The BECKHOFF KS6811 is a specialized single-channel DALI/DSI master Bus Terminal designed to integrate digital lighting control interfaces directly into standard Beckhoff I/O networks. This terminal serves as an intelligent bridge, enabling bidirectional communication between a central automation controller and lighting components such as electronic ballasts, dimmers, and control gears. It features a pluggable wiring design that simplifies field installation, maintenance, and system upgrades by allowing the wiring block to be removed as a single unit without disconnecting individual conductors.

The KS6811 terminal features a built-in DALI power supply capable of delivering up to 130 mA, which simplifies installation by removing the need for an external bus power source in standard layouts. With a process image of 3 bytes of input and 3 bytes of output data, the terminal provides the communication throughput required for complex lighting commands, dimming curves, and status diagnostics. It operates as a master controller, supporting up to 64 DALI slaves and up to 16 groups, ensuring flexible network layouts in professional lighting automation.

Features

  • Single-channel master interface supporting both DALI and DSI lighting control protocols.
  • Direct integration of up to 64 DALI slaves and 16 configurable groups.
  • Integrated DALI bus power supply delivering up to 130 mA with open-circuit protection.
  • Pluggable connection level (KS series design) for efficient installation, wiring prep, and terminal replacement.
  • Standardized bidirectional data transfer rate of 1200 baud for reliable DALI signaling.
  • Comprehensive electrical isolation between the K-bus and DALI-bus to protect control-side electronics.
  • Full configuration capability via the host Bus Coupler or automation controller.
  • Direct software integration using the TwinCAT PLC DALI library.

Applications

  • Commercial building automation, including automated office and retail lighting.
  • Industrial lighting integration and centralized facility lighting management.
  • Daylight harvesting systems, occupancy-based light control, and dimming networks.
  • Integration of electronic control gears (ECG) and ballast units in assembly environments.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KS6811
Product Type Bus Terminal (Pluggable Wiring Level)
Signal/Technology DALI/DSI Master
Number of Channels 1
Data Transfer Rate 1200 baud
Process Image Bit Width Input: 3 bytes; Output: 3 bytes

Electrical

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
Input Voltage 24 V DC (-15% / +20%)
Current Consumption (K-bus) Typically 55 mA
Current Consumption (Power Contacts) Typically 30 mA + load
DALI Power Supply Maximum 130 mA (open-circuit voltage 11.5 V to 15 V DC)
Electrical Isolation 500 V (K-bus / DALI-bus)
Insulation Voltage (DALI-bus to K-bus) 1,500 V DC
Insulation Voltage (DALI-bus to Power Contacts) 1,500 V DC
Surge Voltage Resistance Constant load 275 V AC rms
Current Load Power Contacts Maximum 10 A

Mechanical

Parameter Specification
Dimensions (W x H x D) 15 mm x 100 mm x 70 mm
Weight Approximately 80 g
Wiring Technology Solid, flexible, or ferruled conductors; spring actuation via screwdriver
Connection Cross-Section (Solid/Stranded) 0.08 mm² to 1.5 mm² (AWG 28 to 16)
Connection Cross-Section (Flexible) 0.14 mm² to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 mm to 10 mm
Mounting 35 mm DIN rail (EN 60715) with lock
Side-by-Side Mounting Double slot and key connection
Housing Material Polycarbonate

