ABB

ABB SF810I-LOS-UVIR-T Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner

SKU SF810I-LOS-UVIR-T

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: ABB

  • Product No.: SF810I-LOS-UVIR-T

  • Country of origin:China

  • Product Type: Flame Scanners

  • Barcode: 9031809090

  • Payment: T/T, Western Union

  • Weight: 1372g

  • Dimensions: 180 mm x 135 mm x 260 mm (W x H x L)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The ABB SF810I-LOS-UVIR-T (SF810INT-LOS-UVIR-T-C-W ) is an advanced multi-fuel integrated safe flame scanner belonging to the Uvisor SF810i and Symphony Plus product families. This module acts as an integrated, self-contained intelligent combustion sensor, combining the optical detection assembly and the signal analysis processor within a single rugged enclosure. Engineered for challenging multi-fuel burners, it features dual-sensor detection capability utilizing both Ultraviolet (UV) and Infrared (IR) solid-state sensors to continuously monitor the presence or absence of individual burner flames. Beyond absolute flame discrimination, the device continuously analyzes flame modulation characteristics to compute real-time qualitative combustion stability trends. It features a Line-of-Sight (LOS) optical orientation, an internal termination board with plug-in terminal blocks, and an embedded Modbus RTU RS485 communication link for peripheral integration. Powered by a nominal 24 VDC input, the scanner operates without a separate remote evaluation unit, delivering safety-critical flame relay contacts and analog quality tracking outputs directly from the burner-mounted unit.

Features

  • Integrated all-in-one architecture housing both optical sensors and microprocessing electronics inside the burner head unit.
  • Dual solid-state UV and IR sensor arrangement designed for multi-fuel discrimination and coal, oil, or gas combustion profiling.
  • Line-of-Sight (LOS) optical orientation configuration for direct direct-view flame alignment.
  • Native electronic communication via built-in Modbus RTU over a 2-wire RS485 physical layer.
  • Direct on-board user configuration management accessible via raw Modbus registers or PC-based software utilities.
  • Internal terminal block module layout fitted with an integrated termination board for straightforward field wiring.

Applications

  • Multi-fuel utility burners using independent or simultaneous gas, oil, and pulverized coal firing.
  • Continuous flame supervision and discrimination within industrial steam boilers and power generation furnaces.
  • Real-time qualitative monitoring of flame combustion dynamics and burner performance.
  • Burner Management System (BMS) integration via direct hardwired flame safety relays.

Ordering Information

Detail Value / Description
Product ID SF810I-LOS-UVIR-T
Catalog Description SF810INT-LOS-UVIR-T-C-W
Invoice Description SF810INT-LOS-UVIR-T-C-W
Model Code Structure Integrated (SF810i), Line of Sight (LOS), UV + IR Sensors (UVIR), Terminal Block Termination (T)

Technical Specifications

Parameter Value / Specification
Manufacturer ABB
Product Family Uvisor SF810i Series (Integrated)
System Platform Symphony Plus
Sensing Technology Solid-state Ultraviolet (UV) + Infrared (IR)
Optical Configuration Line-of-Sight (LOS) / Direct View
Termination Type Plug-in terminal blocks via internal termination board
Serial Communication RS-485, 2-wire half-duplex
Communication Protocol Modbus RTU
Input Supply Voltage 24 V DC (Nominal)
Country of Origin China (CN)
Customs Tariff Number 9031809090
Product Net Width 7.087 in (180 mm)
Product Net Height 5.31 in (135 mm)
Product Net Length 10.236 in (260 mm)
Gross Weight 1.372 kg

Connections/Interfaces

Interface Option Function / Assignment
Internal Termination Board Provides plug-in screw terminal blocks for field conductor routing.
Flame Relay Contacts Independent hardwired output for direct safety-critical integration with the BMS.
Analog Output Channel Current loop configuration representing real-time flame signal quality metrics.
RS485 Serial Interface Two-wire connection supporting remote parameter alignment and diagnostic data fetch over Modbus RTU.

Installation Guidelines

  • Unscrew the housing access cover to expose the integrated internal termination board for conductor assignment.
  • Wire the power supply and communication paths to the plug-in terminal blocks, using shielded twisted-pair cables for the 2-wire RS485 Modbus network to minimize transient noise.
  • Mount the device onto the burner sight pipe via its designated Line-of-Sight mechanical flange link, aligning the assembly directly with the target primary combustion zone.
  • Apply low-pressure purging air to the cooling jacket assembly if operating in high thermal environments to protect the solid-state sensor window from soot buildup and overheating.

FAQ

What does the integrated design approach mean for the device installation?

The integrated design combines both the optical sensor array and the signal processing board into a single enclosure, meaning no standalone remote evaluation unit or separate control cabinet module is required.

Which sensor technologies are embedded in this specific model?

The device features a dual solid-state configuration consisting of both Ultraviolet (UV) and Infrared (IR) sensors, allowing accurate flame discrimination on burners firing multiple fuel types.

How are field cables connected inside the scanner enclosure?

Field wiring is handled via an internal termination board that features plug-in terminal blocks, accessible by opening the heavy-duty housing cover.

What local data and network communication protocols does the device support?

The device provides native serial communication supporting the standard Modbus RTU protocol over a 2-wire half-duplex RS-485 interface.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB SF810I-LOS-UVIR-T Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 2
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
China

Technical knowledge

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.