Allen-Bradley

Allen-Bradley 2711-T10C20 PanelView 1000 Color Operator Interface Terminal

SKU 2711-T10C20

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Allen-Bradley

  • Product No.: 2711-T10C20

  • Country of origin:United States

  • Product Type: Operator Interface Terminal

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Overview

The Allen-Bradley 2711-T10C20 is a PanelView 1000 color touchscreen terminal.

The recorded specification includes a 640 × 480 TFT display, 1,008 KB flash memory, 85–264 VAC input, and 18–32 VDC input.

Features

  • 10-inch analog-resistive color touchscreen interface for intuitive operator control and monitoring.
  • Active-matrix TFT display with a resolution of 640 x 480 pixels for clear visual feedback.
  • Integrated communication port supporting high-speed data transfer and controller connectivity.
  • Application flash memory configured for storing extensive operator screens and alarm configurations.
  • Dual power supply options supporting AC and DC voltage ranges for flexible installation.
  • Rugged front-panel enclosure rating designed to withstand industrial washdown and particulate conditions when properly panel-mounted.

Technical Specifications

Parameter Specification
Manufacturer Allen-Bradley / Rockwell Automation
Product Line PanelView 1000
Catalog Number 2711-T10C20
Display Type Color TFT Active-Matrix, Analog-Resistive Touchscreen
Display Size 10 inches (8.3 x 6.2 in / 211 x 158 mm active display area)
Resolution 640 x 480 pixels
Application Memory 1008 KB Flash memory
AC Power Supply Rating 85 to 264 VAC (47 to 63 Hz)
AC Power Consumption 55 VA maximum
DC Power Supply Rating 18 to 32 VDC (24 VDC nominal)
DC Power Consumption 24 W maximum (1.0 A at 24 VDC)
Enclosure Rating NEMA Type 12, 13, 4X (Indoor use only); IP54, IP65 (front panel)
Operating Temperature 0 to 50 degC (32 to 131 degF)
Country of Origin United States

Connections / Interfaces

The terminal features standard communication ports located on the rear chassis for PLC connectivity and peripheral devices. Built-in network ports facilitate communication with compatible control systems, while auxiliary ports support terminal configuration, printing, and file transfers.

FAQ

What is the Allen-Bradley 2711-T10C20 and what are its primary uses?

The Allen-Bradley 2711-T10C20 is a PanelView 1000 color operator interface terminal designed to provide robust visualization and control in industrial automation environments. It features a 10-inch active-matrix TFT display with an analog-resistive touchscreen for direct operator interaction, machine status monitoring, and alarm logging. This HMI integrates seamlessly into discrete manufacturing and process control systems to optimize plant floor efficiency.

What type of display and resolution does this operator terminal use?

The Allen-Bradley 2711-T10C20 PanelView 1000 utilizes an active-matrix thin-film-transistor (TFT) color display with a resolution of 640 x 480 pixels. The 10-inch screen provides clear visual feedback for complex automation tasks and recipe management. Additionally, the integrated analog-resistive touchscreen allows operators to easily input commands and monitor real-time data.

What are the power supply specifications for the 2711-T10C20 terminal?

The Allen-Bradley 2711-T10C20 PanelView 1000 supports versatile power configurations to suit various control cabinet requirements. For AC installations, it operates on a rating of 85 to 264 VAC at 47 to 63 Hz with a maximum consumption of 55 VA. For DC installations, it accommodates 18 to 32 VDC with a nominal 24 VDC rating and a maximum consumption of 24 W.

What environmental and enclosure ratings does the unit maintain?

The Allen-Bradley 2711-T10C20 PanelView 1000 maintains strict environmental sealing standards with front-panel ratings of NEMA Type 12, 13, and 4X for indoor use, along with IP54 and IP65 protections. These rugged enclosure ratings ensure the unit withstands industrial washdown conditions and particulate environments when properly panel-mounted. It is designed to operate reliably within an ambient temperature range of 0 to 50 degrees Celsius.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 13 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.