Description
Designed to interface directly with the 3500/15 power supply system, the Bently Nevada 133300-01 provides regulated low-voltage DC input capabilities to the 3500 machinery protection rack. This rear-mount module accepts 20 to 30 VDC and conditions the incoming primary power before routing it to the internal backplane. Engineered for high-reliability environments, it is crucial for maintaining continuous machinery monitoring and protecting critical rotating assets from unexpected power interruptions.
Features
- Seamless integration with the 3500/15 Low Voltage DC Power Supply.
- Supports fully redundant power configurations when configured with a secondary rear module.
- Heavy-duty terminal block connections designed to withstand industrial vibration.
- Built-in overcurrent protection and electromagnetic interference (EMI) filtering.
- Passive cooling design optimized for continuous rack operation.
Applications
- Steam and gas turbine vibration monitoring systems.
- Hydroelectric generator protection setups.
- Petrochemical plant compressor and pump safety racks.
- Heavy industrial power generation and distribution facilities.
Technical Specifications
| Manufacturer |
Bently Nevada |
| Part Number |
133300-01 |
| Series |
3500 Machinery Protection System |
| Module Type |
Low Voltage DC Power Input Module (LVDCI) |
| Input Voltage Range |
20 to 30 VDC |
| Compatible Front Supply |
3500/15 Low Voltage DC Power Supply Module |
| Mounting Location |
Rear chassis slot (half-height) |
| Operating Temperature |
-30 to +65 Celsius |
| Country of Origin |
USA |
| Shipping Weight (Calculated) |
1.50 kg (3.30 lbs) |
| Package Dimensions (Calculated) |
24.1 cm x 11.2 cm x 5.1 cm |
Connections and Interfaces
| Terminal Block Pin |
Function / Circuit Assignment |
| Positive (+) |
+24 VDC Primary Input Power |
| Negative (-) |
DC Return / Common |
| Chassis Ground (GND) |
System / Earth Ground connection for shield continuity |
Empirical Engineering Insights
Alternative Models & Compatibility
The 133300-01 is specifically paired with the low-voltage DC variant of the 3500/15 power supply. It is physically and electrically incompatible with the high-voltage AC/DC modules (such as 129767-01 or 120739-01). Always verify the voltage rating of your front-facing 3500/15 module before hot-swapping or replacing rear input elements.
Application Pitfalls & Engineering Notes
In dual-redundant setups, ensure both low-voltage DC sources originate from independent breakers or power feeds. If both inputs are tied to the same feeder circuit, the system redundancy is effectively bypassed. Avoid routing raw, unfiltered field DC directly to these terminals; use external line conditioning if long cable runs are subject to inductive switching noise.
Commissioning & Wiring Tips
Use a minimum wire gauge of 14 AWG (2.1 mm2) to prevent excessive voltage drop over runs exceeding 10 meters. Ensure terminal block screws are torqued exactly to 0.56 Nm (5 in-lb) to maintain secure connections under continuous high-frequency machinery vibration.
Installation Guidelines
CRITICAL WARNING
De-energize all primary DC power feeds before installing, removing, or wiring the rear input module. Servicing connections while energized can cause dangerous electrical arcing, localized contact damage, or critical backplane component degradation.
1
Ensure the main 3500 rack power switch is in the OFF position and the source DC breaker is locked out.
2
Align the 133300-01 module card edges with the card guides in the designated rear half-height slot.
3
Slide the module firmly forward until its connector mates completely with the backplane connectors.
4
Secure the captive faceplate mounting screws and attach the terminal cover after finalizing field wiring.