BECKHOFF

BECKHOFF EP9224-0037 EtherCAT Box Power Distributor

SKU EP9224-0037

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EP9224-0037
  • Origin Germany
  • Product Type: EtherCAT Box Modules
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF EP9224-0037 is an IP67-rated EtherCAT Box designed for robust power distribution, branching, and diagnostics within EtherCAT P networks. It serves as an active EtherCAT P junction, enabling the safe feed-in, loop-through, and branch routing of Us (system and sensor power) and Up (peripheral voltage for actuators). By utilizing robust B17 ENP connectors with a secure bayonet fitting, this module distributes incoming power to downstream devices while continuously monitoring the electrical parameters of each branch.

Integrated measurement circuitry in the BECKHOFF EP9224-0037 tracks the input voltages, input currents, and individual output currents for all channels. This diagnostic information is transmitted directly via process data to the master controller, allowing for rapid overload detection and localized isolation. In the event of a system fault or power failure, internal data logging capabilities record relevant diagnostic data to simplify troubleshooting and maintenance workflows.

Features

  • Active EtherCAT P power distribution and topology junction.
  • B17 ENP shielded connections featuring a secure bayonet fitting.
  • One ENP B17 input, one ENP B17 feedthrough, and four M8 P-coded EtherCAT P output channels.
  • Continuous voltage and current monitoring for Us and Up paths.
  • Internal data logging functionality for capturing event data during electrical failures.
  • Real-time diagnostic feedback transmitted directly through standard process data.
  • IP67-rated enclosure suitable for cabinet-free field installations in demanding environments.

Applications

  • Decentralized power routing and branch topology creation in modular machinery.
  • Fieldbus system distribution requiring high-current power transmission and localized diagnostic feedback.
  • Star-topology configuration adjustments within complex EtherCAT P industrial networks.
  • Cabinet-free machine setups requiring IP67 protection against liquids and dust.

Technical Specifications

General

Manufacturer BECKHOFF
Exact Model EP9224-0037
Product Type EtherCAT P Junction and Power Distributor
Protocol EtherCAT
Number of Channels 1 x ENP IN, 1 x ENP OUT (Feedthrough), 4 x EtherCAT P OUT

Electrical Data

Infeed Connector ENP B17, 5-pin
Maximum Infeed Current 15.5 A per Us / Up at 45 degC
Power Feedthrough Connector ENP B17, 5-pin
Maximum Feedthrough Current 15.5 A per Us / Up at 45 degC
Current Rating per Output Port Max. 3.0 A per Us and Up (M8 P-coded)
Diagnostic Features Input voltages/currents, individual output currents via process data
Data Logging Failure-related status recording

Physical and Environmental

Bus Interface 2 x B17 ENP, shielded, bayonet fitting
IP Protection Class IP67
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals and Markings CE

Connections / Interfaces

Interface / Connector Function
ENP IN (B17, 5-pin) Power infeed (Us / Up) and incoming EtherCAT communication link
ENP OUT (B17, 5-pin) High-current power feedthrough loop and outgoing EtherCAT communication link
EtherCAT P OUT 1 to 4 (M8, P-coded) Distributed EtherCAT P outputs with independent monitoring (Max. 3.0 A per port)

Installation Guidelines

  1. Ensure the supply power to all feed cables is fully de-energized before beginning installation.
  2. Verify that the physical mounting location is clean, flat, and allows appropriate cable bend radiuses for the B17 and M8 connectors.
  3. Securely mount the module using the integrated mounting holes on the outer casing.
  4. Connect the incoming B17 ENP power and communication cable to the ENP IN port. Tighten the bayonet coupling fully to ensure an IP67 seal.
  5. Connect the feedthrough or branched M8 P-coded cables to the respective downstream devices. Ensure unused ports are fitted with appropriate IP67 protection caps.
  6. Establish continuous grounding and shield connections across all connected interfaces.
  7. Energize the system and verify the status LEDs illuminate, indicating correct bus communication and power distribution states.

