Bently Nevada

Bently Nevada 126599-01 3500/44M Aero GT I/O Module

SKU 126599-01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 126599-01

  • Country of origin:United States

  • Product Type: Aero GT I/O Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 2.3cm x 11cm x 24.1cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The 126599-01 is an Aero GT I/O module with internal terminations manufactured by Bently Nevada for the 3500/44M Aeroderivitive GT Vibration Monitor. Installed in a full-height rear slot of a 3500 rack, the 126599-01 accepts input signals from interface modules (part numbers 86517 and 86497), Velomitors, and accelerometers to monitor aeroderivative gas turbine machinery. The module operates in conjunction with the 3500/44M main monitor module, accepting inputs from two separate Keyphasor signals and routing signals for 1X vibration tracking, band-pass vibration, and signal integration. It includes internal termination connections for transducer inputs, recorder outputs, and inhibit controls.

Features

  • Full-height rear I/O module with internal termination wiring headers
  • Interfaces with interface modules (PN 86517 and 86497), Velomitors, and accelerometers
  • Routes input signals for aeroderivative gas turbine monitoring applications
  • Supports dual Keyphasor signal inputs across channel pairs
  • Connects directly to the 3500/44M Aeroderivitive GT Vibration Monitor main board via the rack backplane

Applications

  • Aeroderivative gas turbine vibration monitoring
  • Machinery protection and automated alarm trip systems
  • Industrial gas turbine condition monitoring loops

Ordering Information

Part Number / Option Description
3500/44-AA-BB Aeroderivative Monitor
A: I/O Module Type  
01 Aero GT I/O Module with Internal Terminations
02 Aero GT I/O Module with External Terminations
05 Prox/Velom I/O Module with Internal Terminations
06 Prox/Velom I/O Module with External Terminations
07 Multimode Prox/Velom I/O Module with Internal Terminations
08 Multimode Prox/Velom I/O Module with External Terminations
B: Hazardous Area Approval Option  
00 None
01 cNRTLus (Class 1, Division 2)
02 ATEX/IECEx/CSA (Class 1, Zone 2)
Spares & Components  
126599-01 Aero GT I/O Module Internal Terminations
143490-01 3500/44M Aeroderivitive GT Vibration Monitor
143491-01 3500/44M Aeroderivitive GT Vibration Monitor User Guide
140471-01 Prox/Velom I/O Module with Internal Terminations
140482-01 Prox/Velom I/O Module with External Terminations
169459-01 Multimode Prox/Velom I/O Module with Internal Terminations
169459-02 Multimode Prox/Velom I/O Module with External Terminations
00580434 Euro Style connector header, 8 pin, Green
00580432 Euro Style connector header, 10 pin, Green
00561941 Prox/Velom and Multimode Prox/Velom I/O Module ten-pin connector shunt
166M2389 Connector Header Push-in-Spring Type (Alternative for PN 00580434)
166M2388 Connector Header Push-in-Spring Type (Alternative for PN 00580432)

Technical Specifications

Parameter Specification
Manufacturer Bently Nevada
Product Type Aero GT I/O Module with Internal Terminations
Input Signal Capacity Accepts 1 to 4 signals from interface modules (86517, 86497), Velomitors, and accelerometers
Input Impedance Greater than 95 kOhm (Proximitor and acceleration inputs)
Transducer Power Supply -23 Vdc nominal at 43 mA max
Recorder Voltage Compliance +4 to +20 mA (Output proportional to monitor full-scale; load resistance 0 to 600 Ohm, +12 Vdc range across load)
Rack Space Requirement 1 full-height rear slot
I/O Module Dimensions (H x W x D) 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
I/O Module Weight 0.45 kg (1.0 lb)

Connections/Interfaces

Connector Pin Function
PWR + Transducer Power Positive
PWR - Transducer Power Negative
SHLD Transducer Shield
COM Common
CH1 - CH4 Channel 1 through Channel 4 Transducer Inputs
INHB Inhibit Input
RET Return
REC1 - REC4 Recorder Outputs 1 through 4
SHIELD System Ground / Shield Connection

Installation Guidelines

  • Install the module into the full-height rear slot directly behind the 3500/44M main monitor board.
  • Secure field transducer and recorder wiring using compatible Euro-style connector headers or push-in spring terminal connectors.
  • Connect channel shield wires to the designated SHLD terminals on the I/O block.
  • Ensure proper insertion and torque on rear panel retaining screws to secure backplane ground connection.

Compliance and Certifications

  • FCC: Complies with part 15 of the FCC Rules
  • EMC: European Community Directive 2014/30/EU; Standards EN 61000-6-2, EN 61000-6-4
  • Electrical Safety: European Community Directive LV Directive 2014/35/EU; Standard EN 61010-1
  • RoHS: European Community Directive ROHS Directive 2011/65/EU
  • Maritime: DNV GL rules for classification; ABS Rules for Condition of Classification (Part 1, Steel Vessels Rules, Offshore Units and Structures)
  • cNRTLus (Without Internal Barriers): Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)
  • cNRTLus (With Internal Barriers): Class I, Zone 2: AEx/Ex nA nC ic [ia Ga] IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic [ia Ga] IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D (W/ IS Output for Division 1); T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)
  • ATEX/IECEx (Without Internal Barriers): Ex II 3 G; Ex nA nC ic IIC T4 Gc; Ex ec nC ic IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)
  • ATEX/IECEx (With Internal Barriers): Ex II (1) G; Ex nA nC ic [ia Ga] IIC T4 Gc; Ex ec nC ic [ia Ga] IIC T4 Gc; T4 @ Ta = -20 degC to +65 degC (-4 degF to +149 degF)

FAQ

What primary main module is compatible with the device?

It is designed to work as the rear I/O card for the 3500/44M Aeroderivitive GT Vibration Monitor in a 3500 rack.

How many rack slots does the module occupy?

It occupies one full-height rear slot in the 3500 system rack.

What transducer inputs are supported by the module?

It accepts 1 to 4 signals from interface modules (part numbers 86517 and 86497), Velomitors, and accelerometers.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 126599-01 3500/44M Aero GT I/O Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.