1 daripada 1

Schneider Electric TM221C40R Modicon M221 Logic Controller

Schneider Electric TM221C40R Modicon M221 Logic Controller

Hanya 8 item tinggal dalam stok
  • Pengilang: Schneider Electric

  • No. Produk: TM221C40R

  • Negara asal:Perancis

  • Jenis Produk: PLC CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 830g

  • Dimensi: 21.1 cm x 14.1 cm x 11.4 cm

  • Pelabuhan penghantaran: Xiamen

  • Jaminan: 12 bulan

Kuantiti
Lihat butiran penuh

Description

Designed to handle centralized discrete automation tasks, the Schneider Electric TM221C40R serves as a high-density, AC-powered main processing unit within the Modicon M221 logic controller range. This compact base controller features 40 integrated discrete I/O channels, consisting of 24 digital inputs and 16 relay outputs, complemented by 2 high-speed analog inputs. Optimized for small-to-medium industrial architectures, it provides robust control capabilities while minimizing cabinet space usage.

Features

  • High-Density Discrete I/O: Built-in 24 discrete inputs (conforming to IEC 61131-2 Type 1) and 16 robust relay outputs.
  • Integrated Analog Inputs: Two onboard 0 to 10 V analog inputs for basic sensor integration without extra modules.
  • Flexible Communications: Features embedded RJ45 Ethernet, RJ45 serial link (RS232/RS485), and Mini-B USB programming ports.
  • Expandable Architecture: Supports Modicon TM3 expansion modules for additional I/O, safety, or communication configurations.
  • Memory Backup: Dedicated SD card slot for quick application transfer, data logging, and firmware updates.

Applications

  • Material Handling: Controls conveyor speeds, sorting systems, and small packaging machines.
  • Pumping and HVAC: Manages fluid levels, pressure loops, and fan control systems.
  • Machine Tool Automation: Integrates discrete sensor arrays and mechanical actuation switches.
  • Infrastructure Utilities: Ideal for distributed utility monitoring and auxiliary control panels.

Technical Specifications

Parameter Value / Rating
Manufacturer Schneider Electric
Product Range Modicon M221
Model / SKU TM221C40R
Supply Voltage Range 100 to 240 V AC
Discrete Input Count 24 (including 4 fast inputs)
Discrete Output Type Relay (Normally Open)
Discrete Output Count 16 Relay Outputs
Analog Input Range 2 inputs (0 to 10 V), 10-bit resolution
Relay Output Current 2 A per output (maximum)
Programming Software EcoStruxure Machine Expert - Basic
Operating Temperature -10 to 55 degC (horizontal mounting)
Shipping Weight (Calculated) 0.83 kg
Package Dimensions (Calculated) 21.1 cm x 14.1 cm x 11.4 cm

Connections and Interfaces

Terminal / Port Assignment / Function
L, N AC Power Supply Mains Connection (100 to 240 V AC)
FG Functional Ground Connection
I0 to I23 Discrete Inputs (I0-I3 support High-Speed Counter functions)
Q0 to Q15 Relay Outputs (arranged in isolated common groups)
AI0, AI1, COM Analog Inputs (0 to 10 V) and shared Analog Common
Ethernet (RJ45) Modbus TCP client/server protocol access
Serial (RJ45) RS232/RS485 Serial Link communication configuration

Empirical Engineering Insights

Alternative Models & Compatibility

The TM221C40R directly replaces older Twido modular or compact controller configurations during system modernization. When translating applications from TwidoSuite or TwidoSoft to EcoStruxure Machine Expert - Basic, pay careful attention to memory allocation variables (%MW) and input mapping offsets, as slight syntax translations are required to prevent data collision.

Application Pitfalls & Engineering Notes

Thermal dissipation limits require vertical spacing clearance of at least 50 mm above and below the controller housing. If the unit is installed vertically (90-degree rotation), the maximum ambient rating drops from 55 degC to 35 degC. Additionally, ensure transient voltage suppressors (snubbers) are wired across inductive AC loads connected to the relay outputs to prevent premature contact pitting.

Commissioning & Wiring Tips

The 0 to 10 V analog inputs (AI0, AI1) share a single ground (COM) that is tied to the internal logic ground. Using unshielded cable on these inputs in high-EMI environments can lead to control signal jitter. Always run analog signals in shielded twisted-pair (STP) cabling, grounding the shield only at the controller end.

