Danfoss

AKV 20-4 (042H2027) Danfoss Electric Expansion Valve

SKU 042H2027

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 042H2027

  • Country of origin:United States

  • Product Type: Electric Expansion Valve

  • Payment: T/T, Western Union

  • Weight: 6000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The AKV 20-4 (042H2027) is a high-capacity, electronically operated expansion valve designed for precise liquid injection in industrial and commercial refrigeration plants. Utilizing the Pulse Width Modulation (PWM) principle, the Danfoss 042H2027 (042H2027) functions as both an expansion device and a liquid line solenoid valve, providing a tight shut-off when de-energized. This dual-purpose design is essential for B2B industrial applications such as large-scale cold storage, industrial chillers, and supermarket rack systems, where maintaining an exact superheat (SH) is critical for energy efficiency and compressor safety. The AKV 20-4 is engineered to provide higher mass flow rates than the AKV 20-1/2/3 models, making it suitable for high-output evaporator units.

Technical Configuration

The AKV 20-4 is built around a robust 13.5 mm actuator system and is typically driven by a Danfoss ADAP-KOOL controller. Rather than modulating the needle position, the valve cycles fully open and fully closed; the flow rate is determined by the duration of the "open" phase within the cycle. This mechanical simplicity results in a hermetic construction capable of withstanding millions of cycles without degradation. With a Maximum Working Pressure (PS) of 28 bar (406 psig), it is compatible with a wide range of HFC and HCFC refrigerants. The "Type 4" designation represents the specific high-capacity orifice size within the AKV 20 series framework.

Technical Specifications

Feature Specification
Model AKV 20-4 (042H2027)
Brand Danfoss
Product Type Electric Expansion Valve (PWM)
Actuator System 13.5 mm
Max Working Pressure (PS) 28 bar (406 psig)
Max Test Pressure 42 bar
Ambient Temp Range -40 to 50 Celsius
Function NC (Normally Closed)
Compatible Refrigerants R404A, R134a, R407C, R507, etc.
Weight 4.8 kg
Shipping Weight 6.0 kg

Technical FAQs

What are the specific advantages of PWM control for high-capacity systems?

In high-capacity systems, PWM control ensures that when the valve is open, the refrigerant velocity remains high. This assists in efficient oil return to the compressor and optimizes heat transfer within the evaporator by maintaining a consistent turbulence level, which is often superior to the partial-throttling found in mechanical valves.

Is an additional solenoid valve required for system safety?

No. The AKV 20-4 is a Normally Closed (NC) valve that provides a reliable, hermetic seal when the power is removed. This eliminates the hardware costs and pressure drops associated with installing an extra solenoid valve in the liquid line.

Can the internal orifice be replaced?

The AKV 20 series features a modular design where the orifice and needle assembly can be serviced or replaced if necessary, ensuring the valve body remains in place while restoring the valve to its original factory performance.


Engineering & Installation Guide

  • Upstream Filtration: Due to the rapid cycling nature of PWM valves, it is mandatory to install a high-quality filter drier (such as the Danfoss DML or DCL series) immediately before the valve. Debris in the liquid line can cause rapid wear on the valve seat or prevent the needle from sealing properly, leading to "flooding."

  • Brazing Thermal Protection: During installation of the solder connections, the valve body must be protected from excessive heat. Wrap the body in a wet cloth and ensure that the temperature of the 13.5 mm actuator housing does not exceed 100 Celsius. Overheating will damage the internal seals and the coil interface.

  • Electrical Configuration: Ensure the coil voltage matches the output of your Danfoss AK-CC or AKC controller. The coil must be mounted with the cable entry pointing downwards (creating a drip loop) to prevent moisture from traveling along the wire and into the actuator assembly.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Gold
Country of origin
United States
Power source
AC-powered

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.