1 of 3

ABB SPICT13A Symphony Plus Infi-net to Computer Interface Module

ABB SPICT13A Symphony Plus Infi-net to Computer Interface Module

Only 4 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: SPICT13A

  • Country of origin:India

  • Product Type: DCS Communication Modules

  • Barcode: 8517620050

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 410 x 310 x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The ABB SPICT13A is a dedicated network communications interface board belonging to the Harmony Rack hardware family, engineered to interface an active Infi-net process bus directly with a host computer system. Functioning as a high-throughput Infi-net to Computer Interface Module (CIU), this industrial assembly establishes a reliable bridge for transferring raw control database structures, alarm tables, and high-frequency process variables to monitoring computers. By processing communications directly at the hardware layer with an architecture configured for zero processors, the module enables fluid supervisory visibility while shielding the continuous execution loops from commercial workstation packet handling latencies.

Features

  • Infi-net Communication Bridge: Direct physical layer link connecting plant-floor network rings to host computer systems.
  • Harmony Rack Integration: Tailored specifically for structural mating into standard S+ HR Series chassis assemblies.
  • Zero-Processor Hardware Layout: Optimized design minimizes processing latency by executing structural data routing configurations directly.
  • Industrial-Grade Component Sourcing: Constructed to endure the mechanical and thermal fluctuations typical of crowded instrumentation environments.

Applications

  • Supervisory data acquisition (SCADA) and human-machine interface (HMI) integration in Symphony Plus networks.
  • Real-time plant trend logging and diagnostic tracking across large-scale utility and power plant control setups.
  • Replacing worn or degraded interface cards to resolve persistent communication link loss faults between workstation PCs and control racks.

Technical Specifications

Parameter Value
Manufacturer ABB
Product Line Family Symphony Plus / Harmony Rack Hardware
Model ID SPICT13A
Functional Role S+ Infi-net to Computer Interface Module
Number of Processors 0
Customs Tariff Number 8517620050
Product Net Depth / Length 2.9 in (73.66 mm)
Product Net Height 14.2 in (360.68 mm)
Product Net Width 10.6 in (269.24 mm)
Product Net Weight 0.00 kg (Skeleton assembly basis)
Shipping Weight (Calculated) 1.50 kg (Gross Weight: 0.658 kg)
Package Dimensions (Calculated) 410 x 310 x 100 mm
Country of Origin India (IN)

Installation Guidelines

CRITICAL WARNING:

De-energize all electrical sources powering the target subrack before initiating card extraction or installation. Executing a swap while the backplane bus tracks are active can corrupt standard communication queues across the network ring and cause an absolute failure of the database connection to your host operating system.

1
Ground yourself using a validated ESD anti-static wrist strap connected directly to the unpainted steel ground rail of the control room cabinet enclosure.
2
Inspect the physical module track pathways to verify there is no dust contamination or pins out of alignment before introducing the new card.
3
Align the board along the guide tracks of the Harmony Rack slot and smoothly guide the board inward until the rear pins match and fully engage into the backplane housing sockets.
4
Lock down the integrated faceplate retaining components to maintain proper grounding contact, hook up the data cable going to the computer interface link, and apply rack system power.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB SPICT13A Symphony Plus Infi-net to Computer Interface Module

正在加载 PDF,请稍候…

What is the purpose of the SPICT13A module in a Symphony Plus framework?

This module operates as a direct computer interface unit, bridging data from the Infi-net control ring over to a host computer terminal for HMI visualization, data histories, or monitoring.

Does this interface board require a localized on-board processor configuration?

No, the board architecture features zero on-board processors, handling communications routing via direct hardware-layer data mapping parameters to maximize throughput speeds.

Can this communication board be handled without grounding precautions?

No. This module contains highly sensitive electro-static components. Grounding clips and proper ESD wrist straps must be used at all times during handling and installation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
India
Power source
DC Power

Recently Viewed Products

Technical knowledge

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...