transistor (sink) outputs, the controller is powered directly by an 85 to 264 VAC line supply, eliminating the need for external control power transformers in standard utility environments. Its integrated high-speed processing makes it optimal for localized machinery control, conveyor coordination, and dedicated subsystem execution.

Features

  • Integrated I/O Architecture: Features 10 onboard I/O points (6 inputs, 24 VDC; 4 transistor sink outputs) to handle basic sensing and actuation.
  • Universal AC Power Source: Operates reliably across a broad input range from 85 VAC to 264 VAC at 50/60 Hz.
  • Solid-State Outputs: Transistor (sink type) outputs allow high-frequency switching and reliable interfacing with electronic loads.
  • High-Speed Counters & Pulse Outputs: Equipped with 1 built-in encoder input (5 kHz) and 1 built-in pulse output (2 kHz) for entry-level positioning tasks.
  • Optimized Program Space: Includes 2 kWords of program memory capacity and 1 kWord of data memory.

Applications

  • Conveyor Control Systems: Manages localized sensor feedback, sorting gates, and speed indicators.
  • Packaging Equipment: Ideal for small form-fill-seal machines, labelers, and wrapper control loops.
  • HVAC Panel Integration: Controls pump sequencing, damper actuators, and fan operational cycles.
  • Specialized Machine Tools: Coordinates simple automated drills, pneumatic clamps, and feed mechanisms.

Technical Specifications

Parameter Specification Value
Manufacturer Omron Industrial Automation
Model Number CPM1A-10CDT-A-V1
Product Series CPM1A
Input Points 6 Inputs (24 VDC)
Output Points 4 Outputs (Transistor, Sink)
Power Supply Voltage 85 to 264 VAC (50/60 Hz)
Program Memory Capacity 2 kWords
Data Memory Capacity 1 kWords
Logic Execution Speed 0.72 us to 1.72 us (basic instructions)
High-Speed Inputs 1 Encoder/Counter Input (5 kHz)
Pulse Outputs 1 Pulse Output (2 kHz)
Expansion Support No (10-point micro blocks do not support I/O expansion)
Dimensions (H x W x D) 90 mm x 66 mm x 70 mm
Shipping Weight (Calculated) 0.45 kg

Connections and Interfaces

Terminal designation Functional Assignment
L1, L2/N AC Power Supply Inputs (85 to 264 VAC)
COM (Input) Common terminal for external 24 VDC input sensors
00.00 to 00.05 DC Input Terminals (00.00 dedicated to High-Speed Counter/Encoder input)
OUT V- (COM) Negative common for transistor sink outputs
10.00 to 10.03 Transistor Sink Output Terminals (10.00 dedicated to high-speed pulse output)

Empirical Engineering Insights

Alternative Models & Compatibility

The CPM1A-10CDT-A-V1 replaces the non-V1 legacy CPM1A units directly. The V1 variant offers expanded internal command support and refined serial polling response characteristics. Note that because this is a 10-point module, it lacks the peripheral expansion bus connection found on the 20-point and larger CPU models; thus, I/O scaling requires replacement with a larger base CPU unit rather than adding expansion slices.

Application Pitfalls & Engineering Notes

When using the built-in transistor sink outputs (model designation "T"), pay strict attention to the cumulative current draw. Each output is rated for up to 0.3 A individually, but the total current passing through the common return bus must not exceed 0.9 A. Exceeding this thermal threshold will permanently damage the internal logic boards. If your application switches inductive DC solenoids, always install external flyback diodes across the loads to prevent destructive back-EMF spikes.

Commissioning & Wiring Tips

To utilize the high-speed 5 kHz encoder functionality on input terminal 00.00, use double-shielded twisted-pair cabling. Route this cable completely separate from the AC supply lines wired to terminals L1 and L2/N to avoid electrical noise coupling. Additionally, connect the frame ground terminal directly to a clean low-impedance earth ground to prevent internal memory register corruption caused by high-frequency electromagnetic interference.

Installation Guidelines

CRITICAL WARNING: Ensure all main AC power is fully de-energized at the isolation breaker prior to handling terminal connections. Allow at least 60 seconds after power down for internal capacitors to discharge completely before making adjustments to the wiring harness or connection ports.
1

Mount the controller onto a standard 35 mm DIN rail inside an enclosure rated at least IP54 to prevent atmospheric dust and condensation contamination.

2

Connect the primary AC line voltage (85 to 264 VAC) directly to the L1 and L2/N terminals using 1.25 mm square (16 AWG) copper wire.

3

Wire field input devices to terminals 00.00 through 00.05, and provide a stable external 24 VDC potential to the input common terminal.

4

Verify that the output wiring polarity matches standard sink configurations, ensuring the common output ground is correctly established prior to system startup.

Loading product navigation…

What is the primary difference between the CPM1A-10CDT-A-V1 and older CPM1A modules?

The V1 suffix designates an updated firmware release that improves instruction execution stability, expands program verification support, and ensures seamless integration with newer CX-Programmer versions.

Can I expand the I/O point count on the CPM1A-10CDT-A-V1?

No. The 10-point micro PLC variant does not possess the physical expansion bus interface. For applications requiring I/O expansion, select a 20-point or higher CPM1A CPU module.

What are the limits on the transistor sink outputs for this PLC?

Each transistor output supports a maximum of 0.3 A at 24 VDC. Additionally, the cumulative load current across all four transistor outputs must not exceed 0.9 A to prevent internal track damage.

Does this model support high-speed counter functions?

Yes. This model has a built-in high-speed counter function supporting up to 5 kHz on physical input terminal 00.00, suitable for single-phase encoder feedback loops.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...