Yokogawa SDV144-S13 Digital Input Module ProSafe-RS

Yokogawa SDV144-S13 Digital Input Module ProSafe-RS

Only 10 item(s) left in stock
  • Manufacturer: Yokogawa

  • Product No.: SDV144-S13

  • Country of origin:Jepun

  • Product Type: Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 3.3cm x 10.7cm x 13cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Overview

The SDV144-S13 (SDV144-S13) is a high-reliability, 16-channel digital input module engineered for the Yokogawa ProSafe-RS Safety Instrumented System (SIS). As a crucial component in functional safety architectures, it is designed to monitor field device statuses—such as pressure switches, emergency stop buttons, and valve limit switches—in environments that require SIL3 (Safety Integrity Level 3) compliance. The "S13" suffix specifies the hardware style and revision, featuring a standard configuration without the conformal coating found on "C" variants, yet maintaining the same high-speed diagnostics and galvanic isolation required to protect the safety controller from field-side electrical surges. In the lifecycle of an LNG terminal or refinery, the SDV144-S13 ensures that safety-critical data is processed with deterministic precision to prevent catastrophic failures.

Technical Configuration

The module operates within the FIO (Field network I/O) node unit, utilizing a dual-microprocessor architecture to perform continuous self-tests on its internal circuitry. It supports Line Monitoring functionality, which allows the system to detect field wiring issues like open circuits or short circuits when used in conjunction with a resistor end-of-line (EOL) network. Each of the 16 channels is isolated from the internal system bus, providing a high degree of noise immunity and ensuring that a failure in one field loop does not propagate to the rest of the safety station.

Technical Specifications

Attribute Specification
Model SDV144-S13
Brand Yokogawa
System ProSafe-RS / Centum VP
Number of Channels 16 (Isolated)
Input Voltage 24 VDC
Safety Rating SIL3 (IEC 61508)
Input Current 4.1 mA (Typ. at 24 VDC)
ON Voltage 18 to 30 VDC
OFF Voltage 0 to 5 VDC
Weight 0.35 kg
Dimensions 13.0 x 4.0 x 13.0 cm
Operating Temp -20 to +70 deg C

Technical FAQs

What is the difference between the S13 and S33 revisions?

The S13 is an earlier hardware style code compared to the S33. While they are functionally similar, you must verify the "Style" compatibility in your Yokogawa Builder software. Often, a newer S33 can replace an S13, but the reverse may require a firmware downgrade or project reconfiguration.

Does this module support "Hot Swap" replacement?

Yes, the SDV144-S13 supports online module replacement (Hot Swap). When the system is running, you can pull the faulty module and insert a new one; the Safety Control Station (SCS) will automatically download the configuration parameters to the new unit.

How do I clear a "Line Fault" error on this module?

A Line Fault usually indicates a break or short in the field wiring. Check the 1 kOhm series and 10 kOhm parallel resistors at the field device. If the resistors are intact, inspect the terminal block connections for loose wires or corrosion.


Engineering & Installation Guide

  • EOL Resistor Placement: For safety loops requiring line monitoring, the resistors must be placed as close to the field contact as possible (e.g., inside the switch junction box). Placing them in the Marshalling Cabinet defeats the purpose of line monitoring, as it leaves the long field cable run unmonitored.

  • Redundancy Wiring: If you are using the SDV144-S13 in a redundant configuration (Dual-Redundant), ensure that the input signals are split correctly via a terminal board specifically designed for redundancy. Both modules must see the same input voltage simultaneously to avoid "Input Mismatch" alarms.

  • Grounding and Shielding: To ensure SIL3 reliability in high-EMI environments, the field cable shields should be grounded at the Marshalling Cabinet side only. Avoid "Double Grounding" which creates ground loops that can cause intermittent signal flickering on the 24 VDC digital inputs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Coklat Oren
Country of origin
Jepun
Power source
Kuasa DC

Recently Viewed Products

Technical knowledge

Panduan Mendalam tentang Firewall Industri dan Segmentasi Rangkaian OT

Firewall industri memainkan peranan penting dalam keselamatan siber OT, melindungi rangkaian PLC, DCS, dan SCADA melalui segmentasi, kawalan masuk/keluar, dan integrasi IDS/IPS yang selaras dengan...

Panduan Pengapit Robotik: Dari Pengendalian Halus ke Automasi Tugas Berat

Pengapit robotik moden sedang berkembang melebihi rahang mekanikal tradisional. Daripada sistem pelekat yang diinspirasikan oleh cicak dan pengapit lembut gred makanan hingga alat gudang yang...

Throwback: Bagaimana Motor Elektrik Awal Mengubah Perlombongan Bawah Tanah

Dari pemampat DC yang digerakkan tali ke troli lombong bertenaga bateri, operasi perlombongan awal menandakan titik perubahan dalam elektrifikasi industri. Artikel ini meneroka bagaimana motor...

Factory I/O: Alat Simulasi PLC Moden untuk Latihan Automasi Industri

Factory I/O sedang mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang mendalam untuk pelajar, jurutera, dan pasukan penyelenggaraan. Platform ini merapatkan jurang antara teori dan...

Pengaturcaraan Kitaran Gerakan Paksi Tunggal pada Pemacu Servo CMZ

Tutorial ini mengkaji bagaimana fungsi PLC terbina dalam pemacu servo CMZ SBD dapat melaksanakan program gerakan berdiri sendiri, termasuk logik homing, kawalan kedudukan, dan pergerakan paksi...

Persediaan Kawalan Gerakan Paksi Tunggal dengan Pemacu Servo CMZ

Tutorial ini meneroka penyediaan sistem gerakan servo paksi tunggal menggunakan pemacu CMZ SBD, merangkumi penyediaan perkakasan, penskalaan paksi, konfigurasi homing, dan pengesahan gerakan selamat...