B&R

B&R X20AP3131 X20 System 3-Phase Energy Metering Module

SKU X20AP3131

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: B&R

  • Product No.: X20AP3131

  • Country of origin:United States

  • Product Type: Energy Metering Module

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The X20AP3131 (X20AP3131) is an industrial-grade three-phase energy metering module engineered for the modular B&R X20 System platform. Designed to provide real-time power analytics in high-consumption industrial sectors—such as automotive plants, paper mills, data centers, and heavy processing facilities—this advanced module measures and processes main power distribution networks up to 480 VAC at 50/60 Hz. By executing high-speed onboard mathematical algorithms, the hardware directly calculates active (effective), reactive, and apparent power and energy metrics, alongside true root-mean-square (RMS) values. Integrating this specialized module into your automation grid optimizes sub-billing transparency, supports peak-shaving energy strategies, and detects phase imbalances before they damage downstream multi-axis drive machinery.

Technical Configuration

This metering component incorporates a specialized physical housing variant that is 240 V keyed, preventing accidental mechanical insertion into low-voltage sensor terminal slots and shielding the local I/O node from severe cross-voltage damage. The module features 3 high-voltage analog inputs for direct phase voltage acquisition and 4 precision analog inputs rated for 5 A AC current transformer (CT) secondary loops.

A core performance feature of the module is its integration with the B&R NetTime microsecond synchronization function. This distributed clock mechanism timestamps power measurements with high precision across the system network, allowing engineers to correlate transient voltage sags or peak current spikes directly with specific mechanical axis movements logged on remote drives. The fourth current channel is specifically allocated for neutral-conductor current measurement, ensuring comprehensive vector calculation of unbalance states in non-linear industrial loading environments.

Technical Specifications

Attribute Specifications
Model X20AP3131
Brand B&R (Bernecker + Rainer)
Module Category X20 System Power and Energy Metering
Voltage Channels 3 Analog Inputs (Phase-to-Neutral / Phase-to-Phase)
Nominal Voltage Rating Up to 480 VAC
Current Channels 4 Analog Inputs (3 Phases + 1 Neutral)
Nominal Current Rating 5 A AC (Suitable for external current transformers)
Grid Frequency 50 / 60 Hz
Onboard Calculations Effective (Active), Reactive, Apparent Power; RMS
Synchronization Integrated NetTime network timestamping
Hardware Keying 240 V mechanical coding
Operating Humidity 5 to 95% non-condensing
Country of Origin Austria
Shipping Weight 1.5 kg

Industrial Hardware FAQs

Why does the module feature four current inputs when monitoring a standard three-phase power line?

The first three current inputs map directly to Phases L1, L2, and L3. The fourth auxiliary input is engineered to monitor the neutral conductor (N). In industrial facilities running heavy single-phase switched-mode power supplies or non-linear loads, tracking neutral current is essential to identify harmonic distortions and ground leakage currents.

Can the high-voltage lines up to 480 VAC be wired directly into the standard X20 terminal block?

Yes, but you must ensure that you utilize the correct, officially designated 240 V keyed terminal block matching the X20AP3131 architecture. The mechanical keying ensures that high-voltage distribution wiring cannot be plugged into standard 24 VDC digital or analog I/O slots.

What specific operational value does the NetTime function provide for energy metering?

NetTime synchronizes the module internal ADCs with the central controller system clock down to the microsecond level. This allows the master controller to line up energy consumption surges with precise positions in a high-speed motion control sequence, making it easy to identify exactly which mechanical operation or drive axis is wasting energy.

Field Commissioning and Safety Guidelines

Current Transformer (CT) Interlocking Protocols

When connecting the current inputs, ensure that the external current transformers are properly rated for a 5 A AC secondary output. Never open the secondary circuit of an active current transformer while the primary high-voltage line is energized; doing so will generate extremely high voltage arcs across the CT terminals, destroying the equipment and risking severe electrical shock.

Phase Alignment and Voltage Wiring Rotation

Carefully align the voltage sensing terminal connections (L1, L2, L3) with the corresponding current transformer loops. Mismatching the phase allocation (e.g., pairing the L1 voltage line with the L2 current transformer) will skew the internal vector math, resulting in incorrect calculation of effective power factor metrics.

Grounding and Noise Suppression Standards

Mount the module onto a clean, corrosion-free DIN rail that is bonded directly to the primary structural earth ground of the electrical panel. Keep high-voltage supply lines routed away from low-voltage communication backplanes inside the wire tracking system to prevent electromagnetic coupling from introducing measurement noise into the 16-bit analog processing stages.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Red
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...