Product Overview

CI857K01 (3BSE018144R1) is an ABB AC 800M INSUM Ethernet Interface module designed for industrial communication between control systems and switchgear networks. It operates inside ABB 800xA and AC 800M architectures and supports reliable Ethernet-based data exchange for distributed automation systems.

This module is widely used in power generation plants, oil refineries, and heavy process industries where stable communication between controllers and motor control centers is critical. It reduces downtime by maintaining deterministic INSUM network communication under continuous load conditions.

Engineers deploy this interface to connect control processors with intelligent switchgear systems. It ensures consistent signal transmission in high-interference electrical environments. The module supports long lifecycle operation in both legacy and modern ABB control infrastructures.

Communication Architecture & Configuration

The CI857K01 module combines a CI857 communication interface with a TP853 baseplate for direct rack mounting in ABB systems.

It functions as an Ethernet gateway for INSUM communication, enabling real-time interaction between AC 800M controllers and distributed motor control systems. The module does not execute control logic but handles structured data exchange between field devices and central controllers.

The architecture supports scalable system expansion without additional protocol converters. It integrates natively into ABB 800xA environments and maintains stable performance in continuous industrial operation.

Technical Specifications

Item Specification
Model CI857K01
Order Code 3BSE018144R1
Brand ABB
Origin Sweden
Product Type Communication Module
Weight 0.7 kg
Dimensions 127.5 x 186 x 59 mm
Operating Temp 0 to 60 deg C
Power Consumption < 5 W (typical)
Network Type INSUM Ethernet
Mounting TP853 Baseplate

Technical FAQs

Is 3BSE018144R1 the same as CI857K01?
Yes. 3BSE018144R1 is the ABB order code, while CI857K01 is the functional type designation.

Where is this module typically installed?
It is installed in ABB AC 800M or 800xA control cabinets for INSUM communication.

Is CI857K01 still supported by ABB?
The module is marked obsolete but still widely used in installed base systems.

Can it integrate with modern Ethernet networks?
Yes, it operates within ABB INSUM Ethernet architecture but is not a general IT Ethernet device.

Engineering Installation Key Points

Installation of CI857K01 (3BSE018144R1) requires strict control of grounding, signal integrity, and module seating quality. Improper handling will directly cause INSUM communication instability or intermittent bus faults.

1. Baseplate Seating Integrity
Ensure TP853 baseplate is fully locked into the AC 800M rack. Partial engagement leads to unstable backplane communication and random module dropout under load.

2. Signal Grounding Discipline
Apply single-point grounding for Ethernet shield. Do not connect both ends of shield to cabinet ground. Multi-point grounding introduces loop current and distorts INSUM signal transmission.

3. Cable Routing Separation
Keep INSUM Ethernet cables physically separated from motor power cables and VFD output lines. Minimum separation distance should be maintained inside the cabinet to reduce electromagnetic coupling.

4. Insertion Alignment Control
Install CI857 module only after confirming perfect alignment with baseplate connectors. Forceful insertion under misalignment condition will damage backplane pins.

5. Thermal & Vibration Awareness
Avoid placing module near high-heat power supplies or high-vibration zones such as transformer compartments. Long-term exposure accelerates connector fatigue and communication errors.

6. Commissioning Check
After installation, verify Ethernet link stability and INSUM node recognition in controller diagnostics before bringing system online. Do not skip pre-energization validation.

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White Greyish White
Country of origin
Sweden

Technical knowledge

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...