Description
The BECKHOFF IP3102-B310 is a high-performance Fieldbus Box designed to bridge analog inputs directly to a PROFIBUS DP network. Developed for decentralized automation architectures, this module enables direct sensor connection in the field without the need for a protective control cabinet. By utilizing standardized industrial connections, it facilitates rapid installation, minimizes wiring complexity, and reduces system footprint.
Operating as a PROFIBUS DP slave, the BECKHOFF IP3102-B310 supports automatic baud rate detection up to 12 Mbaud, ensuring integration into existing communication networks. Its design features an IP67-rated enclosure, providing protection against dust, water, and mechanical stress in demanding industrial environments.
Features
- Direct integration with PROFIBUS DP networks supporting DP-V1 extensions.
- Automatic fieldbus baud rate detection up to 12 Mbaud.
- Industrial M12 fieldbus connection technology with B-coding.
- M8 power supply connections with loop-through capability for downstream modules.
- Flexible parameter configuration via the BECKHOFF KS2000 software or directly through the fieldbus controller.
- High-density IP65, IP66, and IP67 protection class for decentralized, cabinet-free mounting.
Applications
- Decentralized data acquisition and analog sensor integration.
- Cabinet-free machine-mount installation in assembly lines and conveyor systems.
- Process monitoring and field-level signal processing in harsh industrial environments.
Technical Specifications
General
| Manufacturer |
BECKHOFF |
| Exact Model |
IP3102-B310 |
| Product Type |
Fieldbus Box (Analog Input) |
| Configuration Option |
Via KS2000 configuration software or the controller |
Electrical
| Control Voltage Supply |
24 V DC (-15% / +20%) |
| Load Voltage Supply |
Dependent on I/O type |
| Box Supply Current |
85 mA + sensor current consumption (max. 0.5 A) |
| Power Supply Connection |
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin) |
| Electrical Isolation |
Control voltage/fieldbus: No; Control voltage/inputs: Dependent on I/O type |
Fieldbus and Communication
| Fieldbus Protocol |
PROFIBUS DP (supports DP-V1 extensions) |
| Data Transfer Rates |
Automatic detection up to 12 Mbaud |
| Bus Interface Connection |
1 x M12 socket, 5-pin, B-coded |
| Data Transfer Medium |
Shielded copper cable, 2 x 0.25 mm² |
| Data Transfer Time |
Approximately 0.5 ms with 10 stations (each with 32-bit input and output) |
Mechanical and Environmental
| Protection Rating |
IP65, IP66, IP67 (conforms to EN 60529) |
| Operating Temperature |
0 to +55 degC |
| Storage Temperature |
-25 to +85 degC |
| Vibration and Shock Resistance |
Conforms to EN 60068-2-6 and EN 60068-2-27 |
| EMC Immunity and Emission |
Conforms to EN 61000-6-2 and EN 61000-6-4 |
| Installation Position |
Variable |
| Approvals |
CE, UL |
Connections / Interfaces
| Interface |
Function |
| M12 Socket (5-pin, B-coded) |
PROFIBUS DP fieldbus communication connection |
| M8 Male Connector (4-pin) |
24 V DC control voltage input feed |
| M8 Female Connector (4-pin) |
24 V DC downstream control voltage loop-through |
Installation Guidelines
-
System De-energization: Prior to mounting, installation, or wiring, ensure all electrical power sources to the system are completely switched off.
-
Physical Mounting: Securely mount the module directly to the machine frame or mounting plate using the integrated mounting holes. Ensure the surface is flat to avoid stress on the housing.
-
Fieldbus Connection: Connect the PROFIBUS DP line to the B-coded M12 interface. Properly tighten the connector collar to ensure an IP67 environmental seal.
-
Power Supply Connection: Feed the 24 V DC control voltage into the M8 male connector. If daisy-chaining power, connect the downstream M8 female connector to the next fieldbus box.
-
Grounding: Ensure proper grounding through the mounting screws or a dedicated ground connection to prevent electromagnetic interference.
-
Commissioning Check: Apply power and observe the status LEDs to verify communication and operating state.