BECKHOFF

BECKHOFF KS9508 Bus Terminal Power Supply Terminal 8 V DC

SKU KS9508

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: KS9508
  • Origin Germany
  • Product Type: Power Supply Terminals
  • Payment: T/T, Western Union
  • Weight: 0.065 kg
  • Dimensions: 6.8 cm x 1.2 cm x 10.0 cm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The BECKHOFF KS9508 is a Bus Terminal designed to provide a stabilized 8 V DC output voltage within modular I/O system architectures. Operating on a 24 V DC input voltage, this power supply terminal supplies regulated power to specialized electronic loads and internal bus terminal circuits requiring a tightly controlled 8 V DC supply. It integrates into modular terminal assemblies, featuring pluggable wiring and standard DIN rail mounting.

Equipped with short-circuit protection and a stabilized output, the KS9508 ensures operational safety and voltage integrity for connected field devices. Diagnostic capabilities include an overcurrent LED indicator for status monitoring. The terminal housing is constructed from polycarbonate and supports side-by-side installation alongside other KSxxxx series bus terminals using a double slot and key connection method.

Features

  • Stabilized 8 V DC output voltage with a 1 percent tolerance
  • Nominal output current capacity of 0.5 A
  • 24 V DC input voltage range with -15 percent to +20 percent tolerance
  • Short-circuit proof output design
  • Overcurrent LED indicator for diagnostic status
  • Pluggable wiring level compatible with KSxxxx Bus Terminals
  • Polycarbonate terminal housing design for standard DIN rail installation

Applications

  • Power distribution for specialized electronic field devices requiring an 8 V DC supply
  • Modular industrial automation systems utilizing KSxxxx series bus terminals
  • Control cabinet installations requiring isolated or regulated subsidiary voltage levels

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KS9508
Product Type Power Supply Terminal
Design Form Terminal housing with pluggable wiring level
Housing Material Polycarbonate

Electrical

Parameter Specification
Input Voltage 24 V DC (-15 percent / +20 percent)
Output Voltage 8 V DC (+/- 1 percent)
Output Current 0.5 A
Residual Ripple < 5 mV
Short-Circuit Proof Yes
Current Load Power Contacts Imax: 10 A

Connection Technology

Parameter Specification
Wiring Method Spring actuation by screwdriver
Connection Cross-Section Solid (s) 0.08 to 1.5 mm²
Connection Cross-Section Stranded (st) 0.08 to 1.5 mm²
Connection Cross-Section Fine-Stranded (f) 0.14 to 1.5 mm²
Connection Cross-Section AWG AWG 28 to 16 (s, st), AWG 26 to 16 (f)
Stripping Length 9 to 10 mm

Mechanical and Environmental

Parameter Specification
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Net Weight 0.065 kg
Mounting 35 mm DIN rail conforming to EN 60715 with lock
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 percent, no condensation
Protection Rating IP20

Installation Guidelines

  1. Ensure all power supplies and field voltage sources are switched off and verified de-energized before beginning installation or wiring work.
  2. Inspect the KS9508 terminal housing and pluggable connectors for any visible transit damage or defects.
  3. Mount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715) by snapping it securely into place with the locking mechanism.
  4. Interlock the terminal side-by-side with adjacent KSxxxx series bus terminals using the double slot and key connection.
  5. Strip conductors to the specified length of 9 to 10 mm.
  6. Connect the 24 V DC input supply and output lines using a suitable screwdriver for spring actuation, ensuring secure clamping according to the approved cross-section ranges.
  7. Verify terminal assignments, potential supply connections, and polarity before restoring power to the system.
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the output voltage and current of the BECKHOFF KS9508?
The BECKHOFF KS9508 provides a stabilized output voltage of 8 V DC within a +/- 1 percent tolerance and delivers a nominal output current of 0.5 A.
What input voltage does the BECKHOFF KS9508 require?
The BECKHOFF KS9508 operates from a 24 V DC input voltage with an allowable tolerance range of -15 percent to +20 percent.
How is the BECKHOFF KS9508 mounted into an automation system?
The BECKHOFF KS9508 mounts onto a standard 35 mm DIN rail conforming to EN 60715 and connects side-by-side with other KSxxxx series bus terminals using a double slot and key mechanism.
What diagnostic features are built into the BECKHOFF KS9508?
The BECKHOFF KS9508 includes short-circuit protection and an overcurrent LED indicator to signal fault conditions and operational status.
Reviews

KS9508

Stock &amp; lead time on request

Call
1 of 1

BECKHOFF KS9508 Bus Terminal Power Supply Terminal 8 V DC

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS9508

  • Country of origin:Germany

  • Product Type: Power Supply Terminals

  • Payment: T/T, Western Union

  • Weight: 65g

  • Dimensions: 6.8 cm x 1.2 cm x 10.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The BECKHOFF KS9508 is a Bus Terminal designed to provide a stabilized 8 V DC output voltage within modular I/O system architectures. Operating on a 24 V DC input voltage, this power supply terminal supplies regulated power to specialized electronic loads and internal bus terminal circuits requiring a tightly controlled 8 V DC supply. It integrates into modular terminal assemblies, featuring pluggable wiring and standard DIN rail mounting.

