Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
The BECKHOFF EP9224-0037 is an IP67-rated EtherCAT Box designed for robust power distribution, branching, and diagnostics within EtherCAT P networks. It serves as an active EtherCAT P junction, enabling the safe feed-in, loop-through, and branch routing of Us (system and sensor power) and Up (peripheral voltage for actuators). By utilizing robust B17 ENP connectors with a secure bayonet fitting, this module distributes incoming power to downstream devices while continuously monitoring the electrical parameters of each branch.
Integrated measurement circuitry in the BECKHOFF EP9224-0037 tracks the input voltages, input currents, and individual output currents for all channels. This diagnostic information is transmitted directly via process data to the master controller, allowing for rapid overload detection and localized isolation. In the event of a system fault or power failure, internal data logging capabilities record relevant diagnostic data to simplify troubleshooting and maintenance workflows.
| Manufacturer | BECKHOFF |
| Exact Model | EP9224-0037 |
| Product Type | EtherCAT P Junction and Power Distributor |
| Protocol | EtherCAT |
| Number of Channels | 1 x ENP IN, 1 x ENP OUT (Feedthrough), 4 x EtherCAT P OUT |
| Infeed Connector | ENP B17, 5-pin |
| Maximum Infeed Current | 15.5 A per Us / Up at 45 degC |
| Power Feedthrough Connector | ENP B17, 5-pin |
| Maximum Feedthrough Current | 15.5 A per Us / Up at 45 degC |
| Current Rating per Output Port | Max. 3.0 A per Us and Up (M8 P-coded) |
| Diagnostic Features | Input voltages/currents, individual output currents via process data |
| Data Logging | Failure-related status recording |
| Bus Interface | 2 x B17 ENP, shielded, bayonet fitting |
| IP Protection Class | IP67 |
| Operating Temperature | -25 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Vibration Resistance | Conforms to EN 60068-2-6 |
| Shock Resistance | Conforms to EN 60068-2-27 |
| EMC Immunity and Emission | Conforms to EN 61000-6-2 and EN 61000-6-4 |
| Approvals and Markings | CE |
| Interface / Connector | Function |
|---|---|
| ENP IN (B17, 5-pin) | Power infeed (Us / Up) and incoming EtherCAT communication link |
| ENP OUT (B17, 5-pin) | High-current power feedthrough loop and outgoing EtherCAT communication link |
| EtherCAT P OUT 1 to 4 (M8, P-coded) | Distributed EtherCAT P outputs with independent monitoring (Max. 3.0 A per port) |
When replacing a BECKHOFF EP9224-0037 module, document and label all connected M8 and B17 cabling before removal to prevent mismating during reinstallation. Ensure that downstream load profiles do not exceed the 3.0 A per-port limit or the aggregate 15.5 A limit on the replacement unit. Verify that the correct hardware revision and configuration profiles are active in your TwinCAT system manager after mounting the replacement unit.
Global Express Shipping
Returns & Warranty

The BECKHOFF EP9224-0037 is an IP67-rated EtherCAT Box designed for robust power distribution, branching, and diagnostics within EtherCAT P networks. It serves as an active EtherCAT P junction, enabling the safe feed-in, loop-through, and branch routing of Us (system and sensor power) and Up (peripheral voltage for actuators). By utilizing robust B17 ENP connectors with a secure bayonet fitting, this module distributes incoming power to downstream devices while continuously monitoring the electrical parameters of each branch.
Integrated measurement circuitry in the BECKHOFF EP9224-0037 tracks the input voltages, input currents, and individual output currents for all channels. This diagnostic information is transmitted directly via process data to the master controller, allowing for rapid overload detection and localized isolation. In the event of a system fault or power failure, internal data logging capabilities record relevant diagnostic data to simplify troubleshooting and maintenance workflows.
| Manufacturer | BECKHOFF |
| Exact Model | EP9224-0037 |
| Product Type | EtherCAT P Junction and Power Distributor |
| Protocol | EtherCAT |
| Number of Channels | 1 x ENP IN, 1 x ENP OUT (Feedthrough), 4 x EtherCAT P OUT |
| Infeed Connector | ENP B17, 5-pin |
| Maximum Infeed Current | 15.5 A per Us / Up at 45 degC |
| Power Feedthrough Connector | ENP B17, 5-pin |
| Maximum Feedthrough Current | 15.5 A per Us / Up at 45 degC |
| Current Rating per Output Port | Max. 3.0 A per Us and Up (M8 P-coded) |
| Diagnostic Features | Input voltages/currents, individual output currents via process data |
| Data Logging | Failure-related status recording |
| Bus Interface | 2 x B17 ENP, shielded, bayonet fitting |
| IP Protection Class | IP67 |
| Operating Temperature | -25 to +60 degC |
| Storage Temperature | -40 to +85 degC |
| Vibration Resistance | Conforms to EN 60068-2-6 |
| Shock Resistance | Conforms to EN 60068-2-27 |
| EMC Immunity and Emission | Conforms to EN 61000-6-2 and EN 61000-6-4 |
| Approvals and Markings | CE |
| Interface / Connector | Function |
|---|---|
| ENP IN (B17, 5-pin) | Power infeed (Us / Up) and incoming EtherCAT communication link |
| ENP OUT (B17, 5-pin) | High-current power feedthrough loop and outgoing EtherCAT communication link |
| EtherCAT P OUT 1 to 4 (M8, P-coded) | Distributed EtherCAT P outputs with independent monitoring (Max. 3.0 A per port) |
When replacing a BECKHOFF EP9224-0037 module, document and label all connected M8 and B17 cabling before removal to prevent mismating during reinstallation. Ensure that downstream load profiles do not exceed the 3.0 A per-port limit or the aggregate 15.5 A limit on the replacement unit. Verify that the correct hardware revision and configuration profiles are active in your TwinCAT system manager after mounting the replacement unit.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Germany
|