Environmental and Compliance

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20 (variable installation position)
Approvals and Markings CE, cULus, ATEX
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. De-energize the System: Turn off all electrical power supplies to the DIN rail and the surrounding components before installing, removing, or wiring the module.
  2. Mount the Terminal: Snap the KS6811 Bus Terminal onto a standard 35 mm DIN rail conforming to EN 60715, ensuring the double slot and key system aligns perfectly with the adjacent terminals. Lock the integrated rail release mechanism.
  3. Prepare and Connect Wiring: Remove the pluggable wiring connector block if necessary for ease of access. Strip conductors to a length of 9 to 10 mm. Actuate the tension clamp with a small flat-head screwdriver, insert the conductor, and release to secure. Re-seat the connector block firmly onto the terminal housing.
  4. Connect the DALI Bus: Connect the DALI bus wires to the designated terminal points. Check polarity and verify the network configuration does not exceed 64 slaves.
  5. Verify Power and Grounding: Ensure the 24 V DC feed to the power contacts and K-bus supply are within the specified limits before applying power.
  6. Commissioning: Power up the system and verify the statuses of the integrated diagnostic indicators, then use TwinCAT or your preferred bus controller tool to scan and configure the connected DALI devices.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF KS6811 Bus Terminal?
The BECKHOFF KS6811 is a single-channel DALI/DSI master terminal designed to integrate digital lighting control components (such as electronic ballasts, dimmers, and control gears) directly into a Beckhoff Bus Terminal I/O network, supporting up to 64 DALI slaves and 16 groups.
How does the pluggable wiring of the KS6811 model benefit maintenance and installation?
The BECKHOFF KS6811 features a pluggable connection level that allows the entire wiring block to be removed as a single unit without disconnecting individual field lines, facilitating rapid terminal replacement and streamlined pre-wiring.
Does the KS6811 require an external power supply for the DALI bus?
No, the BECKHOFF KS6811 features an integrated DALI power supply providing a maximum current of 130 mA, which is typically sufficient to power the connected DALI bus and local slaves without requiring an additional external power supply.
What software library is used to configure and control the KS6811?
The BECKHOFF KS6811 terminal is configured and programmed through the standard controller or Bus Coupler using the specialized TwinCAT PLC DALI library.
What are the electrical isolation characteristics of the KS6811?
The BECKHOFF KS6811 provides 500 V of electrical isolation between the K-bus and the DALI-bus, alongside an insulation voltage rating of 1,500 V DC between the DALI-bus and the K-bus, and between the DALI-bus and power contacts.
Reviews

KS6811

Stock & lead time on request

Call
1 of 1

BECKHOFF KS6811 DALI/DSI Master Bus Terminal with Pluggable Wiring

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS6811

  • Country of origin:Germany

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 80g

  • Dimensions: 15 mm x 100 mm x 70 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KS6811 is a specialized single-channel DALI/DSI master Bus Terminal designed to integrate digital lighting control interfaces directly into standard Beckhoff I/O networks. This terminal serves as an intelligent bridge, enabling bidirectional communication between a central automation controller and lighting components such as electronic ballasts, dimmers, and control gears. It features a pluggable wiring design that simplifies field installation, maintenance, and system upgrades by allowing the wiring block to be removed as a single unit without disconnecting individual conductors.

The KS6811 terminal features a built-in DALI power supply capable of delivering up to 130 mA, which simplifies installation by removing the need for an external bus power source in standard layouts. With a process image of 3 bytes of input and 3 bytes of output data, the terminal provides the communication throughput required for complex lighting commands, dimming curves, and status diagnostics. It operates as a master controller, supporting up to 64 DALI slaves and up to 16 groups, ensuring flexible network layouts in professional lighting automation.

Features

  • Single-channel master interface supporting both DALI and DSI lighting control protocols.
  • Direct integration of up to 64 DALI slaves and 16 configurable groups.
  • Integrated DALI bus power supply delivering up to 130 mA with open-circuit protection.
  • Pluggable connection level (KS series design) for efficient installation, wiring prep, and terminal replacement.
  • Standardized bidirectional data transfer rate of 1200 baud for reliable DALI signaling.
  • Comprehensive electrical isolation between the K-bus and DALI-bus to protect control-side electronics.
  • Full configuration capability via the host Bus Coupler or automation controller.
  • Direct software integration using the TwinCAT PLC DALI library.

Applications

  • Commercial building automation, including automated office and retail lighting.
  • Industrial lighting integration and centralized facility lighting management.
  • Daylight harvesting systems, occupancy-based light control, and dimming networks.
  • Integration of electronic control gears (ECG) and ballast units in assembly environments.

