Product Description

Description

The BECKHOFF CX1100-0004 is a dedicated power supply and connection module designed to support the CX1010 and CX1020 Embedded PC systems. This module serves as the critical hardware and communication link between the Embedded PC CPU module and the high-performance E-bus (EtherCAT Terminal) I/O system, enabling reliable distributed control architectures.

In addition to distributing 24 V DC power to the system components and connected EtherCAT Terminals, the BECKHOFF CX1100-0004 features integrated non-volatile memory (NOVRAM) for secure, retentive storage of critical system states and variables in the event of a power failure. The integrated, backlit LC display and integrated navigation keys provide essential diagnostic monitoring and status indications directly on the unit.

Features

  • Direct E-bus (EtherCAT Terminal) connection capability
  • Supports E-bus power supply up to 2 A current
  • 8 kbyte integrated NOVRAM for reliable non-volatile data storage
  • Illuminated FSTN liquid crystal display with 2 lines of 16 characters for local diagnostic readouts
  • Integrated 4+1-way navigation switch (Up, Down, Left, Right, Enter) for local user interaction
  • LED status indicators for visual diagnostic verification
  • Compact IP 20 rated design optimized for space-efficient DIN rail mounting

Applications

  • Industrial control and automation systems utilizing CX1010 or CX1020 Embedded PCs
  • Local visualization of machine status parameters and diagnostic alarms without external human-machine interfaces
  • EtherCAT Terminal I/O network connection and power delivery
  • Applications requiring retentive parameter storage for machine state retention

Technical Specifications

General and Environmental
Manufacturer BECKHOFF
Model CX1100-0004
Compatible CPU Modules CX1010, CX1020
Protection Class IP 20
Operating Temperature Range 0 degC to +55 degC
Storage Temperature Range -25 degC to +85 degC
Electrical and Interfaces
Nominal Input Voltage 24 V DC (-15% / +20%)
I/O Connection System E-bus (EtherCAT Terminal adapter)
Max. E-bus Current Supply 2 A
Integrated Non-Volatile Memory 8 kbytes NOVRAM
Display Technology FSTN display, illuminated, 2 lines x 16 characters
Navigation Switch 4+1 keys
Diagnostic Status LEDs 1 x PWR, 1 x L/A, 1 x RUN
Mechanical Dimensions
Width 39 mm
Height 100 mm
Depth 91 mm

Installation Guidelines

  1. Verify that the model number matches the BECKHOFF CX1100-0004 specification label before mounting.
  2. De-energize the entire control cabinet and isolate all voltage sources prior to starting installation or wiring.
  3. Mount the unit securely onto a standard 35 mm DIN rail, ensuring a tight connection with the adjacent Embedded PC module.
  4. Connect the 24 V DC power supply lines to the verified terminal points, paying strict attention to correct voltage polarity.
  5. Ensure that all E-bus connections and terminal end-caps are fully seated and locked in position before applying power.
  6. Restore power to the system and verify that the power LED illuminates, and the LC display initializes correctly.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF CX1100-0004?
The BECKHOFF CX1100-0004 is a dedicated power supply and interface module that provides 24 V DC power to CX1010 and CX1020 Embedded PCs while acting as the physical connection point to an E-bus (EtherCAT Terminal) network.
Does the CX1100-0004 include integrated data storage?
Yes, the BECKHOFF CX1100-0004 contains 8 kbytes of integrated NOVRAM, which provides non-volatile data storage for retentive TwinCAT variables in the event of a power failure.
What kind of diagnostic display is built into the module?
The BECKHOFF CX1100-0004 is equipped with an illuminated, 2-line by 16-character FSTN LC display and an integrated 4+1-way navigation switch for manual configuration and diagnostic status readouts.
What is the maximum current capacity for the E-bus connection?
The BECKHOFF CX1100-0004 supports an E-bus power supply current of up to 2 A for connected EtherCAT Terminal modules.
Reviews

CX1100-0004

Stock & lead time on request

Call
1 of 1

BECKHOFF CX1100-0004 CX Series Power Supply Unit

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX1100-0004

  • Country of origin:Germany

  • Product Type: Power Supply Units

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 1.2 Kg

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF CX1100-0004 is a dedicated power supply and connection module designed to support the CX1010 and CX1020 Embedded PC systems. This module serves as the critical hardware and communication link between the Embedded PC CPU module and the high-performance E-bus (EtherCAT Terminal) I/O system, enabling reliable distributed control architectures.

