B&R

B&R X20AI4622 X20 Series Analog Input Module

SKU X20AI4622

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: B&R

  • Product No.: X20AI4622

  • Country of origin:United States

  • Product Type: Control systems

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The B&R X20AI4622 (X20 AI 4622) is a high-performance analog input module designed for precision process monitoring within the B&R X20 automation system. Engineered for demanding industrial environments—including power generation plants, chemical processing facilities, and automated manufacturing lines—this module provides 4 differential inputs capable of handling both current and voltage signals. By delivering reliable, high-resolution signal acquisition, the X20AI4622 significantly reduces sensor-to-controller latency and mitigates the risk of unscheduled downtime caused by signal inaccuracies. Its compact design and modular architecture ensure seamless integration into existing control cabinets, providing the robust data fidelity required for complex closed-loop control applications.

Technical Configuration

The module features a high-precision 13-bit digital converter (including sign) based on the Successive Approximation Register (SAR) conversion procedure. It is built for versatility, allowing the user to switch between voltage (plus/minus 10 V) and current (0 to 20 mA or 4 to 20 mA) modes simply by selecting the appropriate terminal connection points. The module is engineered with a 3rd-order low-pass input filter with a cutoff frequency of 1 kHz to eliminate high-frequency noise from industrial machinery. Electrical isolation is provided between the I/O channels and the backplane bus, protecting the CPU and downstream processing components from potential transients. Status monitoring is comprehensive, with integrated LEDs for channel-specific I/O functions and module-wide error diagnostics accessible via software.

Technical Specifications

Feature Specification
Model X20AI4622
Brand B&R
Analog Inputs 4 Differential
Resolution 13-bit (including sign)
Conversion Time 400 microseconds
Input Impedance (Voltage) 20 MOhm
Input Protection Max plus/minus 30 V (Voltage) / Max plus/minus 50 mA (Current)
Bus Power Consumption 0.01 W
Internal I/O Power 1.1 W
Operating Temperature -25 to 60 deg C (Horizontal)
Protection Rating IP20
Weight 1.0 kg

FAQs

Is the X20AI4622 compatible with all X20 series backplanes?

Yes, it is designed for the standard X20 system architecture, but you must order the X20BM11 bus module and X20TB12 terminal block separately as they are not included with the module.

How do I switch between voltage and current input modes?

The selection is hardware-dependent. You must wire the input signal to the specific terminal points designated for either voltage or current mode as outlined in the B&R user manual.

What is the recommended procedure if the module reports an overload?

The module is equipped with configurable diagnostics. When an overload is detected, the output of the digital value can be set via software configuration; check your software project settings to ensure the error-handling behavior matches your safety requirements.

Installation and Operational Guidelines

  • Wiring and Shielding: To ensure maximum signal integrity, always use shielded twisted-pair cables for analog signals. Ground the cable shield at one point—preferably at the entry to the control cabinet—to prevent ground loops that could interfere with the 13-bit conversion precision.
  • Thermal Management: When mounting the module in a cabinet, ensure a clearance of at least 12.5 mm to allow for proper airflow. If the installation altitude exceeds 2000 m above sea level, ensure the ambient temperature rating is derated by 0.5 deg C per 100 m to prevent thermal fatigue of the internal components.
  • Terminal Safety: The X20AI4622 is rated for hazardous locations (Class I, Division 2). Before servicing, ensure the environment is free of flammable gas concentrations and verify that the module is powered down before removing it from the X20BM11 bus module to prevent arcing.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...