The ABB S282UC-K10 miniature circuit breaker with Product ID GHS2820164R0427 is a 2-pole universal current protection device engineered to provide reliable current limitation and electrical fault security. As part of the S280UC product family, this device features a high direct current voltage rating, making it an excellent option for demanding DC configurations alongside standard AC systems. The unit incorporates two distinct internal tripping mechanisms: a delayed thermal tripping system calibrated for overload protection and an electromechanical magnetic assembly designed for immediate short-circuit interruption. Compliant with international standards including IEC/EN 60947-2, UL1077, and CSA 22.2 No. 235, this circuit breaker ensures safe and stable performance across specialized infrastructure systems.
| Parameter | Value |
|---|---|
| Extended Product Type | S282UC-K10 |
| Product ID | GHS2820164R0427 |
| EAN | 4012233637201 |
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Number of Poles | 2 |
| Tripping Characteristic | K |
| Rated Current (In) | 10.00 A |
| Rated Operational Voltage | acc. to IEC60898-1 440 V DC / 440 V AC / 484 V DC |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Operational Voltage | Maximum (incl. tolerance) 440 V AC / 484 V DC, Minimum 12 V AC / 12 V DC |
| Rated Frequency (f) | 50 Hz / 60 Hz |
| Rated Short-Circuit Capacity (Icn) | 6.0 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 6 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 6 kA |
| Overvoltage Category | II |
| Pollution Degree | 2 |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV (6.2 kV at Sea Level, 5.0 kV at 2000 m) |
| Dielectric Test Voltage | 50/60 Hz, 1 min: 2 kV |
| Housing Material | Insulation group I, RAL 7035 |
| Actuator Type | Insulation group II, black, sealable |
| Actuator Marking | 1/0 |
| Contact Position Indication | ON/OFF |
| Electrical Endurance | 10000 AC cycle |
| Mechanical Endurance | 20000 cycle |
| Terminal Type | Screw Terminals |
| Screw Terminal Type | Cable Clamp |
| Connecting Capacity | Busbar 16 mm² / Flexible with Ferrule 0.75 ... 16 mm² / Flexible 0.75 ... 16 mm² / Rigid 0.75 ... 25 mm² / Stranded 0.75 ... 25 mm² |
| Tightening Torque | 2.5 N-m |
| Recommended Screw Driver | Pozidriv 2 |
| Ambient Air Temperature | Operation -25 ... +55 Celsius / Storage -40 ... +70 Celsius |
| Environmental Conditions | 28 cycles with 55 Celsius at 90-96% and 25 Celsius at 95-100% |
| Resistance to Shock | acc. to IEC 60068-2-27: 30g / 3 shocks / 11 ms |
| Resistance to Vibrations | acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In |
| Degree of Protection | IP20 (IP40 inside enclosure with cover) |
| Maximum Operating Voltage UL/CSA | 500 V DC / 480 V AC |
| Connecting Capacity UL/CSA | Conductor 18 ... 4 AWG |
| Tightening Torque UL/CSA | Main Circuit 17.5 in lb |
| Interrupting Rating acc. to UL1077 | 4.5 kA |
| Product Net Width | 35.0 mm |
| Product Net Depth | 69.0 mm |
| Product Net Height | 90.0 mm |
| Product Net Weight | 0.260 kg |
Global Express Shipping
Returns & Warranty

The ABB S282UC-K10 miniature circuit breaker with Product ID GHS2820164R0427 is a 2-pole universal current protection device engineered to provide reliable current limitation and electrical fault security. As part of the S280UC product family, this device features a high direct current voltage rating, making it an excellent option for demanding DC configurations alongside standard AC systems. The unit incorporates two distinct internal tripping mechanisms: a delayed thermal tripping system calibrated for overload protection and an electromechanical magnetic assembly designed for immediate short-circuit interruption. Compliant with international standards including IEC/EN 60947-2, UL1077, and CSA 22.2 No. 235, this circuit breaker ensures safe and stable performance across specialized infrastructure systems.
| Parameter | Value |
|---|---|
| Extended Product Type | S282UC-K10 |
| Product ID | GHS2820164R0427 |
| EAN | 4012233637201 |
| Parameter | Specification |
|---|---|
| Manufacturer | ABB |
| Number of Poles | 2 |
| Tripping Characteristic | K |
| Rated Current (In) | 10.00 A |
| Rated Operational Voltage | acc. to IEC60898-1 440 V DC / 440 V AC / 484 V DC |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Operational Voltage | Maximum (incl. tolerance) 440 V AC / 484 V DC, Minimum 12 V AC / 12 V DC |
| Rated Frequency (f) | 50 Hz / 60 Hz |
| Rated Short-Circuit Capacity (Icn) | 6.0 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 6 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 6 kA |
| Overvoltage Category | II |
| Pollution Degree | 2 |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV (6.2 kV at Sea Level, 5.0 kV at 2000 m) |
| Dielectric Test Voltage | 50/60 Hz, 1 min: 2 kV |
| Housing Material | Insulation group I, RAL 7035 |
| Actuator Type | Insulation group II, black, sealable |
| Actuator Marking | 1/0 |
| Contact Position Indication | ON/OFF |
| Electrical Endurance | 10000 AC cycle |
| Mechanical Endurance | 20000 cycle |
| Terminal Type | Screw Terminals |
| Screw Terminal Type | Cable Clamp |
| Connecting Capacity | Busbar 16 mm² / Flexible with Ferrule 0.75 ... 16 mm² / Flexible 0.75 ... 16 mm² / Rigid 0.75 ... 25 mm² / Stranded 0.75 ... 25 mm² |
| Tightening Torque | 2.5 N-m |
| Recommended Screw Driver | Pozidriv 2 |
| Ambient Air Temperature | Operation -25 ... +55 Celsius / Storage -40 ... +70 Celsius |
| Environmental Conditions | 28 cycles with 55 Celsius at 90-96% and 25 Celsius at 95-100% |
| Resistance to Shock | acc. to IEC 60068-2-27: 30g / 3 shocks / 11 ms |
| Resistance to Vibrations | acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In |
| Degree of Protection | IP20 (IP40 inside enclosure with cover) |
| Maximum Operating Voltage UL/CSA | 500 V DC / 480 V AC |
| Connecting Capacity UL/CSA | Conductor 18 ... 4 AWG |
| Tightening Torque UL/CSA | Main Circuit 17.5 in lb |
| Interrupting Rating acc. to UL1077 | 4.5 kA |
| Product Net Width | 35.0 mm |
| Product Net Depth | 69.0 mm |
| Product Net Height | 90.0 mm |
| Product Net Weight | 0.260 kg |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Sweden
|