1 daripada 1

Omron H8PS-16BP Cam Positioner

Omron H8PS-16BP Cam Positioner

Hanya 6 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: H8PS-16BP

  • Negara asal:Jepun

  • Jenis Produk: Cam Positioners

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 96 mm x 96 mm x 67.5 mm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to execute high-speed, high-precision timing control in rotary automation applications, the Omron H8PS-16BP Cam Positioner coordinates mechanical operations via real-time rotary encoder tracking. This 1/4 DIN panel-mount controller serves as a solid-state replacement for mechanical cam switches, eliminating physical wear and reducing system maintenance downtime. Equipped with 16 PNP transistor outputs, the H8PS-16BP allows operators to precisely program ON/OFF angles to match specific mechanical cycles. The integrated back-lit LCD provides clear operational feedback, while standard front-panel keys and an intuitive DIP switch permit rapid configuration of encoder rotation directions (CW/CCW) directly on the factory floor.

Features

  • 16 PNP Transistor Outputs: High-density solid-state output bank configured for industrial PNP control circuits.
  • Hardware Rotation Switching: Integrated DIP switch simplifies encoder direction adaptation between forward (CW) and reverse (CCW) modes.
  • Compact 1/4 DIN Form Factor: Standard 96 x 96 mm front panel profile ensures straightforward integration into existing control enclosures.
  • High-Visibility Backlit LCD: Ensures clear monitoring of current angles, speed, and active step parameters in dimly lit industrial environments.
  • On-Panel Mounting Design: Designed for flush-mounting on control panels with minimal depth footprint behind the door.

Applications

  • High-Speed Packaging Machinery: Synchronization of sealing jaws, film feeding, and product ejectors.
  • Stamping and Press Control: Precise timing coordination for material feeders, lubrication systems, and safety light curtains relative to crank angle.
  • Rotary Indexing Tables: Step-by-step position validation and tool actuation timing.
  • Assembly and Cartoning Systems: Timing sequence coordination for pneumatic cylinders and pick-and-place mechanisms.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model / SKU H8PS-16BP
Device Type Cam Positioner
Supply Voltage 20.4 to 26.4 V
Input Configuration Absolute Rotary Encoder
Output Type PNP Transistor
Number of Outputs 16 Channels
Housing Size 1/4 DIN (96 x 96 mm)
Dimensions (W x H x D) 96 mm x 96 mm x 67.5 mm
Display Technology LCD with Backlight
Installation Method On-Panel (Flush Mount)
Device Weight Approximately 300 g
Shipping Weight 1.5 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The Omron H8PS series features distinct output topologies. Note that the H8PS-16BP variant utilizes PNP transistor outputs, making it the required replacement for sourcing-type logic configurations. If you are replacing an older NPN variant (such as the standard H8PS-16B), you must verify that the downstream PLC input cards or relays are updated to support the active-high PNP current output architecture. Ensure that the dedicated absolute encoder model matches the resolution configured on the H8PS controller before system startup.

Application Pitfalls & Engineering Notes

When deploying the cam positioner in high-vibration applications, ensure the panel mounting brackets are evenly torqued to avoid warping the outer plastic frame. A critical application limitation involves the encoder cable length: excessive runs without proper shielding can introduce signal propagation delays and high-frequency noise, which may manifest as sporadic angle mismatch faults. Always routing the encoder cable completely segregated from high-power 3-phase motor wiring prevents crosstalk.

Commissioning & Wiring Tips

Before powering up the system, confirm that the encoder rotation direction selection switch (DIP switch on the device) matches the physical mechanical rotation. Setting this parameter incorrectly will result in reversed angle calculations, potentially causing mechanical interference. Always ground the shielded encoder cable at the single dedicated terminal of the H8PS-16BP rather than at multiple points, preventing ground loop noise from corrupting high-frequency encoder pulse lines.

Installation Guidelines

CRITICAL ELECTRICAL SAFETY WARNING

Isolate and lock out all AC and auxiliary power sources feeding the control enclosure before mounting, wiring, or configuring the H8PS-16BP unit. High residual capacitive charges can exist on transistor output terminals. Verify complete de-energization using a calibrated multimeter prior to starting terminal termination.

1
Cut and Prep Panel: Create a 1/4 DIN cutout measuring exactly 92 x 92 mm in the panel door. Insert the H8PS-16BP from the front, ensuring the rubber gasket is seated flatly to maintain the panel's IP/NEMA ingress rating.
2
Secure Mounts: Tighten the physical mounting adapters on both sides of the controller until the unit is flush. Do not overtighten, as this can damage the terminal block tracking on the rear.
3
Connect Encoder & Power: Terminate the absolute encoder cable using the dedicated terminal assignments. Connect the main power supply (20.4 to 26.4 V) ensuring polarity is correct.
4
Initialize DIP Switches: Set the rotation direction switch (CW/CCW) to match your encoder mounting profile prior to initial calibration and programming.
Loading product navigation…

What is the primary difference between the H8PS-16B and the H8PS-16BP?

The H8PS-16B features NPN transistor outputs, whereas the H8PS-16BP provides PNP (sourcing) transistor outputs. It is critical to match this topology with your PLC or input relay design.

Does the H8PS-16BP support encoder direction switching on the fly?

No. Encoder rotation direction must be pre-set prior to operation using the physical hardware DIP switch located on the unit.

What type of encoder is compatible with the H8PS-16BP?

The unit is designed to interface with Omron absolute rotary encoders. Ensure the encoder resolution parameters align with the controller settings.

What should I do if the position readings appear reversed during startup?

De-energize the unit and change the DIP switch setting for encoder rotation direction (from CW to CCW or vice versa) to align the controller software tracking with physical mechanics.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Bekerja melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Pengembalian Wang .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan FBD PLC: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...