In addition to distributing 24 V DC power to the system components and connected EtherCAT Terminals, the BECKHOFF CX1100-0004 features integrated non-volatile memory (NOVRAM) for secure, retentive storage of critical system states and variables in the event of a power failure. The integrated, backlit LC display and integrated navigation keys provide essential diagnostic monitoring and status indications directly on the unit.

Features

  • Direct E-bus (EtherCAT Terminal) connection capability
  • Supports E-bus power supply up to 2 A current
  • 8 kbyte integrated NOVRAM for reliable non-volatile data storage
  • Illuminated FSTN liquid crystal display with 2 lines of 16 characters for local diagnostic readouts
  • Integrated 4+1-way navigation switch (Up, Down, Left, Right, Enter) for local user interaction
  • LED status indicators for visual diagnostic verification
  • Compact IP 20 rated design optimized for space-efficient DIN rail mounting

Applications

  • Industrial control and automation systems utilizing CX1010 or CX1020 Embedded PCs
  • Local visualization of machine status parameters and diagnostic alarms without external human-machine interfaces
  • EtherCAT Terminal I/O network connection and power delivery
  • Applications requiring retentive parameter storage for machine state retention

Technical Specifications

General and Environmental
Manufacturer BECKHOFF
Model CX1100-0004
Compatible CPU Modules CX1010, CX1020
Protection Class IP 20
Operating Temperature Range 0 degC to +55 degC
Storage Temperature Range -25 degC to +85 degC
Electrical and Interfaces
Nominal Input Voltage 24 V DC (-15% / +20%)
I/O Connection System E-bus (EtherCAT Terminal adapter)
Max. E-bus Current Supply 2 A
Integrated Non-Volatile Memory 8 kbytes NOVRAM
Display Technology FSTN display, illuminated, 2 lines x 16 characters
Navigation Switch 4+1 keys
Diagnostic Status LEDs 1 x PWR, 1 x L/A, 1 x RUN
Mechanical Dimensions
Width 39 mm
Height 100 mm
Depth 91 mm

Installation Guidelines

  1. Verify that the model number matches the BECKHOFF CX1100-0004 specification label before mounting.
  2. De-energize the entire control cabinet and isolate all voltage sources prior to starting installation or wiring.
  3. Mount the unit securely onto a standard 35 mm DIN rail, ensuring a tight connection with the adjacent Embedded PC module.
  4. Connect the 24 V DC power supply lines to the verified terminal points, paying strict attention to correct voltage polarity.
  5. Ensure that all E-bus connections and terminal end-caps are fully seated and locked in position before applying power.
  6. Restore power to the system and verify that the power LED illuminates, and the LC display initializes correctly.
Loading product navigation…

What is the primary function of the BECKHOFF CX1100-0004?

The BECKHOFF CX1100-0004 is a dedicated power supply and interface module that provides 24 V DC power to CX1010 and CX1020 Embedded PCs while acting as the physical connection point to an E-bus (EtherCAT Terminal) network.

Does the CX1100-0004 include integrated data storage?

Yes, the BECKHOFF CX1100-0004 contains 8 kbytes of integrated NOVRAM, which provides non-volatile data storage for retentive TwinCAT variables in the event of a power failure.

What kind of diagnostic display is built into the module?

The BECKHOFF CX1100-0004 is equipped with an illuminated, 2-line by 16-character FSTN LC display and an integrated 4+1-way navigation switch for manual configuration and diagnostic status readouts.

What is the maximum current capacity for the E-bus connection?

The BECKHOFF CX1100-0004 supports an E-bus power supply current of up to 2 A for connected EtherCAT Terminal modules.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...