1 daripada 1

Omron G9SX-ADA222-T15-RC G9SX Series Flexible Safety Unit

Omron G9SX-ADA222-T15-RC G9SX Series Flexible Safety Unit

Hanya 7 item tinggal dalam stok
  • Pengilang: Omron

  • No. Produk: G9SX-ADA222-T15-RC

  • Negara asal:Jepun

  • Jenis Produk: Flexible Safety Units

  • Pembayaran: T/T, Western Union

  • Berat: 1500g

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Managing complex safety control loops across automated machinery requires robust logic processing, which the Omron G9SX-ADA222-T15-RC Advanced Safety Unit executes with solid-state precision. This flexible safety controller integrates logical AND connection functions to facilitate advanced safety networking across distributed modules without the need for a safety PLC. Outfitted with high-speed P-channel MOS FET transistor outputs, it delivers long operational life and eliminates the mechanical wear associated with traditional relay-based safety units.

Designed for flexible safety architectures, this device provides instantaneous and configured OFF-delayed outputs, supporting complex stop category requirements. The inclusion of modern spring-cage terminal blocks ensures reliable electrical contact under severe industrial vibrations, making it an ideal choice for high-vibration manufacturing and assembly environments.

Features

  • Advanced Logical Functions: Supports logical AND connections to link multiple safety units for coordinated stop sequences.
  • Dual Solid-State Output Types: Equipped with 2 instantaneous safety outputs and 2 OFF-delayed safety outputs for precise machine stop control.
  • Configurable OFF-Delay: Features a selectable OFF-delay timer adjustable up to 15 seconds.
  • Spring-Cage Terminals: Releasable spring-cage connection technology reduces wiring time and prevents loose connections caused by mechanical vibration.
  • Comprehensive Diagnostics: Integrated LED status indicators simplify troubleshooting by displaying safety input, feedback, and internal system error codes.

Applications

  • Robot Cells: Coordinated monitoring of emergency stop circuits, light curtains, and safety door interlocks.
  • High-Vibration Machinery: Packaging, material handling, and automotive assembly lines where terminal screw loosening is a hazard.
  • Multi-Zone Production Lines: Complex interlocked safety zones requiring logical AND connectivity between local guard circuits.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number G9SX-ADA222-T15-RC
Device Type Advanced Safety Unit
Rated Supply Voltage 24 VDC
Operating Voltage Range -15% to 10% of rated supply voltage (20.4 to 26.4 VDC)
Power Consumption 4 W max.
Instantaneous Safety Outputs 2 semiconductor outputs (P-channel MOS FET)
OFF-Delayed Safety Outputs 2 semiconductor outputs (P-channel MOS FET)
Auxiliary Outputs 2 semiconductor outputs (PNP transistor, 100 mA max.)
Max. OFF-Delay Time 15 seconds
Output Load Current (Safety) Using 2 outputs or less: 1.0 A DC max. / Using 3 outputs or more: 0.8 A DC max.
Safety Input Impedance Approx. 2.8 kohms
Terminal Connection Type Spring-cage (tension clamp)
Vibration Resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Weight 0.2 kg
Shipping Weight (Calculated) 1.5 kg (including structural export packaging)

Empirical Engineering Insights

Based on field commissioning experiences, several critical system-level factors should be accounted for during design and deployment:

Alternative Models & Compatibility

The "RC" in the model designation indicates spring-cage terminals. If replacing an older "RT" screw-terminal version, the internal logical circuit, diagnostics, and auxiliary output wiring configurations remain completely identical. This allows for a direct hot-swap of the unit body if maintaining the same base wiring layout, but require verifying terminal header compatibility.

Application Pitfalls & Engineering Notes

Because safety outputs are solid-state P-channel MOS FETs, they exhibit a small OFF-state leakage current. When interfacing these safety outputs with highly sensitive PLC digital inputs or micro-relays, ensure the input load draws enough current to pull the voltage below the downstream device's OFF threshold. Additionally, when using multiple units in close proximity within unventilated panels, keep a 10 mm lateral gap to prevent heat build-up when running at maximum auxiliary and safety output current ratings.

Commissioning & Wiring Tips

When configuring logical AND connections between multiple G9SX units, ensure the communication lines linked to L1 and L2 terminals are properly shielded and kept away from high-voltage motor cables to avoid noise-induced safety trips. Ensure the feedback and reset loop (terminals T31, T32 for manual reset, or T31, T33 for auto reset) has verified contact continuity before energizing the module; a startup mismatch will trigger an internal loop fault, locking out the unit.

Installation Guidelines

CRITICAL WARNING: ELECTRICAL HAZARD

Always isolate all primary power distribution circuits and auxiliary supply voltages before mounting, wiring, or configuring safety systems. Solid-state outputs can retain charge under specific circuit failure modes. Verify zero potential on all terminals before commencing physical maintenance.

1
Snap-mount the G9SX module onto a standard 35 mm symmetric DIN rail (IEC/EN 60715), ensuring the locking clip is securely engaged.
2
Insert pre-stripped or ferruled 24 AWG to 16 AWG signal cables directly into the spring-cage terminals. Press the orange release buttons with a flat screwdriver if wire adjustment is required.
3
Configure the rotary switches on the front face of the unit to define the target OFF-delay time (up to 15 seconds) prior to applying 24 VDC power.
4
Power on the module and execute a function test of all interconnected guard loops, emergency buttons, and feedback monitoring circuits to confirm correct operation.
Loading product navigation…

What is the primary difference between the -RC and -RT models?

The -RC variant is built with vibration-resistant spring-cage terminals, allowing rapid wiring without tools. The -RT variant utilizes conventional screw terminal blocks.

How do you set the OFF-delay time on this safety module?

The OFF-delay time is adjusted using the physical rotary switches situated on the front panel of the unit, supporting values up to 15 seconds.

Can I connect this module directly to standard expansion units?

Yes, logical expansion units can be linked to this unit. The advanced unit handles logical AND evaluation for the safety outputs across all interconnected sub-modules.

Does this safety unit contain internal relay contacts?

No, it features high-durability semiconductor (P-channel MOS FET) outputs, reducing system response times and preventing mechanical contact wear.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Jepun

Produk yang Baru Dilihat

Pengetahuan teknikal

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...