Description
The BECKHOFF IP2020-B800 is a decentralized digital output module belonging to the Fieldbus Box product family. Designed for machine-level mounting without control cabinets, this unit provides industrial automation systems with distributed switching capabilities directly in the harsh plant environment.
Equipped with 8 digital outputs, the IP2020-B800 connects directly to an open, documented fieldbus system via an M12 socket interface. The device features an IP65/IP66/IP67 protection rating, making it suitable for direct installation on machine frames where dust, moisture, and mechanical stress are present.
Features
- Decentralized digital output module with 8 channels
- Rugged IP65/IP66/IP67 housing for cabinet-free machine mounting
- Fieldbus connection via M12 socket (5-pin, B-coded)
- Outputs capable of handling ohmic, inductive, and lamp loads
- Individual short-circuit protection per channel
- M8 connector technology for power supply feed and downstream connection
Applications
- Decentralized machine control and automation architectures
- Automated material handling and conveyor systems
- Packaging and sorting machinery
- Assembly lines requiring cabinet-free I/O distribution
Technical Specifications
General
| Parameter |
Specification |
| Manufacturer |
BECKHOFF |
| Exact Model |
IP2020-B800 |
| Product Type |
Fieldbus Box |
| Material |
PA6 (polyamide) |
| Net Weight |
approx. 210 g |
| Dimensions (W x H x D) |
30 mm x 175 mm x 26.5 mm |
Digital Outputs
| Parameter |
Specification |
| Number of Outputs |
8 |
| Output Connections |
8 mm, snap type |
| Load Type |
Ohmic, inductive, lamp load |
| Nominal Output Voltage |
24 V DC (-15 % / +20 %) |
| Max. Output Current |
2 A per channel (individually short-circuit proof, sum max. 4 A) |
| Short-Circuit Current |
max. 4 A |
| Bit Width in Process Image |
8 outputs |
Power Supply and Communication
| Parameter |
Specification |
| Control Voltage Supply |
24 V DC (-15 % / +20 %) |
| Power Supply Connection |
Feed: 1 x M8 male socket, 4-pin; Downstream: 1 x M8 female socket, 4-pin |
| Box Supply Current |
45 mA + current consumption of sensors, max. 0.5 A |
| Bus Interface |
1 x M12 socket, 5-pin, B-coded |
| Protocol |
Open, documented protocol |
| Configuration |
Via KS2000 |
Environment and Compliance
| Parameter |
Specification |
| Protection Rating |
IP65/IP66/IP67 (conforms to EN 60529) |
| Operating Temperature |
0 to +55 degC |
| Storage Temperature |
-25 to +85 degC |
| Vibration/Shock Resistance |
Conforms to EN 60068-2-6 / EN 60068-2-27 |
| EMC Immunity/Emission |
Conforms to EN 61000-6-2 / EN 61000-6-4 |
| Approvals/Markings |
CE, UL |
Installation Guidelines
- Ensure the system is completely de-energized before beginning mechanical installation or wiring.
- Mount the IP2020-B800 securely onto a flat machine surface using the two 3.5 mm fixing holes designated for M3 screws in any desired installation position.
- Connect the 24 V DC control voltage supply to the M8 male feed socket, utilizing downstream M8 female sockets if daisy-chaining power to additional modules.
- Connect the fieldbus line to the M12 B-coded socket using appropriate shielded cables.
- Attach actuators and loads to the 8 mm snap-type output connections, verifying that individual and total current limits are respected.
- Verify all connections and potential supplies before restoring power and commissioning the station via the control system.