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KS6811
Product Type Bus Terminal (Pluggable Wiring Level)
Signal/Technology DALI/DSI Master
Number of Channels 1
Data Transfer Rate 1200 baud
Process Image Bit Width Input: 3 bytes; Output: 3 bytes

Electrical

Parameter Specification
Nominal Voltage 24 V DC (-15% / +20%)
Input Voltage 24 V DC (-15% / +20%)
Current Consumption (K-bus) Typically 55 mA
Current Consumption (Power Contacts) Typically 30 mA + load
DALI Power Supply Maximum 130 mA (open-circuit voltage 11.5 V to 15 V DC)
Electrical Isolation 500 V (K-bus / DALI-bus)
Insulation Voltage (DALI-bus to K-bus) 1,500 V DC
Insulation Voltage (DALI-bus to Power Contacts) 1,500 V DC
Surge Voltage Resistance Constant load 275 V AC rms
Current Load Power Contacts Maximum 10 A

Mechanical

Parameter Specification
Dimensions (W x H x D) 15 mm x 100 mm x 70 mm
Weight Approximately 80 g
Wiring Technology Solid, flexible, or ferruled conductors; spring actuation via screwdriver
Connection Cross-Section (Solid/Stranded) 0.08 mm² to 1.5 mm² (AWG 28 to 16)
Connection Cross-Section (Flexible) 0.14 mm² to 1.5 mm² (AWG 26 to 16)
Stripping Length 9 mm to 10 mm
Mounting 35 mm DIN rail (EN 60715) with lock
Side-by-Side Mounting Double slot and key connection
Housing Material Polycarbonate

Environmental and Compliance

Parameter Specification
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, no condensation
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20 (variable installation position)
Approvals and Markings CE, cULus, ATEX
Ex Marking II 3 G Ex nA IIC T4 Gc

Installation Guidelines

  1. De-energize the System: Turn off all electrical power supplies to the DIN rail and the surrounding components before installing, removing, or wiring the module.
  2. Mount the Terminal: Snap the KS6811 Bus Terminal onto a standard 35 mm DIN rail conforming to EN 60715, ensuring the double slot and key system aligns perfectly with the adjacent terminals. Lock the integrated rail release mechanism.
  3. Prepare and Connect Wiring: Remove the pluggable wiring connector block if necessary for ease of access. Strip conductors to a length of 9 to 10 mm. Actuate the tension clamp with a small flat-head screwdriver, insert the conductor, and release to secure. Re-seat the connector block firmly onto the terminal housing.
  4. Connect the DALI Bus: Connect the DALI bus wires to the designated terminal points. Check polarity and verify the network configuration does not exceed 64 slaves.
  5. Verify Power and Grounding: Ensure the 24 V DC feed to the power contacts and K-bus supply are within the specified limits before applying power.
  6. Commissioning: Power up the system and verify the statuses of the integrated diagnostic indicators, then use TwinCAT or your preferred bus controller tool to scan and configure the connected DALI devices.
Loading product navigation…

What is the primary function of the BECKHOFF KS6811 Bus Terminal?

The BECKHOFF KS6811 is a single-channel DALI/DSI master terminal designed to integrate digital lighting control components (such as electronic ballasts, dimmers, and control gears) directly into a Beckhoff Bus Terminal I/O network, supporting up to 64 DALI slaves and 16 groups.

How does the pluggable wiring of the KS6811 model benefit maintenance and installation?

The BECKHOFF KS6811 features a pluggable connection level that allows the entire wiring block to be removed as a single unit without disconnecting individual field lines, facilitating rapid terminal replacement and streamlined pre-wiring.

Does the KS6811 require an external power supply for the DALI bus?

No, the BECKHOFF KS6811 features an integrated DALI power supply providing a maximum current of 130 mA, which is typically sufficient to power the connected DALI bus and local slaves without requiring an additional external power supply.

What software library is used to configure and control the KS6811?

The BECKHOFF KS6811 terminal is configured and programmed through the standard controller or Bus Coupler using the specialized TwinCAT PLC DALI library.

What are the electrical isolation characteristics of the KS6811?

The BECKHOFF KS6811 provides 500 V of electrical isolation between the K-bus and the DALI-bus, alongside an insulation voltage rating of 1,500 V DC between the DALI-bus and the K-bus, and between the DALI-bus and power contacts.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...