The Allen-Bradley 1756-L55M22 is a ControlLogix5555 programmable automation controller designed for high-performance industrial control and processing application tasks within a ControlLogix system chassis. The controller manages system execution, data logic, and communication functions across connected devices, utilizing nonvolatile memory capabilities alongside dedicated data and logic memory. Communication interfaces include an integrated RS-232 serial port for workstation connectivity and diagnostic interactions. Designed as part of the ControlLogix family, the 1756-L55M22 operates inside open-style chassis enclosures for process control, discrete control, and automated machinery installations.
Features
Provides 750 KB of data and logic memory along with 208 KB of I/O memory.
Supports nonvolatile memory functionality for program and data protection.
Features an integrated RS-232 serial communication port for serial connection and programming.
Mounts into any available slot of a ControlLogix chassis.
Equipped with front-panel LED status indicators including RUN, I/O, FORCE, RS232, BAT, and OK.
Features a three-position mode selection keyswitch (RUN, REM, PROG).
Applications
Industrial process control systems
Automated manufacturing machinery
Distributed I/O control architectures
Machine automation and monitoring
Technical Specifications
Attribute
Value
Model
1756-L55M22
Series
A
Data and Logic Memory
750 KB
I/O Memory
208 KB
Nonvolatile Memory
Yes
Backplane Current (5.1V DC)
1.23 A
Backplane Current (24V DC)
0.014 A
Power Dissipation
5.6 W
Thermal Dissipation
19.1 BTU/hr
Weight, approx.
0.35 kg (12.5 oz)
Operating Temperature
0 to 60 degC (32 to 140 degF)
Storage Temperature
-40 to 85 degC (-40 to 185 degF)
Relative Humidity
5 to 95% noncondensing
Operating Vibration
2 g @ 10 to 500 Hz
Operating Shock
30 g
Nonoperating Shock
50 g
Enclosure Type Rating
None, open style
Isolation Voltage
30V (continuous), Basic Insulation Type, RS232 to system
Programming Cable
1756-CP3 or 1747-CP3 serial cable
North American Temp Code
T4A
IEC Temp Code
T4
Intrinsically Safe
No
Replacement Battery
1756-BA1
Connections/Interfaces
Connector Pin
Function
Pin 1
CD (Data Carrier Detect)
Pin 2
RXD (Receive Data)
Pin 3
TXD (Transmit Data)
Pin 4
DTR (Data Terminal Ready)
Pin 5
GND (Common)
Pin 6
DSR (Data Set Ready)
Pin 7
RTS (Request to Send)
Pin 8
CTS (Clear to Send)
Pin 9
N/C (Not Connected)
Installation Guidelines
Ensure backplane power is removed or the area is known to be nonhazardous prior to inserting or removing the controller or connecting cables.
Discharge potential static by wearing an approved grounding wriststrap and touching a grounded object before handling the module.
Mount the equipment inside a suitably designed open-type enclosure complying with appropriate flame-retardant ratings and accessible only with a tool.
Connect the 1756-BA1 battery correctly prior to placing the controller in service.
Align the module circuit board with top and bottom chassis guides and slide into the chassis slot until fully engaged.
Limit custom serial cable lengths to a maximum of 15.2 m (50 ft) and attach the shield at both ends.
Compliance and Certifications
UL Listed Industrial Control Equipment (UL File E65584)
CSA Certified Process Control Equipment (CSA File LR54689C)
CSA Certified Process Control Equipment for Class I, Division 2 Group A, B, C, D Hazardous Locations (CSA File LR69960C)
European Union 2004/108/IEC EMC Directive (EN 61326-1, EN 61000-6-2, EN 61000-6-4, EN 61131-2)
C-Tick Australian Radiocommunications Act (AS/NZS CISPR 11)
European Union 94/9/EC ATEX Directive (EN 60079-15, Zone 2)
FAQ
What memory capacity is provided by the module?
The module provides 750 KB of data and logic memory, 208 KB of I/O memory, and supports nonvolatile memory.
Which serial cables are compatible with the controller RS-232 port?
The controller connects using a 1756-CP3 or 1747-CP3 serial cable, or a custom cable limited to a maximum length of 15.2 m (50 ft).
What battery is required for backup power on this device?
The device uses a 1756-BA1 replacement battery or a 1756-BATM battery module.
A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.
A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.
A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.
A field-focused checklist for replacing an Allen-Bradley 1785-L40B or planning a PLC-5/40 migration, covering backups, 1771 I/O mapping, DH+/RIO channels, revision risks and commissioning.
Replacing an Allen-Bradley 1747-SN scanner? Check SLC 500 logical rack and G-file mapping, link speed, cable termination, COMM/FAULT LEDs and hardware series before blaming the module or changing the...