Equipped with short-circuit protection and a stabilized output, the KS9508 ensures operational safety and voltage integrity for connected field devices. Diagnostic capabilities include an overcurrent LED indicator for status monitoring. The terminal housing is constructed from polycarbonate and supports side-by-side installation alongside other KSxxxx series bus terminals using a double slot and key connection method.

Features

  • Stabilized 8 V DC output voltage with a 1 percent tolerance
  • Nominal output current capacity of 0.5 A
  • 24 V DC input voltage range with -15 percent to +20 percent tolerance
  • Short-circuit proof output design
  • Overcurrent LED indicator for diagnostic status
  • Pluggable wiring level compatible with KSxxxx Bus Terminals
  • Polycarbonate terminal housing design for standard DIN rail installation

Applications

  • Power distribution for specialized electronic field devices requiring an 8 V DC supply
  • Modular industrial automation systems utilizing KSxxxx series bus terminals
  • Control cabinet installations requiring isolated or regulated subsidiary voltage levels

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model KS9508
Product Type Power Supply Terminal
Design Form Terminal housing with pluggable wiring level
Housing Material Polycarbonate

Electrical

Parameter Specification
Input Voltage 24 V DC (-15 percent / +20 percent)
Output Voltage 8 V DC (+/- 1 percent)
Output Current 0.5 A
Residual Ripple < 5 mV
Short-Circuit Proof Yes
Current Load Power Contacts Imax: 10 A

Connection Technology

Parameter Specification
Wiring Method Spring actuation by screwdriver
Connection Cross-Section Solid (s) 0.08 to 1.5 mm²
Connection Cross-Section Stranded (st) 0.08 to 1.5 mm²
Connection Cross-Section Fine-Stranded (f) 0.14 to 1.5 mm²
Connection Cross-Section AWG AWG 28 to 16 (s, st), AWG 26 to 16 (f)
Stripping Length 9 to 10 mm

Mechanical and Environmental

Parameter Specification
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Net Weight 0.065 kg
Mounting 35 mm DIN rail conforming to EN 60715 with lock
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95 percent, no condensation
Protection Rating IP20

Installation Guidelines

  1. Ensure all power supplies and field voltage sources are switched off and verified de-energized before beginning installation or wiring work.
  2. Inspect the KS9508 terminal housing and pluggable connectors for any visible transit damage or defects.
  3. Mount the terminal onto a standard 35 mm DIN rail (conforming to EN 60715) by snapping it securely into place with the locking mechanism.
  4. Interlock the terminal side-by-side with adjacent KSxxxx series bus terminals using the double slot and key connection.
  5. Strip conductors to the specified length of 9 to 10 mm.
  6. Connect the 24 V DC input supply and output lines using a suitable screwdriver for spring actuation, ensuring secure clamping according to the approved cross-section ranges.
  7. Verify terminal assignments, potential supply connections, and polarity before restoring power to the system.
Loading product navigation…

What is the output voltage and current of the BECKHOFF KS9508?

The BECKHOFF KS9508 provides a stabilized output voltage of 8 V DC within a +/- 1 percent tolerance and delivers a nominal output current of 0.5 A.

What input voltage does the BECKHOFF KS9508 require?

The BECKHOFF KS9508 operates from a 24 V DC input voltage with an allowable tolerance range of -15 percent to +20 percent.

How is the BECKHOFF KS9508 mounted into an automation system?

The BECKHOFF KS9508 mounts onto a standard 35 mm DIN rail conforming to EN 60715 and connects side-by-side with other KSxxxx series bus terminals using a double slot and key mechanism.

What diagnostic features are built into the BECKHOFF KS9508?

The BECKHOFF KS9508 includes short-circuit protection and an overcurrent LED indicator to signal fault conditions and operational status.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosing 24 VDC Power Supplies Without Chasing Ghost Faults

A dead control cabinet does not automatically mean a failed power supply. This field guide uses input, no-load, loaded, ripple, wiring, and protection checks to separate source faults from downstream...

A Practical Signal Chain for Industrial Measurement and Control

Reliable control begins before the PLC executes a loop. This engineering guide follows the signal chain from sensing and conditioning to transmission, control action, final elements, calibration, and...

Modbus on Plant Networks: Frames, Registers, and Design Limits

Modbus remains widely deployed because its data model is simple, not because every implementation is simple. This guide explains frames, register mapping, timing, diagnostics, and the design limits...

Inside the PLC CPU: Scan Cycles, Memory, and Selection

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.