BECKHOFF

BECKHOFF ERI1008-0001 IO-Link Box 8-Channel Digital Input

SKU ERI1008-0001

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: ERI1008-0001

  • Country of origin:Germany

  • Product Type: IO-Link Modules

  • Payment: T/T, Western Union

  • Weight: 265g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF ERI1008-0001 is an industrial-grade IO-Link box designed for direct field-level acquisition of digital signals without a control cabinet. Operating as an IO-Link device, this module transmits eight digital input signals from the field to an IO-Link master. Its design allows for decentralized installation, minimizing wiring runs and simplifying field integration in modern automation topologies.

Equipped with durable, screw-type M8 connection points for inputs and a single, A-coded M12 plug for the IO-Link interface, the BECKHOFF ERI1008-0001 ensures reliable electrical connections under constant mechanical vibration. It complies with the IO-Link V1.1 specification (Class A) and operates at the high-speed COM 3 transmission rate to deliver quick, reliable input state updates to the controller.

The module features Type 3 digital inputs conforming to EN 61131-2, ensuring high compatibility with standard proximity sensors and switches. Integrated protection features include short-circuit proof sensor supply and configurable input filter times to optimize signal integrity in electrically noisy environments.

Features

  • Eight independent digital input channels with Type 3 signal characteristics.
  • High-speed IO-Link communication (Class A) supporting data transfer rates up to 230.4 kbaud (COM 3).
  • Durable M8 screw-type connection points for secure sensor wiring.
  • Configurable input filter times from 0 to 20 ms to prevent contact bounce and signal noise.
  • Integrated sensor supply rated up to 0.5 A from the L+ line with complete short-circuit protection.
  • Heavy-duty ingress protection (IP65, IP66, and IP67) for installation in harsh, washdown, or dusty environments.

Applications

  • Decentralized input aggregation on robotic arms, gantry systems, and conveyor lines.
  • Machine-mount sensor wiring where cabinet space is unavailable or limited.
  • High-speed assembly and packaging machinery demanding low-latency digital signal processing.
  • Standardized connection of standard industrial sensors to IO-Link fieldbus systems.

Technical Specifications

General Specifications

Manufacturer BECKHOFF
Exact Model ERI1008-0001
Product Type IO-Link Box
Weight approx. 265 g

IO-Link and Communication

Protocol IO-Link
Specification Version IO-Link V1.1, Class A
Data Transfer Rates 230.4 kbaud (COM 3)
Interface Connection 1 x M12 plug, A-coded
Current Consumption typ. 100 mA from L+

Digital Inputs

Number of Inputs 8
Input Connection Type M8, screw type
Nominal Input Voltage 24 V DC (-15% / +20%)
Input Filter Time 3.0 ms (default), adjustable 0 to 20 ms
"0" Signal Voltage -3 to +5 V (EN 61131-2, type 3)
"1" Signal Voltage 11 to 30 V (EN 61131-2, type 3)
Input Current typ. 3 mA (EN 61131-2, type 3)
Sensor Supply max. 0.5 A (from L+), short-circuit proof in total

Environmental and Standards

Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals / Markings CE, UL

Connections / Interfaces

Interface / Port Function
M12 Connector (A-coded) IO-Link upstream connection to master (Class A) and power supply
M8 Ports (Channels 1–8) Physical connections for the 8 digital input signals and sensor power

Installation Guidelines

  1. Verify Equipment: Ensure that the model number matches ERI1008-0001 and inspect the housing and connectors for physical integrity before mounting.
  2. Power De-energization: Isolate all electrical supply lines, including the IO-Link master feed, prior to performing installation or wiring procedures.
  3. Mechanical Mounting: Fasten the IO-Link box to a stable mounting surface using appropriate screws. The installation position is variable, but must prevent strain on connected cables.
  4. IO-Link Connection: Connect the A-coded M12 cable from the IO-Link master to the designated M12 port on the module. Hand-tighten the coupling ring to secure the ingress protection seal.
  5. Sensor Wiring: Connect the digital sensors to the M8 screw-type input ports. Ensure connectors are securely threaded to maintain the IP67 protection rating.
  6. System Commissioning: Apply supply voltage to the system. Configure the IO-Link master to recognize the device, setting the appropriate input filter times within the 0 to 20 ms range as dictated by your application.

FAQ

What is the primary communication interface and transfer rate of the BECKHOFF ERI1008-0001?

The BECKHOFF ERI1008-0001 uses an IO-Link V1.1 (Class A) interface and communicates at a high-speed data transfer rate of 230.4 kbaud (COM 3) via a single A-coded M12 plug.

What connector types are used for the sensor inputs on the BECKHOFF ERI1008-0001?

The BECKHOFF ERI1008-0001 is equipped with 8 digital input channels accessible via screw-type M8 connectors.

Can the BECKHOFF ERI1008-0001 be mounted directly on a machine without an electrical cabinet?

Yes, the BECKHOFF ERI1008-0001 features an IP65, IP66, and IP67 protection rating, making it suitable for decentralized installation directly on machinery without requiring a control cabinet.

Does the BECKHOFF ERI1008-0001 provide power to the connected sensors?

Yes, the BECKHOFF ERI1008-0001 provides a short-circuit-proof sensor supply with a maximum combined current limit of 0.5 A drawn from the L+ line.

Are the input filters configurable on the BECKHOFF ERI1008-0001?

Yes, the BECKHOFF ERI1008-0001 features adjustable input filter times from 0 to 20 ms, with a default factory setting of 3.0 ms to help eliminate contact bounce and electromagnetic noise.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.