Installation Guidelines

CRITICAL WARNING

De-energize all primary and field sensor power distribution circuits before installing or removing terminals. Verify that all residual charge has fully bled down. Failure to isolate input power paths may result in severe electrical shock, system bus errors, or permanent circuit board damage.

1
Mount the controller onto a standard 35 mm DIN rail inside a protective NEMA or IP-rated electrical enclosure. Secure the top and bottom locking clips.
2
Wire the L and N terminal connections to an isolated 100-240 V AC supply line. Connect the FG terminal directly to the enclosure ground bus.
3
Connect your field discrete inputs and outputs to their corresponding terminal blocks, verifying that the output load currents do not exceed the 2 A limit per channel.
4
Insert the programmed SD card or connect the Mini-B USB cable to download the application parameters via EcoStruxure Machine Expert - Basic.
Loading product navigation…

What software is used to program the TM221C40R?

This controller is programmed using EcoStruxure Machine Expert - Basic (formerly known as SoMachine Basic), which is available as a free download from the manufacturer.

How does mounting orientation affect the operating temperature limits?

When mounted horizontally, the operating range is -10 to 55 degC. Vertical mounting reduces the maximum allowable operating temperature to 35 degC to maintain reliable internal cooling.

Are the analog inputs on the TM221C40R isolated?

No, the two built-in 0 to 10 V analog inputs share a common ground reference with the internal electronics. Shielded twisted-pair cables are recommended to avoid electrical noise.

What is the maximum rating for the integrated relay outputs?

The relay outputs are rated for a maximum thermal current of 2 A per output. Inductive AC loads should be protected with external RC snubber networks to prolong contact life.

Penghantaran Ekspres Global

  • Penghantaran Standard: 4-6 Hari Perniagaan melalui DHL, FedEx, dan UPS.
  • Penghantaran Ekspres: Penghantaran pada hari yang sama untuk pesanan dalam stok yang dibuat sebelum 2:00 PM (GMT+8).
  • Liputan Seluruh Dunia: Berkhidmat di lebih 150 negara, termasuk penghantaran pantas ke Arab Saudi dan UAE.

Pemulangan & Jaminan

  • Jaminan 30 Hari: Pemulangan diterima untuk produk dalam stok dalam pembungkusan asal yang disegel kilang.
  • Jaminan 12 Bulan: Setiap komponen industri disokong oleh jaminan teknikal profesional kami.

Pesanan diproses dan dihantar Isnin-Jumaat (tidak termasuk cuti umum).


Untuk kelayakan penuh, yuran penyimpanan semula, dan butiran pemulangan antarabangsa, sila lihat rasmi kami Polisi Pemulangan & Bayaran Balik .

TECHNICAL SPECIFICATIONS

Country of origin
Perancis

Produk yang Baru Dilihat

Pengetahuan teknikal

Penggerak Elektrik Direka untuk Menggantikan Sistem Kuasa Cecair: Panduan Automasi Industri Praktikal

Artikel ini menerangkan bagaimana aktuator elektrik bersepadu, seperti siri e-Actuator SMC, mengubah kawalan gerakan industri dengan menggantikan sistem pneumatik dan hidraulik tradisional. Ia...

Operasi Matematik Menggunakan OpenPLC untuk Aplikasi Automasi Industri

Artikel ini menerangkan bagaimana sistem PLC melaksanakan operasi matematik teras seperti penambahan, penolakan, pendaraban, pembahagian, modulo, dan perpangkatan dalam automasi industri. Ia...

Logik Boolean Lanjutan dengan Pengaturcaraan PLC FBD: Aplikasi Industri Praktikal Melebihi Logik Asas

Artikel ini menerangkan beberapa fungsi logik Boolean lanjutan yang digunakan dalam pengaturcaraan PLC selain operasi asas AND, OR, dan NOT. Ia merangkumi bagaimana alat seperti jadual kebenaran,...

Logik Boolean dalam Pengaturcaraan PLC: Memahami Pintu Logik FBD

Logik Boolean adalah asas bagi setiap program PLC. Dari kawalan mesin yang mudah hingga sistem automasi industri yang kompleks, pintu logik menentukan bagaimana pengawal bertindak balas terhadap...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan untuk Pengapit Robotik: Dari Pengendalian Halus hingga Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diilhamkan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang dikuasakan...