B&R

B&R X67AI1223 X67 System 4-Channel Analog Input Module

SKU X67AI1223

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: B&R

  • Product No.: X67AI1223

  • Country of origin:United States

  • Product Type: X67 Analog Input Module

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Dimensions: 4.2cm x 5.3cm x 8.5

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The X67AI1223 (X67AI1223) is a rugged, field-mounted analog input module within the B&R X67 system, specifically designed for decentralized automation without the need for a control cabinet. Featuring four high-precision analog inputs with a voltage range of +/- 10 V, this module is engineered for direct installation on machinery in harsh industrial environments. In sectors such as mobile automation, heavy-duty outdoor equipment, and large-scale manufacturing lines, the X67AI1223 provides critical sensor feedback with minimal wiring overhead. Its IP67-rated protection ensures reliable data acquisition in the presence of dust, moisture, and high mechanical vibration, enabling a truly distributed control architecture that brings I/O processing closer to the physical process.

Technical Configuration

The X67AI1223 architecture is optimized for real-time monitoring, providing four independent channels capable of processing bipolar voltage signals (+/- 10 V). The hardware is equipped with comprehensive status indicators, including dedicated I/O function LEDs for each channel, as well as LEDs for supply voltage and bus communication status. This allows for immediate on-site diagnostics without the need for external software tools. The module utilizes standardized M12 connectors for field signals, ensuring secure, watertight connections. Its compact 53 mm wide housing is designed for direct screw-mounting onto the machine frame, utilizing the X67 bus system for high-speed data transmission and synchronization with the central controller.

Technical Specifications

Feature Specification
Model X67AI1223
Brand B&R (Bernecker + Rainer)
System X67 System (Field-mounted)
Number of Inputs 4 Analog Inputs
Input Range +/- 10 V (Bipolar)
Status Indicators Channel LEDs, Supply Voltage, Bus Function
Protection Rating IP67
Dimensions (W x H x L) 53 mm x 85 mm x 42 mm
Operating Temp -25 to +60 deg C
Weight approx. 0.2 kg
Shipping Weight 1.5 kg

Technical FAQs

Does the X67AI1223 require a separate enclosure?

No. The X67AI1223 is an IP67-rated module designed for cabinet-free installation. It can be mounted directly on the machine or system frame, provided the electrical connections are made with appropriately rated M12 connectors.

What is the benefit of the bipolar +/- 10 V input range?

The bipolar range allows the module to interface with sensors that measure both positive and negative values, such as pressure transducers that measure both vacuum and pressure, or position sensors that determine displacement in two directions from a center zero point.

How do the status indicators assist in troubleshooting?

Each of the 4 channels has an LED that indicates its functional state. If a signal is out of range or a channel fault occurs, the LED provides an immediate visual cue. Combined with the bus and power LEDs, technicians can quickly identify if a problem is related to the sensor, the power supply, or the network communication.

Is this module compatible with POWERLINK?

The X67AI1223 is designed for the X67 system bus. When used with an appropriate X67 bus controller or fieldbus head station, it can be integrated into POWERLINK, CANopen, or other standard industrial Ethernet networks.


Engineering & Installation Guide

  • M12 Connector Integrity: To maintain the IP67 protection rating, ensure that all M12 connectors are tightened to the recommended torque (typically 0.4 Nm to 0.6 Nm). Unused ports must be sealed with professional-grade IP67 protective caps to prevent moisture ingress and internal corrosion.

  • Decentralized Grounding: Since the module is mounted directly to the machine frame, ensure the frame itself is properly bonded to the system ground. Use shielded M12 cables for all +/- 10 V signals, and ensure the cable shield is connected to the M12 connector housing to provide a 360-degree path for electromagnetic interference (EMI).

  • Voltage Supply Stability: The X67AI1223 relies on the X67 bus supply for its internal logic and potentially for sensor power. In long-distance distributed runs, calculate the voltage drop across the bus cables to ensure the supply voltage remains within the specified range for accurate analog-to-digital conversion.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...