Product Overview
The 05701-A-0328 is a high-reliability Analytics Relay Card designed for the Honeywell Analytics System 57 control system. This module is a core component of gas detection and monitoring architectures, providing the essential interface between the control system’s logic and external hardware devices. It is engineered to activate visual/audible alarms, ventilation fans, or emergency shutdown systems when gas concentrations exceed defined safety thresholds. Its robust design ensures failsafe performance in industrial environments where life safety and environmental protection are paramount.
Functional Logic & Safety Integrity
The 05701-A-0328 relay card provides multiple output channels that can be configured for various safety protocols. It operates by receiving processed signals from the System 57 control cards and translating them into physical contact closures. These relays are typically software-configurable for "Normally Energized" or "Normally De-energized" operation, allowing for "fail-to-safe" configurations. This flexibility makes the module suitable for a wide range of analytical applications, including combustible gas monitoring, toxic gas detection, and oxygen deficiency alerts.
Technical Specifications
| Attribute |
Specification Details |
| Model |
05701-A-0328 |
| Manufacturer |
Honeywell Analytics |
| Series |
System 57 |
| Product Type |
Analytics Relay Card |
| Output Type |
Electromechanical Relays (Dry Contacts) |
| Configuration |
Multi-channel / Field Configurable |
| Compatibility |
System 57 Rack Enclosures |
| Shipping Weight |
2.0 kg |
| Operating Environment |
Industrial Grade / Safety Critical |
Technical FAQs
Is the 05701-A-0328 compatible with all System 57 racks?
Yes, this relay card is designed to fit into the standard System 57 19-inch rack or half-rack enclosures. It utilizes the common backplane architecture of the System 57, allowing it to be easily integrated alongside existing sensor control cards.
Can the relays be configured for different alarm levels?
Absolutely. The 05701-A-0328 is usually programmed via the System 57 engineering interface to trigger based on specific alarm levels (e.g., A1, A2, or Fault). Each relay can be assigned to individual channels or grouped for common alarm notification.
Does this card support "Latching" alarm functions?
The latching functionality is typically managed by the system's control logic; however, the 05701-A-0328 is built to maintain its state as dictated by the controller. This ensures that critical safety events are recorded and maintained until a manual reset is performed by authorized personnel.
Field Engineering & Installation Guide
-
Backplane Connection: When inserting the 05701-A-0328, ensure the card guides are properly aligned with the rack slots. Press firmly to ensure the multi-pin connector is fully seated into the backplane to prevent intermittent relay chatter or communication faults.
-
Wiring Standards: Use high-quality, stranded copper wire for the relay contact terminals. Ensure that the voltage and current ratings of the external devices (fans, sirens, etc.) do not exceed the specific contact ratings of the card to prevent arcing and premature relay failure.
-
System Testing: After installation or replacement, it is vital to perform a functional "loop test." This involves simulating a gas alarm state to verify that the 05701-A-0328 correctly triggers the intended physical safety device.
Engineering Advantages
The 05701-A-0328 represents a critical link in the Honeywell Analytics safety chain. Its mechanical relay design provides physical isolation between the sensitive control electronics and high-power field devices, enhancing the overall system's electromagnetic compatibility (EMC). For B2B procurement, choosing the original Honeywell System 57 Relay Card ensures that the gas detection system maintains its original SIL (Safety Integrity Level) ratings and global safety certifications, providing peace of mind for facility managers and safety officers.