Replacement Recommendations

When replacing a BECKHOFF EP9224-0037 module, document and label all connected M8 and B17 cabling before removal to prevent mismating during reinstallation. Ensure that downstream load profiles do not exceed the 3.0 A per-port limit or the aggregate 15.5 A limit on the replacement unit. Verify that the correct hardware revision and configuration profiles are active in your TwinCAT system manager after mounting the replacement unit.

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF EP9224-0037?
The BECKHOFF EP9224-0037 acts as an active EtherCAT P junction and power distributor, allowing the feed-in, looping, and branching of Us (system and sensor voltage) and Up (peripheral voltage for actuators) within industrial networks.
What are the maximum current capacities of the BECKHOFF EP9224-0037 connections?
The BECKHOFF EP9224-0037 supports a maximum infeed and power feedthrough current of 15.5 A per Us and Up via its B17 ENP connections at 45 degrees Celsius, while individual M8 P-coded branch ports are rated for up to 3.0 A per channel.
Does the BECKHOFF EP9224-0037 provide channel-level diagnostics?
Yes, the BECKHOFF EP9224-0037 continuously monitors incoming and outgoing voltages and currents, transmitting diagnostic status directly to the controller via EtherCAT process data.
Can the BECKHOFF EP9224-0037 be mounted outside of a control cabinet?
Yes, the BECKHOFF EP9224-0037 features a robust IP67-rated enclosure, making it fully suitable for direct machine mounting in environments exposed to moisture, dust, and mechanical vibrations.
What connector types are utilized on the BECKHOFF EP9224-0037?
The BECKHOFF EP9224-0037 uses 5-pin B17 ENP shielded connectors with bayonet fittings for incoming and loop-through power, alongside four standard M8 P-coded female connectors for its EtherCAT P branch outputs.
Reviews

EP9224-0037

Stock & lead time on request

Call
1 of 1

BECKHOFF EP9224-0037 EtherCAT Box Power Distributor

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP9224-0037

  • Country of origin:Germany

  • Product Type: EtherCAT Box Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The BECKHOFF EP9224-0037 is an IP67-rated EtherCAT Box designed for robust power distribution, branching, and diagnostics within EtherCAT P networks. It serves as an active EtherCAT P junction, enabling the safe feed-in, loop-through, and branch routing of Us (system and sensor power) and Up (peripheral voltage for actuators). By utilizing robust B17 ENP connectors with a secure bayonet fitting, this module distributes incoming power to downstream devices while continuously monitoring the electrical parameters of each branch.

Integrated measurement circuitry in the BECKHOFF EP9224-0037 tracks the input voltages, input currents, and individual output currents for all channels. This diagnostic information is transmitted directly via process data to the master controller, allowing for rapid overload detection and localized isolation. In the event of a system fault or power failure, internal data logging capabilities record relevant diagnostic data to simplify troubleshooting and maintenance workflows.

Features

  • Active EtherCAT P power distribution and topology junction.
  • B17 ENP shielded connections featuring a secure bayonet fitting.
  • One ENP B17 input, one ENP B17 feedthrough, and four M8 P-coded EtherCAT P output channels.
  • Continuous voltage and current monitoring for Us and Up paths.
  • Internal data logging functionality for capturing event data during electrical failures.
  • Real-time diagnostic feedback transmitted directly through standard process data.
  • IP67-rated enclosure suitable for cabinet-free field installations in demanding environments.

Applications

  • Decentralized power routing and branch topology creation in modular machinery.
  • Fieldbus system distribution requiring high-current power transmission and localized diagnostic feedback.
  • Star-topology configuration adjustments within complex EtherCAT P industrial networks.
  • Cabinet-free machine setups requiring IP67 protection against liquids and dust.

