The 1734-IE2C is a 2-channel analog current input module designed for integration within the POINT I/O system architecture. The 1734-IE2C provides conversion of 4...20 mA and 0...20 mA field signals into 16-bit digital representation for process control systems. The unit sends 6 bytes of input data and fault status information across the backplane to the system controller, operating via DeviceNet, PROFIBUS, ControlNet, or EtherNet/IP adapters.

Features

  • Provides 2 single-ended, non-isolated current input channels.
  • Supports configurable analog input ranges of 4...20 mA and 0...20 mA.
  • High-resolution 16-bit analog-to-digital conversion (0.32 uA/cnt) using Delta Sigma conversion.
  • Built-in channel status and fault indicators for local diagnostic monitoring.
  • Removable Terminal Block (RTB) compatibility allows module replacement without disconnecting field wiring.
  • Integrated fault protection up to 28.8V DC.

Applications

  • Industrial process automation and monitoring
  • 4...20 mA transmitter signal integration
  • Factory automation control systems using POINT I/O architectures
  • Remote I/O field signal acquisition

Technical Specifications

Attribute Specification
Manufacturer Allen-Bradley / Rockwell Automation
Model 1734-IE2C
Country of Origin Singapore
Dimensions (H x W x D) 56.6 x 12.1 x 77.5 mm (2.23 x 0.48 x 3.05 in.)
Weight 33 g (1.16 oz.)
Number of Inputs 2 single-ended, non-isolated, current
Input Current Range 4...20 mA, 0...20 mA
Resolution 16 bits - over 0...21 mA (0.32 uA/cnt)
Conversion Type Delta Sigma
Input Impedance / Resistance 160 ohms
Absolute Accuracy 0.1% Full Scale @ 25 degC (77 degF)
Accuracy Drift with Temp 30 ppm/degC
Digital Filter Time Constant 0...10,000 ms (default = 0 ms)
Input Update Rate 120 ms @ Notch = 50 Hz, 100 ms @ Notch = 60 Hz (default), 24 ms @ Notch = 250 Hz, 12 ms @ Notch = 500 Hz
Common Mode Rejection Ratio 120 dB
Normal Mode Rejection Ratio -60 dB
Maximum Overload Fault protected to 28.8V DC
External DC Power Supply Voltage 24V DC nominal (10...28.8V DC)
External DC Power Supply Current 15 mA @ 24V DC
POINTBus Current (Max) 75 mA @ 5V DC
Power Dissipation (Max) 0.6 W @ 28.8V DC
Thermal Dissipation (Max) 2.0 BTU/hr @ 28.8V DC
Isolation Voltage 50V continuous (tested to withstand 2550V DC for 60 s)
Keyswitch Position 3
Terminal Base Screw Torque 0.6 N-m (7 lb-in)
Wire Size 0.25...2.5 mm2 (22...14 AWG) solid or stranded shielded copper wire rated at 75 degC or greater
Operating Temperature -20 degC to +55 degC (-4 degF to +131 degF)
Storage Temperature -40 degC to +85 degC (-40 degF to +185 degF)
Relative Humidity 5...95% noncondensing

Connections/Interfaces

Terminal Pin Function
0 Current Input Channel 0 (In 0)
1 Current Input Channel 1 (In 1)
2 Chassis Ground (Chas Gnd)
3 Chassis Ground (Chas Gnd)
4 Common (C)
5 Common (C)
6 12/24V DC Supply (V)
7 12/24V DC Supply (V)

Installation Guidelines

  • Mounting Base Alignment: Mount the module into a compatible POINT I/O base assembly (1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S, 1734-TOP, 1734-TOPS, 1734-TOP3, or 1734-TOP3S). Set the keyswitch to position 3 prior to installation.
  • DIN Rail Grounding: Install onto a zinc-plated chromate-passivated steel DIN rail to ensure proper chassis grounding. Secure the DIN rail every 200 mm (7.8 in.).
  • Enclosure Requirements: Mount in an open-style industrial enclosure rated for Pollution Degree 2 environments and compliant with specific application requirements.
  • Electrostatic Discharge (ESD): Touch a grounded object or wear an approved grounding wrist strap before handling the electronics.
  • Wiring Practices: Use shielded copper wire rated for 75 degC or higher with a maximum insulation thickness of 1.2 mm (3/64 in.).

Compliance and Certifications

  • c-UL-us: UL Listed Industrial Control Equipment (UL File E65584); UL Listed for Class I Division 2 Groups A, B, C, D Hazardous Locations (UL File E194810).
  • UK / CE: Compliant with EMC Directive (2014/30/EU), LVD (2014/35/EU), and RoHS Directive (2011/65/EU).
  • ATEX: II 3G Ex ec IIC T4 Gc (DEMKO 04 ATEX 0330347X).
  • UKEX: UL22UKEX2478X.
  • IECEx: IECEx UL 20.0072X (Ex ec IIC T4 Gc).
  • RCM: Compliant with Australian Radiocommunications Act.
  • KC: Korean Registration of Broadcasting and Communications Equipment.
  • CCC: CNCA-C23-01 Certified Explosion-Proof Electrical Product (2020122309111607).
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen Bradley 1734-IE2C Point I/O 2 Point Analog Input Module

What is the recommended keyswitch position for installing the module?

The mechanical keyswitch on the mounting base must be rotated to position 3 before inserting the module.

What input signal types does the module support?

The module supports 2 single-ended, non-isolated current input channels configured for 4...20 mA or 0...20 mA signals.

Can field wiring remain attached when replacing the unit?

Yes, by utilizing a compatible Removable Terminal Block (RTB) base assembly, the module can be removed and replaced without disconnecting field wiring.

What is the operating temperature range for the device?

The device is rated for operation in surrounding air temperatures ranging from -20 degC to +55 degC.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Singapore

Recently Viewed Products

Technical knowledge

Modernizing Bailey INFI 90 Symphony HMIs Running on OpenVMS Alpha

A practical guide to replacing aging Bailey Symphony operator stations running on OpenVMS Alpha. It compares Alpha emulation, OpenVMS x86 migration, OPC re-platforming, and phased ABB modernization.

Why Maintenance Data Is Essential for Industrial Reliability

Maintenance data connects work orders, sensor signals, asset history, costs, and technician knowledge. Used well, it improves planning, reliability, predictive maintenance, spare-parts control, and...

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...