Allen-Bradley

Allen-Bradley 1756-IV16 ControlLogix Digital DC Input Module

SKU 1756-IV16

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 1756-IV16

  • Country of origin:United States

  • Product Type: Digital Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 90g

  • Dimensions: 145 mm x 35 mm x 130 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Allen Bradley 1756-IV16 is a ControlLogix digital DC sourcing input module. Designed for compatibility with the ControlLogix 1756 chassis system, this module receives discrete signal inputs from field devices and transfers input status to the system backplane. It requires a removable terminal block housing (RTB)—either the 1756-TBNH or 1756-TBSH—prior to mounting into the chassis. The 1756-IV16 provides 16 sourcing input channels configured in 2 groups of 8 points each, operating across a nominal supply voltage of 12/24V DC.

Features

  • 16 digital sourcing inputs organized into two groups of 8 points.
  • Operating DC voltage range from 10V DC to 30V DC.
  • Configurable off-to-on hardware input delay plus user-selectable digital filter options.
  • Optical isolation rating up to 250V continuous.
  • Compatible with 1756-TBNH and 1756-TBSH removable terminal blocks.

Applications

  • Factory automation discrete sensing and position detection.
  • Machine tool limit switch and proximity switch monitoring.
  • Material handling equipment status feedback.
  • Process control interlock and discrete event monitoring.

Technical Specifications

Parameter Specification
Manufacturer Allen Bradley
Product Line ControlLogix
Part Number 1756-IV16
UPC 612598264346
Module Type Digital DC Sourcing Input Module
Inputs 16 (8 points per group)
Voltage Category 12/24V DC source
Operating Voltage Range 10...30V DC
Nominal Input Voltage 24V DC
Off-State Voltage (Max) 5V DC
Off-State Current (Max) 1.5 mA
On-State Current (Min) 2 mA @ 10V DC
On-State Current (Max) 10 mA @ 30V DC
Inrush Current (Max) 250 mA
Input Impedance (Max) 3.2 kohm @ 30V DC
Input Delay Time (Off to On) Hardware delay: 280 us nom / 1 ms max + filter time (0 ms, 1 ms, or 2 ms)
Input Delay Time (On to Off) Hardware delay: 540 us nom / 2 ms max + filter time (1 ms, 2 ms, 9 ms, or 18 ms)
Backplane Current @ 5.1V 110 mA
Backplane Current @ 24V 2 mA
Total Backplane Power 0.61 W
Power Dissipation (Max) 5.1 W @ 60 degC
Thermal Dissipation 18.47 BTU/hr
Isolation Voltage 250V continuous
Removable Terminal Block Housing 1756-TBNH, 1756-TBSH
Weight 0.09 kg (0.19 lbs)

Installation Guidelines

  • Ensure system power and backplane power are removed before installing or removing the module.
  • Securely wire field devices to the compatible 1756-TBNH or 1756-TBSH Removable Terminal Block (RTB) according to standard industrial wiring practices.
  • Align the module with the chassis slot guides and push firmly until the module latches into the ControlLogix backplane.
  • Route signal wiring away from high-voltage AC lines and high-frequency noise sources to mitigate EMI/RFI interference.
  • Maintain proper panel ventilation to prevent operating ambient temperatures from exceeding 60 degC.

FAQ

What RTB housing is compatible with the module?

The module requires either a 1756-TBNH or 1756-TBSH removable terminal block housing to connect field wiring.

What is the operating voltage range for the device?

The device operates within a voltage range of 10 to 30 Volts DC.

How many input points are available on the module?

The module provides 16 digital sourcing inputs arranged into two groups of 8 points each.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1756-IV16 ControlLogix Digital DC Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.

Replacing an Allen-Bradley 1785-L40B: PLC-5/40 Checks Before Migration

A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.

Allen-Bradley 1747-SN: RIO Mapping and Link Fault Checks

Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.