Technical Specifications

General

Manufacturer BECKHOFF
Exact Model EP9224-0037
Product Type EtherCAT P Junction and Power Distributor
Protocol EtherCAT
Number of Channels 1 x ENP IN, 1 x ENP OUT (Feedthrough), 4 x EtherCAT P OUT

Electrical Data

Infeed Connector ENP B17, 5-pin
Maximum Infeed Current 15.5 A per Us / Up at 45 degC
Power Feedthrough Connector ENP B17, 5-pin
Maximum Feedthrough Current 15.5 A per Us / Up at 45 degC
Current Rating per Output Port Max. 3.0 A per Us and Up (M8 P-coded)
Diagnostic Features Input voltages/currents, individual output currents via process data
Data Logging Failure-related status recording

Physical and Environmental

Bus Interface 2 x B17 ENP, shielded, bayonet fitting
IP Protection Class IP67
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity and Emission Conforms to EN 61000-6-2 and EN 61000-6-4
Approvals and Markings CE

Connections / Interfaces

Interface / Connector Function
ENP IN (B17, 5-pin) Power infeed (Us / Up) and incoming EtherCAT communication link
ENP OUT (B17, 5-pin) High-current power feedthrough loop and outgoing EtherCAT communication link
EtherCAT P OUT 1 to 4 (M8, P-coded) Distributed EtherCAT P outputs with independent monitoring (Max. 3.0 A per port)

Installation Guidelines

  1. Ensure the supply power to all feed cables is fully de-energized before beginning installation.
  2. Verify that the physical mounting location is clean, flat, and allows appropriate cable bend radiuses for the B17 and M8 connectors.
  3. Securely mount the module using the integrated mounting holes on the outer casing.
  4. Connect the incoming B17 ENP power and communication cable to the ENP IN port. Tighten the bayonet coupling fully to ensure an IP67 seal.
  5. Connect the feedthrough or branched M8 P-coded cables to the respective downstream devices. Ensure unused ports are fitted with appropriate IP67 protection caps.
  6. Establish continuous grounding and shield connections across all connected interfaces.
  7. Energize the system and verify the status LEDs illuminate, indicating correct bus communication and power distribution states.

Replacement Recommendations

When replacing a BECKHOFF EP9224-0037 module, document and label all connected M8 and B17 cabling before removal to prevent mismating during reinstallation. Ensure that downstream load profiles do not exceed the 3.0 A per-port limit or the aggregate 15.5 A limit on the replacement unit. Verify that the correct hardware revision and configuration profiles are active in your TwinCAT system manager after mounting the replacement unit.

Loading product navigation…

What is the primary function of the BECKHOFF EP9224-0037?

The BECKHOFF EP9224-0037 acts as an active EtherCAT P junction and power distributor, allowing the feed-in, looping, and branching of Us (system and sensor voltage) and Up (peripheral voltage for actuators) within industrial networks.

What are the maximum current capacities of the BECKHOFF EP9224-0037 connections?

The BECKHOFF EP9224-0037 supports a maximum infeed and power feedthrough current of 15.5 A per Us and Up via its B17 ENP connections at 45 degrees Celsius, while individual M8 P-coded branch ports are rated for up to 3.0 A per channel.

Does the BECKHOFF EP9224-0037 provide channel-level diagnostics?

Yes, the BECKHOFF EP9224-0037 continuously monitors incoming and outgoing voltages and currents, transmitting diagnostic status directly to the controller via EtherCAT process data.

Can the BECKHOFF EP9224-0037 be mounted outside of a control cabinet?

Yes, the BECKHOFF EP9224-0037 features a robust IP67-rated enclosure, making it fully suitable for direct machine mounting in environments exposed to moisture, dust, and mechanical vibrations.

What connector types are utilized on the BECKHOFF EP9224-0037?

The BECKHOFF EP9224-0037 uses 5-pin B17 ENP shielded connectors with bayonet fittings for incoming and loop-through power, alongside four standard M8 P-coded female connectors for its EtherCAT P branch outputs.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.