Description

The BECKHOFF IP1001-B310 is a decentralized Fieldbus Box designed to acquisition digital input signals directly in the field, bypassing the need for an industrial control cabinet. Engineered for direct machine mounting, this high-durability module connects up to eight digital sensors to a master controller via a PROFIBUS DP interface.

This module features space-saving M8 connection technology for standard sensors alongside robust power distribution and diagnostic capabilities. By placing the I/O interface directly on the equipment, the module reduces wiring overhead and installation complexity in industrial automation systems.

Features

  • Eight digital input channels for 24 V DC sensor signals.
  • Integrated PROFIBUS DP interface supporting automatic baud rate detection.
  • Decentralized IP67 protection rating for enclosure-free field deployment.
  • Input signal filtering of 3 ms to prevent signal bounce and transient errors.
  • M8 connectors for compact, reliable sensor signal connections.
  • M12 fieldbus interface for secure industrial communication.
  • Power routing via dedicated M8 input feed and downstream loop-through connections.

Applications

  • Cabinet-free machine architecture and decentralized automation setups.
  • Material handling, logistics, and conveyor lines.
  • Packaging, assembly, and industrial production plants.
  • Distributed sensor networks operating under standard PROFIBUS DP protocols.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1001-B310
Product Type Fieldbus Box

Signal and I/O

Parameter Specification
Number of Inputs 8 digital inputs
Nominal Input Voltage 24 V DC
Input Filter Time 3 ms
Connection Technology M8 screw-type

Fieldbus and Communication

Parameter Specification
Protocol PROFIBUS DP (DP-V1 supported)
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Interface 1 x M12 socket, 5-pin, B-coded
Configuration Options Via KS2000 software or master controller

Electrical

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)

Mechanical and Environmental

Parameter Specification
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure all electrical supplies are fully de-energized and locked out before starting installation.
  2. Secure the module to the machine frame using appropriate mounting holes on the housing.
  3. Connect the PROFIBUS DP network cable to the B-coded M12 fieldbus socket.
  4. Connect the 24 V DC control voltage to the M8 male feed socket. If linking multiple modules, connect the downstream M8 cable to the next device.
  5. Plug the 24 V DC sensors into the 8 x M8 input sockets, making sure all connections are securely tightened to maintain the IP67 environmental seal.
  6. Apply power and inspect the integrated status LEDs for correct network and device diagnosis.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP1001-B310?
The BECKHOFF IP1001-B310 is a decentralized Fieldbus Box designed to receive up to 8 digital input signals from 24 V DC sensors and transmit them over a PROFIBUS DP network.
What connector types are used on the BECKHOFF IP1001-B310?
The BECKHOFF IP1001-B310 uses compact M8 connectors for its 8 digital inputs, a B-coded M12 interface for the PROFIBUS DP line, and M8 connectors for power supply feed and downstream routing.
Does the BECKHOFF IP1001-B310 require an IP-rated enclosure?
No, the BECKHOFF IP1001-B310 has a built-in IP67 environmental rating, allowing direct machine mounting in wet, dusty, or harsh industrial environments without a separate control enclosure.
What is the input signal filter time of the BECKHOFF IP1001-B310?
The BECKHOFF IP1001-B310 has a hardware input filter time of 3 ms to ensure stable, reliable digital signal readings.
Reviews

IP1001-B310

Stock & lead time on request

Call
1 of 1

BECKHOFF IP1001-B310 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP1001-B310

  • Country of origin:Germany

  • Product Type: Fieldbus Boxes

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF IP1001-B310 is a decentralized Fieldbus Box designed to acquisition digital input signals directly in the field, bypassing the need for an industrial control cabinet. Engineered for direct machine mounting, this high-durability module connects up to eight digital sensors to a master controller via a PROFIBUS DP interface.

This module features space-saving M8 connection technology for standard sensors alongside robust power distribution and diagnostic capabilities. By placing the I/O interface directly on the equipment, the module reduces wiring overhead and installation complexity in industrial automation systems.

Features

  • Eight digital input channels for 24 V DC sensor signals.
  • Integrated PROFIBUS DP interface supporting automatic baud rate detection.
  • Decentralized IP67 protection rating for enclosure-free field deployment.
  • Input signal filtering of 3 ms to prevent signal bounce and transient errors.
  • M8 connectors for compact, reliable sensor signal connections.
  • M12 fieldbus interface for secure industrial communication.
  • Power routing via dedicated M8 input feed and downstream loop-through connections.

Applications

  • Cabinet-free machine architecture and decentralized automation setups.
  • Material handling, logistics, and conveyor lines.
  • Packaging, assembly, and industrial production plants.
  • Distributed sensor networks operating under standard PROFIBUS DP protocols.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Model IP1001-B310
Product Type Fieldbus Box

Signal and I/O

Parameter Specification
Number of Inputs 8 digital inputs
Nominal Input Voltage 24 V DC
Input Filter Time 3 ms
Connection Technology M8 screw-type

Fieldbus and Communication

Parameter Specification
Protocol PROFIBUS DP (DP-V1 supported)
Data Transfer Rates Automatic detection up to 12 Mbaud
Bus Interface 1 x M12 socket, 5-pin, B-coded
Configuration Options Via KS2000 software or master controller

Electrical

Parameter Specification
Control Voltage 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Box Supply Current 85 mA + sensor current consumption (max. 0.5 A)

Mechanical and Environmental

Parameter Specification
Protection Class IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Installation Guidelines

  1. Ensure all electrical supplies are fully de-energized and locked out before starting installation.
  2. Secure the module to the machine frame using appropriate mounting holes on the housing.
  3. Connect the PROFIBUS DP network cable to the B-coded M12 fieldbus socket.
  4. Connect the 24 V DC control voltage to the M8 male feed socket. If linking multiple modules, connect the downstream M8 cable to the next device.
  5. Plug the 24 V DC sensors into the 8 x M8 input sockets, making sure all connections are securely tightened to maintain the IP67 environmental seal.
  6. Apply power and inspect the integrated status LEDs for correct network and device diagnosis.
Loading product navigation…
Key Features:

What is the primary function of the BECKHOFF IP1001-B310?

The BECKHOFF IP1001-B310 is a decentralized Fieldbus Box designed to receive up to 8 digital input signals from 24 V DC sensors and transmit them over a PROFIBUS DP network.

What connector types are used on the BECKHOFF IP1001-B310?

The BECKHOFF IP1001-B310 uses compact M8 connectors for its 8 digital inputs, a B-coded M12 interface for the PROFIBUS DP line, and M8 connectors for power supply feed and downstream routing.

Does the BECKHOFF IP1001-B310 require an IP-rated enclosure?

No, the BECKHOFF IP1001-B310 has a built-in IP67 environmental rating, allowing direct machine mounting in wet, dusty, or harsh industrial environments without a separate control enclosure.

What is the input signal filter time of the BECKHOFF IP1001-B310?

The BECKHOFF IP1001-B310 has a hardware input filter time of 3 ms to ensure stable, reliable digital signal readings.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...