BECKHOFF

BECKHOFF KM1018-0002 Bus Terminal Module

SKU KM1018-0002

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: KM1018-0002

  • Country of origin:Germany

  • Product Type: Bus Terminal Modules

  • Payment: T/T, Western Union

  • Weight: 310g

  • Dimensions: 123 mm x 100 mm x 55 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The BECKHOFF KM1018-0002 is a high-density, compact Bus Terminal module designed for processing up to 64 digital input signals from the field level within industrial automation environments. By grouping multiple channels into a single highly efficient housing, this terminal module optimizes space utilization within control cabinets while maintaining reliable system integration with standard K-bus I/O architectures.

This specific variant, the KM1018-0002, features 1-wire connection technology complete with integrated status LEDs, allowing for localized diagnostics at each of the 64 channel connection points. The control signals are transmitted with electrical isolation from the field potential to the higher-level automation unit, ensuring reliable operation in demanding environments.

Features

  • High-density processing of 64 digital input channels in a single terminal housing.
  • 1-wire connection technology with integrated diagnostic status LEDs for rapid troubleshooting.
  • Electrical isolation of 500 V between the K-bus and the field potential.
  • Pluggable wiring level interface for simplified installation and quick physical replacements.
  • Compact design form factor engineered for mounting on standard DIN rails.

Applications

  • High-channel count digital signal collection in space-restricted control cabinets.
  • Industrial machine control and localized manufacturing automation setups.
  • Distributed I/O processing integrated with standard Beckhoff K-bus couplers.

Technical Specifications

General and Physical

Parameter Specification
Manufacturer BECKHOFF
Exact Model KM1018-0002
Product Type Bus Terminal Module
Design Form Compact terminal module with pluggable wiring level
Dimensions (W x H x D) 123 mm x 100 mm x 55 mm
Mounting 35 mm DIN rail (EN 60715) with lock
Weight Approx. 310 g to 390 g depending on connector type
Protection Class IP20

Signal and Electrical

Parameter Specification
Number of Inputs 64
Connection Technology 1-wire pluggable connector with LEDs
Nominal Voltage 24 V DC (-15% / +20%)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 15 to 30 V
Current Consumption K-bus Typ. 3 mA
Electrical Isolation 500 V (K-bus / field potential)
Process Image Bit Width 64 inputs
Conductor Cross-section 0.08 to 1.5 mm² (stranded or solid wire)
Stripping Length 8 mm

Environmental and Standards

Parameter Specification
Operating Temperature 0 to +55 degrees Celsius
Storage Temperature -25 to +85 degrees Celsius
Relative Humidity 95%, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals and Markings CE

Installation Guidelines

  1. System De-energization: Prior to starting any installation, mounting, or wiring procedures, isolate and switch off the power supply to the entire control cabinet.
  2. DIN Rail Mounting: Securely clip the terminal block onto a standard 35 mm DIN rail (EN 60715) using the integrated lock system. Ensure a rigid mechanical fit using the double slot and key connection for side-by-side assembly.
  3. Wiring and Connectors: Strip input conductors to a length of 8 mm. Insert wires ranging from 0.08 to 1.5 mm² into the pluggable 1-wire connector block.
  4. Status Check: Restore system power and observe the channel-specific status LEDs to confirm logical status changes of the 64 input signals during commissioning.

FAQ

What connection style does the BECKHOFF KM1018-0002 utilize?

The BECKHOFF KM1018-0002 utilizes a 1-wire pluggable connection system that includes integrated status LEDs for localized diagnostic feedback on all 64 input channels.

Are address settings required during the installation of the BECKHOFF KM1018-0002?

No, the BECKHOFF KM1018-0002 does not require manual address or hardware configuration settings, integrating directly into the standard K-bus process image.

What level of electrical isolation is provided by the BECKHOFF KM1018-0002?

The BECKHOFF KM1018-0002 features 500 V of electrical isolation between the internal K-bus and the external field potential to protect sensitive control electronics.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.