BECKHOFF

BECKHOFF KL4004 Bus Terminal

SKU KL4004

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: KL4004

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 85g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF KL4004 is a 4-channel analog output Bus Terminal designed to generate high-precision control signals in the range of 0 to 10 V. Operating within the modular Beckhoff Bus Terminal system, this terminal serves as a reliable interface between automation control systems and physical analog actuators such as speed drives, valves, and setpoint adjusters.

Signals are processed and output with a 12-bit resolution, ensuring stable and accurate control. The BECKHOFF KL4004 features a single-ended circuit design and does not feature power contacts, meaning its internal electronics are powered entirely via the K-bus. It also provides 500 V of electrical isolation between the internal K-bus and the analog signal voltage to protect sensitive control electronics.

Features

  • Four analog output channels supporting 0 to 10 V signals.
  • 12-bit resolution for precise analog control loops.
  • Short-circuit proof outputs with load resistance handling greater than 5 kOhm.
  • Internal galvanic isolation of 500 V between the K-bus and the output channels.
  • Compact, space-saving terminal housing with integrated status LEDs.
  • No power contacts, drawing current exclusively from the K-bus.

Applications

  • Speed control for frequency converters and servo drives.
  • Analog valve position control in fluid power and HVAC systems.
  • Setpoint adjustment in testing and calibration stations.
  • Distributed industrial control systems using Beckhoff Bus Couplers.

Technical Specifications

General

Manufacturer BECKHOFF
Model KL4004
Product Type Bus Terminal (Analog Output)
Number of Outputs 4
Technology Single-ended

Signal and I/O

Signal Voltage 0 to 10 V
Resolution 12 bit
Conversion Time approx. 2 ms
Load Resistance > 5 kOhm (short-circuit proof)
Output Error < ±0.1% (relative to end value)

Electrical

Power Supply Via K-bus
K-bus Current Consumption typ. 85 mA
Power Contacts Current Consumption None (no power contacts)
Electrical Isolation 500 V (K-bus to signal voltage)
Bit Width in Process Image Output: 4 x 16 bit data (4 x 8 bit control/status optional)

Mechanical and Connection

Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight approx. 85 g
Mounting 35 mm DIN rail (EN 60715) with lock
Wiring Technology Cage Clamp (solid, flexible, or ferrule)
Solid/Stranded Conductor Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Flexible Conductor Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm

Environmental and Compliance

Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE, UL, ATEX
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. Ensure the entire control system and associated power supplies are fully de-energized before beginning installation or removal.
  2. Mount the terminal onto a standard 35 mm DIN rail (EN 60715) by sliding it into place until the locking mechanism clicks securely.
  3. Connect the terminal side-by-side with other Bus Terminals using the integrated slot-and-key system, ensuring physical and electrical contact with the K-bus.
  4. Strip the signal wire insulation to a length of 8 to 9 mm.
  5. Insert a small screwdriver into the operating slot of the cage clamp to open the wire clamp, insert the conductor, and release to secure.
  6. Note that the terminal has no power contacts; no power is fed through the adjacent terminals. Ensure appropriate field ground or external supply routing for connected analog devices.

FAQ

What is the primary function of the BECKHOFF KL4004?

The BECKHOFF KL4004 is a 4-channel analog output Bus Terminal designed to generate stable analog voltage signals from 0 to 10 V with a 12-bit resolution for precise control loop operations.

Does the BECKHOFF KL4004 require a connection to power contacts?

No, the BECKHOFF KL4004 has no power contacts and draws its operating power exclusively from the K-bus, with a typical current consumption of 85 mA.

Is the BECKHOFF KL4004 certified for use in hazardous areas?

Yes, the BECKHOFF KL4004 is ATEX certified with the marking II 3 G Ex nA IIC T4 Gc, allowing it to be safely installed in Zone 2 hazardous areas.

What is the electrical isolation capability of the BECKHOFF KL4004?

The BECKHOFF KL4004 provides galvanic isolation of 500 V between the internal K-bus logic circuits and the analog output signal voltage to protect against noise and voltage surges.

What type of load can be connected to the BECKHOFF KL4004 outputs?

The BECKHOFF KL4004 outputs are designed to connect to analog loads greater than 5 kOhm and feature built-in short-circuit protection.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.